Volumn 12, Issue 2, 2007, Pages 175-178

A comparison of conventional tube test and gel technique in evaluation of direct antiglobulin test

Author keywords

Autoantibody; Autoimmune hemolytic anemia; Direct antiglobulin test; Gel test; Immunohematology

Indexed keywords

IMMUNOGLOBULIN G;

EID: 34247231028     PISSN: 10245332     EISSN: 16078454     Source Type: Journal    
DOI: 10.1080/10245330601111862     Document Type: Article
Times cited : (15)

References (15)
  • 2
    • 34848878141 scopus 로고
    • A new test for the detection of weak and incomplete Rh agglutinins
    • Coombs, RRA, Mourant, AE and Race, RR (1945) A new test for the detection of weak and incomplete Rh agglutinins. Br J Exp Pathol, 26, p. 255.
    • (1945) Br J Exp Pathol , vol.26 , pp. 255
    • Coombs, R.R.A.1    Mourant, A.E.2    Race, R.R.3
  • 4
    • 0030989769 scopus 로고    scopus 로고
    • Comprison between conventional tube technique and gel technique in direct antiglobulin tests
    • Nathalang, O., Chuansunrit, A., Prayoonwiwat, W., Siripoonya, P. and Sriphaisal, T. (1997) Comprison between conventional tube technique and gel technique in direct antiglobulin tests. Vox Sang, 72, pp. 169-171.
    • (1997) Vox Sang , vol.72 , pp. 169-171
    • Nathalang, O.1    Chuansunrit, A.2    Prayoonwiwat, W.3    Siripoonya, P.4    Sriphaisal, T.5
  • 7
    • 0003809510 scopus 로고    scopus 로고
    • MD. American Association of Blood Banks, Bethesda, MD
    • Vengelen-Tyler, V. (1999) Technical manual, p. MD. American Association of Blood Banks, Bethesda, MD
    • (1999) Technical Manual
    • Vengelen-Tyler, V.1
  • 8
    • 0025057567 scopus 로고
    • The gel test: A new way to detect red cell antigen-antibody reactions
    • Lapierre, Y., Rigal, D., Adam, J., Josef, D., Meyer, F., Gerber, S. and Drot, C. (1990) The gel test: A new way to detect red cell antigen-antibody reactions. Transfusion, 30, pp. 109-113.
    • (1990) Transfusion , vol.30 , pp. 109-113
    • Lapierre, Y.1    Rigal, D.2    Adam, J.3    Josef, D.4    Meyer, F.5    Gerber, S.6    Drot, C.7
  • 9
    • 0034773049 scopus 로고    scopus 로고
    • Comparison of DATs using traditional tube agglutination to gel column and affinity column procedures
    • Dittmar, K., Procter, JL, Cipolone, K., Njorage, JM, Miller, J. and Stroncek, DF (2001) Comparison of DATs using traditional tube agglutination to gel column and affinity column procedures. Transfusion, 41, pp. 1258-1262.
    • (2001) Transfusion , vol.41 , pp. 1258-1262
    • Dittmar, K.1    Procter, J.L.2    Cipolone, K.3    Njorage, J.M.4    Miller, J.5    Stroncek, D.F.6
  • 10
    • 0015244477 scopus 로고
    • Red cell antibodies in acquired hemolytic anemia with negative antiglobulin serum tests
    • Gilliland, BC, Baxter, E. and Evans, RS (1971) Red cell antibodies in acquired hemolytic anemia with negative antiglobulin serum tests. N Engl J Med, 285, pp. 252-256.
    • (1971) N Engl J Med , vol.285 , pp. 252-256
    • Gilliland, B.C.1    Baxter, E.2    Evans, R.S.3
  • 13
    • 2942590636 scopus 로고    scopus 로고
    • The sensitivity, specificity and clinical relevance of gel versus tube DATs in the clinical immunology laboratory
    • Paz, N., Itzhaky, D. and Ellis, MH (2004) The sensitivity, specificity and clinical relevance of gel versus tube DATs in the clinical immunology laboratory. Immunohematology, 20, pp. 118-121.
    • (2004) Immunohematology , vol.20 , pp. 118-121
    • Paz, N.1    Itzhaky, D.2    Ellis, M.H.3
  • 14
    • 0033394872 scopus 로고    scopus 로고
    • Direct antiglobulin test: Still a place for tube technique?
    • Tissot, JD, Kiener, C., Burnard, B. and Schneider, P. (1999) Direct antiglobulin test: Still a place for tube technique?. Vox Sang, 77:4, pp. 223-226.
    • (1999) Vox Sang , vol.77 , Issue.4 , pp. 223-226
    • Tissot, J.D.1    Kiener, C.2    Burnard, B.3    Schneider, P.4
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.