메뉴 건너뛰기




Volumn 13, Issue 4, 2007, Pages 486-487

Do we need to MEND the MELD?

Author keywords

[No Author keywords available]

Indexed keywords

DISEASE SEVERITY; EDITORIAL; GRAFT SURVIVAL; HEALTH SURVEY; HUMAN; HYPERBILIRUBINEMIA; LIVER CELL CARCINOMA; LIVER FAILURE; LIVER FUNCTION TEST; LIVER TRANSPLANTATION; MATHEMATICAL MODEL; MORTALITY; PORTOSYSTEMIC ANASTOMOSIS; PREDICTION; PRIORITY JOURNAL; SCORING SYSTEM; STANDARDIZATION;

EID: 34247229189     PISSN: 15276465     EISSN: 15276473     Source Type: Journal    
DOI: 10.1002/lt.21040     Document Type: Editorial
Times cited : (10)

References (17)
  • 6
    • 4544300925 scopus 로고    scopus 로고
    • Specific laboratory methodologies achieve higher model for endstage liver disease (MELD) scores for patients listed for liver transplantation
    • Trotter JF, Brimhall B, Arjal R, Phillips C. Specific laboratory methodologies achieve higher model for endstage liver disease (MELD) scores for patients listed for liver transplantation. Liver Transpl 2004;10:995-1000.
    • (2004) Liver Transpl , vol.10 , pp. 995-1000
    • Trotter, J.F.1    Brimhall, B.2    Arjal, R.3    Phillips, C.4
  • 7
    • 3442882230 scopus 로고    scopus 로고
    • MELD underestimated unless enzymatic creatinine used
    • Bzowej NH, Huilgol VR, Sebanc H, Bonacini M, Rabkin J Doo, et al. MELD underestimated unless enzymatic creatinine used. J Hepatol 2004;40(Suppl 2):40.
    • (2004) J Hepatol , vol.40 , Issue.SUPPL. 2 , pp. 40
    • Bzowej, N.H.1    Huilgol, V.R.2    Sebanc, H.3    Bonacini, M.4    Doo, R.J.5
  • 9
    • 0018328497 scopus 로고
    • Bilirubin interference in kinetic creatinine determination
    • Dorwart WV. Bilirubin interference in kinetic creatinine determination. Clin Chem 1979;25:196-197.
    • (1979) Clin Chem , vol.25 , pp. 196-197
    • Dorwart, W.V.1
  • 10
    • 0018999198 scopus 로고
    • Kinetic serum creatinine assays. II. A critical evaluation and review
    • Bowers LD, Wong ET. Kinetic serum creatinine assays. II. A critical evaluation and review. Clin Chem 1980;26:555-561.
    • (1980) Clin Chem , vol.26 , pp. 555-561
    • Bowers, L.D.1    Wong, E.T.2
  • 11
    • 17944401013 scopus 로고
    • Serum separator tube problems in Hitachi 736/737 analyzers
    • Gerhardt G, Davitt C, Chan DW. Serum separator tube problems in Hitachi 736/737 analyzers. Clin Chem 1989; 36:1554.
    • (1989) Clin Chem , vol.36 , pp. 1554
    • Gerhardt, G.1    Davitt, C.2    Chan, D.W.3
  • 13
    • 0028235966 scopus 로고
    • Elimination of bilirubin interference in creatinine assays by routine techniques: Comparisons with a high performance liquid chromatography method
    • Boot S, LaRoche N, Legg EF. Elimination of bilirubin interference in creatinine assays by routine techniques: comparisons with a high performance liquid chromatography method. Ann Clin Biochem 1994;31:262-266.
    • (1994) Ann Clin Biochem , vol.31 , pp. 262-266
    • Boot, S.1    LaRoche, N.2    Legg, E.F.3
  • 16
    • 0025893319 scopus 로고
    • Interferences in current methods for measurements of creatinine
    • Weber JA, van Zanten AP. Interferences in current methods for measurements of creatinine. Clin Chem 1991;37: 695-700.
    • (1991) Clin Chem , vol.37 , pp. 695-700
    • Weber, J.A.1    van Zanten, A.P.2
  • 17
    • 33845491930 scopus 로고    scopus 로고
    • Model for End-Stage Liver Disease (MELD) exception guidelines
    • Weisner R, Lake JR, Freeman RB, Gish RG. Model for End-Stage Liver Disease (MELD) exception guidelines. Liver Transpl 2006; 12(Suppl 3):S85-S87.
    • (2006) Liver Transpl , vol.12 , Issue.SUPPL. 3
    • Weisner, R.1    Lake, J.R.2    Freeman, R.B.3    Gish, R.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.