-
1
-
-
0023706772
-
Biomechanical studies of running suture for flexor tendon repair in dogs
-
Lin G.T., An K.N., and Amadio P.C. Biomechanical studies of running suture for flexor tendon repair in dogs. J Hand Surg Am 13 (1988) 553-558
-
(1988)
J Hand Surg Am
, vol.13
, pp. 553-558
-
-
Lin, G.T.1
An, K.N.2
Amadio, P.C.3
-
2
-
-
0032856628
-
Current concepts review: rupture of the Achilles tendon
-
Maffulli N. Current concepts review: rupture of the Achilles tendon. J Bone Joint Surg 81A (1999) 1019-1036
-
(1999)
J Bone Joint Surg
, vol.81 A
, pp. 1019-1036
-
-
Maffulli, N.1
-
4
-
-
0031456595
-
Functional bracing for rupture of the Achilles tendon. Clinical results and analysis of ground-reaction forces and temporal data
-
McComis G.P., Nawoczenski D.A., and DeHaven K.E. Functional bracing for rupture of the Achilles tendon. Clinical results and analysis of ground-reaction forces and temporal data. J Bone Joint Surg 79A (1997) 1799-1808
-
(1997)
J Bone Joint Surg
, vol.79 A
, pp. 1799-1808
-
-
McComis, G.P.1
Nawoczenski, D.A.2
DeHaven, K.E.3
-
5
-
-
0036482903
-
Limited open repair of Achilles tendon ruptures: a technique with a new instrument and findings of a prospective multicenter study
-
Mathieu A., Maximillien J., Richard S., Pascal R., Marino D., and Pierre H. Limited open repair of Achilles tendon ruptures: a technique with a new instrument and findings of a prospective multicenter study. J Bone Joint Surg Am 84 (2002) 161-170
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 161-170
-
-
Mathieu, A.1
Maximillien, J.2
Richard, S.3
Pascal, R.4
Marino, D.5
Pierre, H.6
-
6
-
-
0025822196
-
Achilles tendon repair: a new method of Achilles tendon repair tested on cadaverous materials
-
Mortensen M.H., and Saether J. Achilles tendon repair: a new method of Achilles tendon repair tested on cadaverous materials. J Trauma 31 (1991) 381-384
-
(1991)
J Trauma
, vol.31
, pp. 381-384
-
-
Mortensen, M.H.1
Saether, J.2
-
7
-
-
0019451081
-
Surgical and non-surgical treatment of Achilles tendon ruptures. A prospective randomized study
-
Nistor L. Surgical and non-surgical treatment of Achilles tendon ruptures. A prospective randomized study. J Bone Joint Surg 63A (1981) 394-399
-
(1981)
J Bone Joint Surg
, vol.63 A
, pp. 394-399
-
-
Nistor, L.1
-
8
-
-
0027932247
-
Mechanical analysis of tendon suture techniques
-
Greenwald D.P., Hong Z.H., and Mag J.W. Mechanical analysis of tendon suture techniques. J Hand Surg 19A (1994) 641-647
-
(1994)
J Hand Surg
, vol.19 A
, pp. 641-647
-
-
Greenwald, D.P.1
Hong, Z.H.2
Mag, J.W.3
-
9
-
-
15244353685
-
The biomechanical analysis of a tendon fixation device for flexor tendon repair
-
Su B.W., Proptopsaltis T.S., Koff M.F., Chang K.P., Strauch R.J., Crow S.A., and Rosenwasser M.P. The biomechanical analysis of a tendon fixation device for flexor tendon repair. J Hand Surg Am 30 (2005) 237-245
-
(2005)
J Hand Surg Am
, vol.30
, pp. 237-245
-
-
Su, B.W.1
Proptopsaltis, T.S.2
Koff, M.F.3
Chang, K.P.4
Strauch, R.J.5
Crow, S.A.6
Rosenwasser, M.P.7
-
10
-
-
0029914894
-
A method for combined percutaneous and open surgical repair of Achilles tendon ruptures: a report of three cases
-
Esemenli T., Gundes H., and Mecikoglu M. A method for combined percutaneous and open surgical repair of Achilles tendon ruptures: a report of three cases. Foot Ankle Int 17 (1996) 217-220
-
(1996)
Foot Ankle Int
, vol.17
, pp. 217-220
-
-
Esemenli, T.1
Gundes, H.2
Mecikoglu, M.3
-
11
-
-
0019212127
-
The operative treatment of Achilles tendon injuries
-
Lennox D.W., Wang G.J., and McCue F.C. The operative treatment of Achilles tendon injuries. Clin Orthop 148 (1980) 152-155
-
(1980)
Clin Orthop
, vol.148
, pp. 152-155
-
-
Lennox, D.W.1
Wang, G.J.2
McCue, F.C.3
-
12
-
-
0027942761
-
A biomechanical comparison of techniques of flexor tendon repair
-
Wagner W.F., Carroll C., and Stricland J.W. A biomechanical comparison of techniques of flexor tendon repair. J Hand Surg Am 19 (1994) 979-983
-
(1994)
J Hand Surg Am
, vol.19
, pp. 979-983
-
-
Wagner, W.F.1
Carroll, C.2
Stricland, J.W.3
-
13
-
-
0003139231
-
Prospective trial of conservative and surgical treatment of Achilles tendon rupture
-
Coombs R.R.H. Prospective trial of conservative and surgical treatment of Achilles tendon rupture. J Bone Joint Surg 63B (1981) 288
-
(1981)
J Bone Joint Surg
, vol.63 B
, pp. 288
-
-
Coombs, R.R.H.1
-
14
-
-
0014752424
-
The management of fresh ruptures of the tendo Achillis
-
Gilliess H., and Chalmers J. The management of fresh ruptures of the tendo Achillis. J Bone Joint Surg 52A (1970) 337-343
-
(1970)
J Bone Joint Surg
, vol.52 A
, pp. 337-343
-
-
Gilliess, H.1
Chalmers, J.2
-
15
-
-
0023789648
-
Repair of Achilles tendon ruptures with Dacron vascular graft
-
Liebermen J.R., Lozman J., and Dougerty J. Repair of Achilles tendon ruptures with Dacron vascular graft. Clin Orthop 234 (1988) 204-208
-
(1988)
Clin Orthop
, vol.234
, pp. 204-208
-
-
Liebermen, J.R.1
Lozman, J.2
Dougerty, J.3
-
16
-
-
0019451081
-
Surgical and non-surgical treatment of Achilles tendon rupture. A prospective randomized study
-
Nistor L. Surgical and non-surgical treatment of Achilles tendon rupture. A prospective randomized study. J Bone Joint Surg 63A (1981) 394-399
-
(1981)
J Bone Joint Surg
, vol.63 A
, pp. 394-399
-
-
Nistor, L.1
-
17
-
-
0033988118
-
Achilles tendon rupture repair: biomechanical comparison of the triple bundle technique versus the Krakow locking loop technique
-
Hutton W.C., Beskin J.L., and Lee G.P. Achilles tendon rupture repair: biomechanical comparison of the triple bundle technique versus the Krakow locking loop technique. Foot Ankle Int 21 (2000) 14-17
-
(2000)
Foot Ankle Int
, vol.21
, pp. 14-17
-
-
Hutton, W.C.1
Beskin, J.L.2
Lee, G.P.3
-
18
-
-
0027445990
-
Operative versus nonoperative treatment of Achilles tendon rupture. A prospective randomized study and review of the literature
-
Cetti R., Christensen S.E., Ejsted R., Jensen N.M., and Jorgensen U. Operative versus nonoperative treatment of Achilles tendon rupture. A prospective randomized study and review of the literature. Am J Sports Med 21 (1993) 761-799
-
(1993)
Am J Sports Med
, vol.21
, pp. 761-799
-
-
Cetti, R.1
Christensen, S.E.2
Ejsted, R.3
Jensen, N.M.4
Jorgensen, U.5
-
19
-
-
0038017009
-
Simple end-to-end suture versus augmented repair in acute Achilles tendon ruptures: a retrospective comparison in 98 patients
-
Nyyssonen T., Saarikoski H., Kaukonen J.P., Luthje P., and Hakovirta H. Simple end-to-end suture versus augmented repair in acute Achilles tendon ruptures: a retrospective comparison in 98 patients. Acta Orthop Scand 74 (2003) 206-208
-
(2003)
Acta Orthop Scand
, vol.74
, pp. 206-208
-
-
Nyyssonen, T.1
Saarikoski, H.2
Kaukonen, J.P.3
Luthje, P.4
Hakovirta, H.5
-
20
-
-
0036308271
-
Treatment of acute Achilles tendon ruptures: a systematic overview and meta-analysis
-
Bhandari M., Guyatt G.H., Siddiqui F., Morrow F., Busse J., Leighton R.K., Sprague S., and Schemitsch E.H. Treatment of acute Achilles tendon ruptures: a systematic overview and meta-analysis. Clin Orthop 400 (2002) 190-200
-
(2002)
Clin Orthop
, vol.400
, pp. 190-200
-
-
Bhandari, M.1
Guyatt, G.H.2
Siddiqui, F.3
Morrow, F.4
Busse, J.5
Leighton, R.K.6
Sprague, S.7
Schemitsch, E.H.8
-
21
-
-
0036905218
-
Initial pull-out strength of tendon sutures: an in vitro study in sheep Achilles tendon
-
Yildirim Y., and Esemenli T. Initial pull-out strength of tendon sutures: an in vitro study in sheep Achilles tendon. Foot Ankle Int 23 (2002) 1126-1130
-
(2002)
Foot Ankle Int
, vol.23
, pp. 1126-1130
-
-
Yildirim, Y.1
Esemenli, T.2
-
22
-
-
0033988118
-
Achilles tendon rupture repair: biomechanical comparison of the triple bundle technique versus the Krakow locking loop technique
-
Jaakkola J.I., Hutton W.C., Beskin J.L., and Lee G.P. Achilles tendon rupture repair: biomechanical comparison of the triple bundle technique versus the Krakow locking loop technique. Foot Ankle Int 21 (2000) 14-17
-
(2000)
Foot Ankle Int
, vol.21
, pp. 14-17
-
-
Jaakkola, J.I.1
Hutton, W.C.2
Beskin, J.L.3
Lee, G.P.4
-
23
-
-
0018424934
-
The locking loop tendon suture
-
Penington G.D. The locking loop tendon suture. Plast Reconstr Surg 63 (1979) 648-652
-
(1979)
Plast Reconstr Surg
, vol.63
, pp. 648-652
-
-
Penington, G.D.1
-
24
-
-
0031112839
-
The strength of Achilles tendon repair: in an in vitro study of the biomechanical behaviour in human cadaver tendons
-
Esemenli T. The strength of Achilles tendon repair: in an in vitro study of the biomechanical behaviour in human cadaver tendons. Foot Ankle Int 18 (1997) 250
-
(1997)
Foot Ankle Int
, vol.18
, pp. 250
-
-
Esemenli, T.1
|