메뉴 건너뛰기




Volumn 60, Issue 6, 2005, Pages 302-306

A case of Legionnaires' disease caused by aspiration of ice water

Author keywords

Aspiration; Disease causing dose; Ice cubes; Ice making machine; Legionnaires' disease

Indexed keywords

ICE;

EID: 34247155725     PISSN: 19338244     EISSN: None     Source Type: Journal    
DOI: 10.3200/AEOH.60.6.302-306     Document Type: Article
Times cited : (24)

References (18)
  • 1
    • 0019916003 scopus 로고
    • Nosocomial Legionnaires' disease caused by aerosolized tap water from respiratory devices
    • Arnow PM, Chou T, Weil D, Shapiro EN, Kretzschmar C. Nosocomial Legionnaires' disease caused by aerosolized tap water from respiratory devices. J Infect Dis. 1982;146:460-467.
    • (1982) J Infect Dis , vol.146 , pp. 460-467
    • Arnow, P.M.1    Chou, T.2    Weil, D.3    Shapiro, E.N.4    Kretzschmar, C.5
  • 2
    • 0023276969 scopus 로고
    • Nosocomial legionellosis associated with use of oxygen bubble humidifiers and underwater chest drains
    • Moiraghi A, Castellani Pastoris M, Barral C, et al. Nosocomial legionellosis associated with use of oxygen bubble humidifiers and underwater chest drains. J Hosp Infect. 1987;10:47-50.
    • (1987) J Hosp Infect , vol.10 , pp. 47-50
    • Moiraghi, A.1    Castellani Pastoris, M.2    Barral, C.3
  • 3
    • 0024516339 scopus 로고
    • Legionella pneumophila in a hospital in Torino, Italy, a retrospective one-year study
    • Moiraghi Ruggenini A, Castellani Pastoris M, Dennis PJ, et al. Legionella pneumophila in a hospital in Torino, Italy, a retrospective one-year study. Epidemiol Infect. 1989;102:21-29.
    • (1989) Epidemiol Infect , vol.102 , pp. 21-29
    • Moiraghi Ruggenini, A.1    Castellani Pastoris, M.2    Dennis, P.J.3
  • 5
    • 0026463026 scopus 로고
    • Transmission of Legionella by respiratory equipment and aerosol generating devices
    • Woo AH, Goetz A, Yu VL. Transmission of Legionella by respiratory equipment and aerosol generating devices. Chest. 1992;102: 1586-1590.
    • (1992) Chest , vol.102 , pp. 1586-1590
    • Woo, A.H.1    Goetz, A.2    Yu, V.L.3
  • 6
    • 0018898448 scopus 로고
    • An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower
    • Dondero TJ Jr, Rendtorff RC, Mallison GF, et al. An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower. N Engl J Med. 1980;302:365-370.
    • (1980) N Engl J Med , vol.302 , pp. 365-370
    • Dondero Jr, T.J.1    Rendtorff, R.C.2    Mallison, G.F.3
  • 8
    • 0021875323 scopus 로고
    • Nosocomial legionellosis in surgical patients with head-and-neck cancer: Implications for epidemiological reservoir and mode of transmission
    • Johnson JT, Yu VL, Best MG, et al. Nosocomial legionellosis in surgical patients with head-and-neck cancer: implications for epidemiological reservoir and mode of transmission. Lancet. 1985;2:298-300.
    • (1985) Lancet , vol.2 , pp. 298-300
    • Johnson, J.T.1    Yu, V.L.2    Best, M.G.3
  • 9
    • 0033255498 scopus 로고    scopus 로고
    • Hospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial Legionnaires' disease: A cohort study of 15 hospitals
    • Kool JL, Bergmire-Sweat D, Butler JC, et al. Hospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial Legionnaires' disease: a cohort study of 15 hospitals. Infect Control Hosp Epidemiol. 1999;20:798-805.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 798-805
    • Kool, J.L.1    Bergmire-Sweat, D.2    Butler, J.C.3
  • 10
    • 0021946398 scopus 로고
    • Isolation of Legionella pneumophila from the cold water of hospital ice machines: Implications for origin and transmission of the organism
    • Stout JE, Yu VL, Muraca P. Isolation of Legionella pneumophila from the cold water of hospital ice machines: implications for origin and transmission of the organism. Infect Control. 1985;6:141-146.
    • (1985) Infect Control , vol.6 , pp. 141-146
    • Stout, J.E.1    Yu, V.L.2    Muraca, P.3
  • 11
    • 0028607638 scopus 로고
    • A hospital study of ice-making machines: Their bacteriology, design, usage and upkeep
    • Burnett IA, Weeks GR, Harris DM. A hospital study of ice-making machines: their bacteriology, design, usage and upkeep. J Hosp Infect. 1994;28:305-313.
    • (1994) J Hosp Infect , vol.28 , pp. 305-313
    • Burnett, I.A.1    Weeks, G.R.2    Harris, D.M.3
  • 12
    • 0028964063 scopus 로고
    • Nosocomial legionellosis in three heart-lung transplant patients: Case reports and environmental observations
    • Bangsborg JM, Uldum S, Jensen JS, Bruun BG. Nosocomial legionellosis in three heart-lung transplant patients: case reports and environmental observations. Eur J Clin Microbiol Infect Dis. 1995;14: 99-104.
    • (1995) Eur J Clin Microbiol Infect Dis , vol.14 , pp. 99-104
    • Bangsborg, J.M.1    Uldum, S.2    Jensen, J.S.3    Bruun, B.G.4
  • 14
    • 84898709465 scopus 로고    scopus 로고
    • Standard European Working Group on Legionella Infections Amplified Fragment Length Polymorphism Protocol version 1.2. Available at:, Accessed February 2005
    • Standard European Working Group on Legionella Infections Amplified Fragment Length Polymorphism Protocol version 1.2. Available at: http://www.EWGLI.org. Accessed February 2005.
  • 16
    • 0027154032 scopus 로고
    • Legionnaires' disease: The infective dose paradox
    • O'Brien SJ, Bhopal RS. Legionnaires' disease: the infective dose paradox. Lancet. 1993; 342:5-6.
    • (1993) Lancet , vol.342 , pp. 5-6
    • O'Brien, S.J.1    Bhopal, R.S.2
  • 17
    • 0036156233 scopus 로고    scopus 로고
    • A large outbreak of Legionnaires' disease at a flower show, The Netherlands, 1999
    • Den Boer JW, Yzerman EP, Schellekens J, et al. A large outbreak of Legionnaires' disease at a flower show, The Netherlands, 1999. Emerg Inf Dis. 2002;8:37-43.
    • (2002) Emerg Inf Dis , vol.8 , pp. 37-43
    • Den Boer, J.W.1    Yzerman, E.P.2    Schellekens, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.