메뉴 건너뛰기




Volumn 6, Issue 2, 2007, Pages 257-259

Hybrid antegrade repair of the arch and descending thoracic aorta with a new integrated stent-Dacron graft in acute type a aortic dissection: A look into the future with new devices

Author keywords

Acute type A aortic dissection; Antegrade deployment; False lumen; Stent graft

Indexed keywords

ADULT; AORTA DISSECTION; AORTA VALVE REGURGITATION; ARTICLE; CASE REPORT; HUMAN; IMAGING SYSTEM; MALE; PRIORITY JOURNAL; STENT; SURGICAL TECHNIQUE; TREATMENT OUTCOME;

EID: 34247131828     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2006.141010     Document Type: Article
Times cited : (20)

References (10)
  • 1
    • 0020914076 scopus 로고
    • Extensive aortic replacement using 'elephant trunk' prosthesis
    • Borst HG, Walterbusch G, Schaps D. Extensive aortic replacement using 'elephant trunk' prosthesis. Thorac Cardiovasc Surg 1983;31:37-40.
    • (1983) Thorac Cardiovasc Surg , vol.31 , pp. 37-40
    • Borst, H.G.1    Walterbusch, G.2    Schaps, D.3
  • 3
    • 33746681888 scopus 로고    scopus 로고
    • New open-stent graft delivery system: 'the CLATE flexible metal graft holder'
    • Doi:10.1510yicvts.2006.129882
    • Kubota H, Endo H, Sudo K. New open-stent graft delivery system: 'the CLATE flexible metal graft holder'. Interact Cardiovasc Thorac Surg Doi:10.1510yicvts.2006.129882.
    • Interact Cardiovasc Thorac Surg
    • Kubota, H.1    Endo, H.2    Sudo, K.3
  • 4
    • 0027946422 scopus 로고
    • Total arch graft replacement in patients with acute type A aortic dissection
    • Kazui T, Kimura N, Yamada O, Komatsu S. Total arch graft replacement in patients with acute type A aortic dissection. Ann Thorac Surg 1994;58:1462-1468.
    • (1994) Ann Thorac Surg , vol.58 , pp. 1462-1468
    • Kazui, T.1    Kimura, N.2    Yamada, O.3    Komatsu, S.4
  • 5
    • 33645388881 scopus 로고    scopus 로고
    • Stenting the descending thoracic aorta during repair of Type A dissection: Technology looking for an application?
    • Dobrilovic N, Elefteriades J. Stenting the descending thoracic aorta during repair of Type A dissection: technology looking for an application? J Thorac Cardiovasc Surg 2006;131:777-778.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 777-778
    • Dobrilovic, N.1    Elefteriades, J.2
  • 6
    • 28744433426 scopus 로고    scopus 로고
    • Development of an integrated stent graft-dacron prosthesis for intended one-stage repair in complex thoracic aortic disease
    • Jakob H, Tsagakis K, Leyh R, Buck T, Herold U. Development of an integrated stent graft-dacron prosthesis for intended one-stage repair in complex thoracic aortic disease. Herz 2005;30:766-768.
    • (2005) Herz , vol.30 , pp. 766-768
    • Jakob, H.1    Tsagakis, K.2    Leyh, R.3    Buck, T.4    Herold, U.5
  • 7
    • 22544437586 scopus 로고    scopus 로고
    • The frozen elephant trunk technique for the treatment of extensive thoracic aortic aneurysms: Operative results and follow-up
    • Karck M, Chavan A, Khaladj N, Friedrich H, Hagl C, Haverich A. The frozen elephant trunk technique for the treatment of extensive thoracic aortic aneurysms: operative results and follow-up. Eur J Cardiothorac Surg 2005;28:286-190.
    • (2005) Eur J Cardiothorac Surg , vol.28 , pp. 286-190
    • Karck, M.1    Chavan, A.2    Khaladj, N.3    Friedrich, H.4    Hagl, C.5    Haverich, A.6
  • 8
    • 33645390163 scopus 로고    scopus 로고
    • Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection
    • Uchida N, Ishihara H, Shibamura H, Kyo Y, Ozawa M. Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection. J Thorac Cardiovasc Surg 2006;131:862-867.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 862-867
    • Uchida, N.1    Ishihara, H.2    Shibamura, H.3    Kyo, Y.4    Ozawa, M.5
  • 9
    • 0036740773 scopus 로고    scopus 로고
    • The results of total arch graft implantation with open stent-graft placement for type A aortic dissection
    • Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K. The results of total arch graft implantation with open stent-graft placement for type A aortic dissection. J Thorac Cardiovasc Surg 2002;124:531-540.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 531-540
    • Kato, M.1    Kuratani, T.2    Kaneko, M.3    Kyo, S.4    Ohnishi, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.