메뉴 건너뛰기




Volumn 35, Issue 4, 2007, Pages 1145-1152

Inspiratory resistance maintains arterial pressure during central hypovolemia: Implications for treatment of patients with severe hemorrhage

Author keywords

Cardiovascular collapse; Hemorrhagic shock; Impedance threshold device; Intrathoracic pressure; Lower body negative pressure

Indexed keywords

ADULT; ARTICLE; BREATHING; DEVICE; DIASTOLIC BLOOD PRESSURE; FEMALE; HEMODYNAMICS; HEMORRHAGIC SHOCK; HUMAN; HYPOTENSION; HYPOVOLEMIA; IMPEDANCE; INSPIRATORY CAPACITY; LABORATORY; LOWER BODY NEGATIVE PRESSURE; MALE; MEAN ARTERIAL PRESSURE; PHYSIOLOGY; PRIORITY JOURNAL; PROSPECTIVE STUDY; SYMPTOM; SYSTOLIC BLOOD PRESSURE; VOLUNTEER;

EID: 34247129202     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000259464.83188.2C     Document Type: Article
Times cited : (55)

References (37)
  • 1
    • 0028909841 scopus 로고
    • Epidemiology of trauma deaths: A reassessment
    • Sauaia A, Moore FA, Moore EE, et al: Epidemiology of trauma deaths: A reassessment. J Trauma 1995; 38:185-193
    • (1995) J Trauma , vol.38 , pp. 185-193
    • Sauaia, A.1    Moore, F.A.2    Moore, E.E.3
  • 2
    • 0021378321 scopus 로고
    • The causes of death in conventional land warfare: Implications for combat casualty care research
    • Bellamy RF: The causes of death in conventional land warfare: Implications for combat casualty care research. Mil Med 1984; 149:55-62
    • (1984) Mil Med , vol.149 , pp. 55-62
    • Bellamy, R.F.1
  • 3
    • 0029933274 scopus 로고    scopus 로고
    • Analysis of wounds incurred by U.S. Army Seventh Corps personnel treated in Corps hospitals during Operation Desert Storm, February 20 to March 10, 1991
    • Carey ME: Analysis of wounds incurred by U.S. Army Seventh Corps personnel treated in Corps hospitals during Operation Desert Storm, February 20 to March 10, 1991. J Trauma 1996; 40:S165-S169
    • (1996) J Trauma , vol.40
    • Carey, M.E.1
  • 4
    • 0027383788 scopus 로고
    • Prehospital traumatic cardiac arrest: The cost of futility
    • Rosemurgy AS, Norris PA, Olson SM, et al: Prehospital traumatic cardiac arrest: The cost of futility. J Trauma 1993; 35:468-473
    • (1993) J Trauma , vol.35 , pp. 468-473
    • Rosemurgy, A.S.1    Norris, P.A.2    Olson, S.M.3
  • 5
    • 0020577235 scopus 로고
    • Outcomes of trauma patients with no vital signs on hospital admission
    • Shimazu S, Shatney CH: Outcomes of trauma patients with no vital signs on hospital admission. J Trauma 1983; 23:213-216
    • (1983) J Trauma , vol.23 , pp. 213-216
    • Shimazu, S.1    Shatney, C.H.2
  • 8
    • 0033943023 scopus 로고    scopus 로고
    • Pre-hospital hypotension as a valid indicator of trauma team activation
    • Franklin GA, Boaz PW, Spain DA, et al: Pre-hospital hypotension as a valid indicator of trauma team activation. J Trauma 2000; 48:1034-1037
    • (2000) J Trauma , vol.48 , pp. 1034-1037
    • Franklin, G.A.1    Boaz, P.W.2    Spain, D.A.3
  • 9
    • 15944425783 scopus 로고    scopus 로고
    • Pre-hospital physiologic data and lifesaving interventions in trauma patients
    • Holcomb JB, Niles SE, Miller CC, et al: Pre-hospital physiologic data and lifesaving interventions in trauma patients. Mil Med 2005; 170:7-13
    • (2005) Mil Med , vol.170 , pp. 7-13
    • Holcomb, J.B.1    Niles, S.E.2    Miller, C.C.3
  • 10
    • 0014117884 scopus 로고
    • Respiratory regulation of splanchnic and systemic venous return
    • Moreno AH, Burchell AR, Van der Woude R, et al: Respiratory regulation of splanchnic and systemic venous return. Am J Physiol 1967; 213:455-465
    • (1967) Am J Physiol , vol.213 , pp. 455-465
    • Moreno, A.H.1    Burchell, A.R.2    Van der Woude, R.3
  • 11
    • 16244389376 scopus 로고    scopus 로고
    • Inspiratory resistance as a potential treatment for orthostatic intolerance and hemorrhagic shock
    • Convertino VA, Cooke WH, Lurie KG: Inspiratory resistance as a potential treatment for orthostatic intolerance and hemorrhagic shock. Aviat Space Environ Med 2005; 76:319-325
    • (2005) Aviat Space Environ Med , vol.76 , pp. 319-325
    • Convertino, V.A.1    Cooke, W.H.2    Lurie, K.G.3
  • 12
    • 0034078714 scopus 로고    scopus 로고
    • Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: A progress report
    • Lurie K, Voelckel W, Plaisance P, et al: Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: A progress report. Resuscitation 2000; 44:219-230
    • (2000) Resuscitation , vol.44 , pp. 219-230
    • Lurie, K.1    Voelckel, W.2    Plaisance, P.3
  • 13
    • 0033710526 scopus 로고    scopus 로고
    • Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    • Lurie K, Zielinski T, McKnite S, et al: Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Crit Care Med 2000; 28:N207-N209
    • (2000) Crit Care Med , vol.28
    • Lurie, K.1    Zielinski, T.2    McKnite, S.3
  • 14
    • 0034007187 scopus 로고    scopus 로고
    • Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: A randomized evaluation in patients in cardiac arrest
    • Plaisance P, Lurie KG, Payen D: Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: A randomized evaluation in patients in cardiac arrest. Circulation 2000; 101:989-994
    • (2000) Circulation , vol.101 , pp. 989-994
    • Plaisance, P.1    Lurie, K.G.2    Payen, D.3
  • 15
    • 7244237931 scopus 로고    scopus 로고
    • Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers
    • Convertino VA, Ratliff DA, Ryan KL, et al: Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers. Crit Care Med 2004; 32:S381-S386
    • (2004) Crit Care Med , vol.32
    • Convertino, V.A.1    Ratliff, D.A.2    Ryan, K.L.3
  • 16
    • 3142749613 scopus 로고    scopus 로고
    • Treatment of hypotension in pigs with an inspiratory impedance threshold device: A feasibility study
    • Lurie KG, Zielinski TM, McKnite SH, et al: Treatment of hypotension in pigs with an inspiratory impedance threshold device: A feasibility study. Crit Care Med 2004; 32:1555-1562
    • (2004) Crit Care Med , vol.32 , pp. 1555-1562
    • Lurie, K.G.1    Zielinski, T.M.2    McKnite, S.H.3
  • 17
    • 7244227710 scopus 로고    scopus 로고
    • Spontaneous breathing through an inspiratory impedance threshold device augments cardiac index and stroke volume index in a pediatric porcine model of hemorrhagic hypovolemia
    • Marino BS, Yannopoulos D, Sigurdsson G, et al: Spontaneous breathing through an inspiratory impedance threshold device augments cardiac index and stroke volume index in a pediatric porcine model of hemorrhagic hypovolemia. Crit Care Med 2004; 32:S398-S405
    • (2004) Crit Care Med , vol.32
    • Marino, B.S.1    Yannopoulos, D.2    Sigurdsson, G.3
  • 18
    • 33344477450 scopus 로고    scopus 로고
    • Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigs
    • Sigurdsson G, Yannopoulos D, McKnite SH, et al: Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigs. Resuscitation 2006; 68:399-404
    • (2006) Resuscitation , vol.68 , pp. 399-404
    • Sigurdsson, G.1    Yannopoulos, D.2    McKnite, S.H.3
  • 19
    • 22144440471 scopus 로고    scopus 로고
    • Effects of inspiratory impedance on hemodynamic responses to a squat-stand test in human volunteers: Implications for treatment of orthostatic hypotension
    • Convertino VA, Ratliff DA, Crissey J, et al: Effects of inspiratory impedance on hemodynamic responses to a squat-stand test in human volunteers: Implications for treatment of orthostatic hypotension. Eur J Appl Physiol 2005; 94:392-399
    • (2005) Eur J Appl Physiol , vol.94 , pp. 392-399
    • Convertino, V.A.1    Ratliff, D.A.2    Crissey, J.3
  • 20
    • 33751072436 scopus 로고    scopus 로고
    • Restoration of central blood volume: Application of a simple concept and simple device to counteract cardiovascular instability in syncope and hemorrhage
    • Convertino VA, Cooke WH, Lurie KG: Restoration of central blood volume: Application of a simple concept and simple device to counteract cardiovascular instability in syncope and hemorrhage. J Gravit Physiol 2005; 12:P55-P60
    • (2005) J Gravit Physiol , vol.12
    • Convertino, V.A.1    Cooke, W.H.2    Lurie, K.G.3
  • 21
    • 1642293151 scopus 로고    scopus 로고
    • Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans
    • Cooke WH, Ryan KL, Convertino VA: Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans. J Appl Physiol 2004; 96:1249-1261
    • (2004) J Appl Physiol , vol.96 , pp. 1249-1261
    • Cooke, W.H.1    Ryan, K.L.2    Convertino, V.A.3
  • 22
    • 0034858508 scopus 로고    scopus 로고
    • Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest
    • Lurie KG, Voelckel WG, Zielinski T, et al: Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg 2001; 93:649-655
    • (2001) Anesth Analg , vol.93 , pp. 649-655
    • Lurie, K.G.1    Voelckel, W.G.2    Zielinski, T.3
  • 23
    • 0028959943 scopus 로고
    • Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve
    • Lurie KG, Coffeen P, Shultz J, et al: Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve. Circulation 1995; 91:1629-1632
    • (1995) Circulation , vol.91 , pp. 1629-1632
    • Lurie, K.G.1    Coffeen, P.2    Shultz, J.3
  • 24
    • 4444298733 scopus 로고    scopus 로고
    • Effects of inspiratory impedance on the carotid-cardiac baroreflex response in humans
    • Convertino VA, Ratliff DA, Ryan KL, et al: Effects of inspiratory impedance on the carotid-cardiac baroreflex response in humans. Clin Auton Res 2004; 14:240-248
    • (2004) Clin Auton Res , vol.14 , pp. 240-248
    • Convertino, V.A.1    Ratliff, D.A.2    Ryan, K.L.3
  • 25
    • 85047680055 scopus 로고
    • Continuous non-invasive blood pressure monitoring: Reliability of Finapres device during the Valsalva manoeuvre
    • Imholz BP, van Montfrans GA, Settels JJ, et al: Continuous non-invasive blood pressure monitoring: Reliability of Finapres device during the Valsalva manoeuvre. Cardiovasc Res 1988; 22:390-397
    • (1988) Cardiovasc Res , vol.22 , pp. 390-397
    • Imholz, B.P.1    van Montfrans, G.A.2    Settels, J.J.3
  • 26
    • 85047676115 scopus 로고
    • Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • Imholz BP, Settels JJ, van der Meiracker AH, et al: Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc Res 1990; 24:214-221
    • (1990) Cardiovasc Res , vol.24 , pp. 214-221
    • Imholz, B.P.1    Settels, J.J.2    van der Meiracker, A.H.3
  • 27
    • 0024344783 scopus 로고
    • Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing
    • Parati G, Casadei R, Groppelli A, et al: Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension 1989; 13:647-655
    • (1989) Hypertension , vol.13 , pp. 647-655
    • Parati, G.1    Casadei, R.2    Groppelli, A.3
  • 28
    • 33745491620 scopus 로고
    • Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
    • Wesseling KH, Settels JJ, van der Hoeven GM, et al: Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. Cardiovasc Res 1985; 19:139-145
    • (1985) Cardiovasc Res , vol.19 , pp. 139-145
    • Wesseling, K.H.1    Settels, J.J.2    van der Hoeven, G.M.3
  • 29
    • 0024581430 scopus 로고
    • Adaptation to repeated presyncopal lower body negative pressure exposures
    • Lightfoot JT, Febles S, Fortney SM: Adaptation to repeated presyncopal lower body negative pressure exposures. Aviat Space Environ Med 1989; 60:17-22
    • (1989) Aviat Space Environ Med , vol.60 , pp. 17-22
    • Lightfoot, J.T.1    Febles, S.2    Fortney, S.M.3
  • 30
    • 0025964726 scopus 로고
    • Repeatability and protocol comparability of presyncopal symptom limited lower body negative pressure exposures
    • Lightfoot JT, Hilton F Jr, Fortney SM: Repeatability and protocol comparability of presyncopal symptom limited lower body negative pressure exposures. Aviat Space Environ Med 1991; 62:19-25
    • (1991) Aviat Space Environ Med , vol.62 , pp. 19-25
    • Lightfoot, J.T.1    Hilton Jr, F.2    Fortney, S.M.3
  • 31
    • 0022639823 scopus 로고
    • Cardiovascular dynamics associated with tolerance to lower body negative pressure
    • Sather TM, Goldwater DJ, Montgomery LD, et al: Cardiovascular dynamics associated with tolerance to lower body negative pressure. Aviat Space Environ Med 1986; 57:413-419
    • (1986) Aviat Space Environ Med , vol.57 , pp. 413-419
    • Sather, T.M.1    Goldwater, D.J.2    Montgomery, L.D.3
  • 32
    • 0035017641 scopus 로고    scopus 로고
    • The reproducibility of tolerance to lower-body negative pressure and its quantification
    • Howden R, Tranfield PA, Lightfoot JT, et al: The reproducibility of tolerance to lower-body negative pressure and its quantification. Eur J Appl Physiol 2001; 84:462-468
    • (2001) Eur J Appl Physiol , vol.84 , pp. 462-468
    • Howden, R.1    Tranfield, P.A.2    Lightfoot, J.T.3
  • 33
    • 0038339548 scopus 로고    scopus 로고
    • Blood pressure at which rebleeding occurs after resuscitation in swine with aortic injury
    • Sondeen JL, Coppes VG, Holcomb JB: Blood pressure at which rebleeding occurs after resuscitation in swine with aortic injury. J Trauma 2003; 54:S110-S117
    • (2003) J Trauma , vol.54
    • Sondeen, J.L.1    Coppes, V.G.2    Holcomb, J.B.3
  • 34
    • 33646494473 scopus 로고    scopus 로고
    • Inspiratory impedance effects on hemodynamic responses to orthostasis in normal subjects
    • Convertino VA, Ratliff DA, Eisenhower KC, et al: Inspiratory impedance effects on hemodynamic responses to orthostasis in normal subjects. Aviat Space Environ Med 2006; 77:486-493
    • (2006) Aviat Space Environ Med , vol.77 , pp. 486-493
    • Convertino, V.A.1    Ratliff, D.A.2    Eisenhower, K.C.3
  • 35
    • 33947519698 scopus 로고    scopus 로고
    • Imposed power of breathing associated with use of an impedance threshold device
    • Idris AH, Convertino VA, Ratliff DA, et al: Imposed power of breathing associated with use of an impedance threshold device. Respiratory Care 2007; 52:177-183
    • (2007) Respiratory Care , vol.52 , pp. 177-183
    • Idris, A.H.1    Convertino, V.A.2    Ratliff, D.A.3
  • 36
    • 33747887355 scopus 로고    scopus 로고
    • Intrathoracic pressure regulation improves vital organ perfusion pressures in normovolemic and hypovolemic pigs
    • Yannopoulos D, Metzger A, McKnite S, et al: Intrathoracic pressure regulation improves vital organ perfusion pressures in normovolemic and hypovolemic pigs. Resuscitation 2006; 70:445-453
    • (2006) Resuscitation , vol.70 , pp. 445-453
    • Yannopoulos, D.1    Metzger, A.2    McKnite, S.3
  • 37
    • 23844534502 scopus 로고    scopus 로고
    • Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest
    • Yannopoulos D, Nadkarni VM, McKnite SH, et al: Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest. Circulation 2005; 112:803-811
    • (2005) Circulation , vol.112 , pp. 803-811
    • Yannopoulos, D.1    Nadkarni, V.M.2    McKnite, S.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.