메뉴 건너뛰기




Volumn 131, Issue 4 SUPPL., 2007, Pages

Convenient removal of orthodontic mini-implants

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE SCREW; DEVICE REMOVAL; HUMAN; INSTRUMENTATION; METHODOLOGY; ORTHODONTICS; TOOTH IMPLANTATION;

EID: 34247125566     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2005.04.040     Document Type: Article
Times cited : (1)

References (9)
  • 1
    • 16544393095 scopus 로고    scopus 로고
    • The C-orthodontic micro-implant
    • Chung K., Kim S., and Kook Y. The C-orthodontic micro-implant. J Clin Orthod 38 (2004) 478-486
    • (2004) J Clin Orthod , vol.38 , pp. 478-486
    • Chung, K.1    Kim, S.2    Kook, Y.3
  • 2
    • 0036580590 scopus 로고    scopus 로고
    • Clinical application of micro-implant anchorage
    • Bae S., Park H., Kyung H., Kwon O., and Sung J. Clinical application of micro-implant anchorage. J Clin Orthod 36 (2002) 298-302
    • (2002) J Clin Orthod , vol.36 , pp. 298-302
    • Bae, S.1    Park, H.2    Kyung, H.3    Kwon, O.4    Sung, J.5
  • 3
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion
    • Park H., Bae S., Kyung H., and Sung J. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 35 (2001) 417-422
    • (2001) J Clin Orthod , vol.35 , pp. 417-422
    • Park, H.1    Bae, S.2    Kyung, H.3    Sung, J.4
  • 4
    • 13244284696 scopus 로고    scopus 로고
    • Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment
    • Hong R., Heo J., and Ha Y. Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment. Angle Orthod 75 (2005) 129-141
    • (2005) Angle Orthod , vol.75 , pp. 129-141
    • Hong, R.1    Heo, J.2    Ha, Y.3
  • 5
    • 5444263274 scopus 로고    scopus 로고
    • The lingual plain-wire system with micro-implant anchorage
    • Kyung H., Park H., Bae S., Sung J., and Kim I. The lingual plain-wire system with micro-implant anchorage. J Clin Orthod 38 (2004) 388-395
    • (2004) J Clin Orthod , vol.38 , pp. 388-395
    • Kyung, H.1    Park, H.2    Bae, S.3    Sung, J.4    Kim, I.5
  • 6
    • 1642303902 scopus 로고    scopus 로고
    • Uprighting second molars with micro-implant anchorage
    • Park H., Kwon O., and Sung J. Uprighting second molars with micro-implant anchorage. J Clin Orthod 38 (2004) 100-103
    • (2004) J Clin Orthod , vol.38 , pp. 100-103
    • Park, H.1    Kwon, O.2    Sung, J.3
  • 7
    • 0035344075 scopus 로고    scopus 로고
    • A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog
    • Ohmae M., Saito S., Morohashi T., Seki K., Qu H., Kanomi R., et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop 119 (2001) 489-497
    • (2001) Am J Orthod Dentofacial Orthop , vol.119 , pp. 489-497
    • Ohmae, M.1    Saito, S.2    Morohashi, T.3    Seki, K.4    Qu, H.5    Kanomi, R.6
  • 8
    • 0036980421 scopus 로고    scopus 로고
    • A stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants
    • Kitai N., Yasuda Y., and Takada K. A stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants. Int J Adult Orthod Orthognath Surg 17 (2002) 264-266
    • (2002) Int J Adult Orthod Orthognath Surg , vol.17 , pp. 264-266
    • Kitai, N.1    Yasuda, Y.2    Takada, K.3
  • 9
    • 0036719664 scopus 로고    scopus 로고
    • Template fabrication for a midpalatal orthodontic implant: technical note
    • Martin W., Heffernan M., and Ruskin J. Template fabrication for a midpalatal orthodontic implant: technical note. Int J Oral Maxillofac Implants 17 (2002) 720-722
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 720-722
    • Martin, W.1    Heffernan, M.2    Ruskin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.