메뉴 건너뛰기




Volumn 53, Issue 2, 2007, Pages 140-146

Minimal sensor count approach to fuzzy logic rotary blood pump flow control

Author keywords

[No Author keywords available]

Indexed keywords

APPROXIMATION THEORY; FLOW CONTROL; FLOW MEASUREMENT; FUZZY CONTROL; FUZZY LOGIC; NONLINEAR CONTROL SYSTEMS;

EID: 34247115601     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mat.0000250786.56697.f2     Document Type: Article
Times cited : (19)

References (8)
  • 1
    • 0348231944 scopus 로고    scopus 로고
    • A fuzzy system cardiopulmonary bypass rotary blood pump controller
    • Casas F, Orozco A, Smith WA, et al: A fuzzy system cardiopulmonary bypass rotary blood pump controller. Expert Systems Applications 24: 357-361, 2004.
    • (2004) Expert Systems Applications , vol.24 , pp. 357-361
    • Casas, F.1    Orozco, A.2    Smith, W.A.3
  • 3
    • 0037880523 scopus 로고    scopus 로고
    • Operating point control system for a continuous flow artificial heart: In vitro study
    • Kosaka R, Yanagi K: Operating point control system for a continuous flow artificial heart: in vitro study. ASAIO J 49: 259-264, 2003.
    • (2003) ASAIO J , vol.49 , pp. 259-264
    • Kosaka, R.1    Yanagi, K.2
  • 4
    • 0032720493 scopus 로고    scopus 로고
    • System analysis of the flow/pressure response of rotodynamic blood pumps
    • Smith WA, Goodin M, Fu M, et al: System analysis of the flow/pressure response of rotodynamic blood pumps. Artif Organs 23: 947-955, 1999.
    • (1999) Artif Organs , vol.23 , pp. 947-955
    • Smith, W.A.1    Goodin, M.2    Fu, M.3
  • 5
    • 0034098785 scopus 로고    scopus 로고
    • Computer simulation of sensorless fuzzy control of a rotary blood pump to assure normal physiology
    • Fu M, Xu L: Computer simulation of sensorless fuzzy control of a rotary blood pump to assure normal physiology. ASAIO J 46: 273-278, 2000.
    • (2000) ASAIO J , vol.46 , pp. 273-278
    • Fu, M.1    Xu, L.2
  • 6
    • 33644875003 scopus 로고    scopus 로고
    • Performance and reliability of the CPB/ECMO initiative forward lines casualty management system
    • Casas F, Reeves A, Dudzinski D, et al: Performance and reliability of the CPB/ECMO initiative forward lines casualty management system. ASAIO J 51: 681-685, 2005.
    • (2005) ASAIO J , vol.51 , pp. 681-685
    • Casas, F.1    Reeves, A.2    Dudzinski, D.3
  • 7
    • 27744511875 scopus 로고    scopus 로고
    • A portable CPB/ECMO system for the induction and reversal of profound hypothermia: Feasibility study in a swine model of lethal injuries
    • Casas F, Alam H, Reeves A, et al: A portable CPB/ECMO system for the induction and reversal of profound hypothermia: feasibility study in a swine model of lethal injuries. Artif Organs 29: 557-563, 2005.
    • (2005) Artif Organs , vol.29 , pp. 557-563
    • Casas, F.1    Alam, H.2    Reeves, A.3
  • 8
    • 33845751482 scopus 로고    scopus 로고
    • Development and testing of portable pump for the induction of profound hypothermia in a swine model of lethal vascular injuries
    • Hasan BA, Casas F, Chen Z, et al: Development and testing of portable pump for the induction of profound hypothermia in a swine model of lethal vascular injuries. J Trauma 61:1321-1329, 2006.
    • (2006) J Trauma , vol.61 , pp. 1321-1329
    • Hasan, B.A.1    Casas, F.2    Chen, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.