메뉴 건너뛰기




Volumn 31, Issue 4, 2007, Pages 28-32

A new method for hybrid non-linear state estimation with PMU

Author keywords

Hybrid measurement; Measurement transforming; Phasor measurement unit; Power systems; State estimation

Indexed keywords

ELECTRIC CURRENT MEASUREMENT; ELECTRIC POWER SYSTEMS; MATLAB; MEASUREMENT ERRORS; UNITS OF MEASUREMENT;

EID: 34147224210     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (39)

References (17)
  • 1
    • 0028480351 scopus 로고
    • Synchronized phasor measurements of a power system event
    • BURNETT R O, BUTTS M M, CEASE T W, et al. Synchronized phasor measurements of a power system event. IEEE Trans on Power Systems, 1994, 9(3): 1643-1650.
    • (1994) IEEE Trans on Power Systems , vol.9 , Issue.3 , pp. 1643-1650
    • Burnett, R.O.1    Butts, M.M.2    Cease, T.W.3
  • 2
    • 34147214750 scopus 로고    scopus 로고
    • Phasor measurement and its application in power systems
    • LU Zhigang, HAO Yushan, KANG Qingping, et al. Phasor measurement and its application in power systems. Automation of Electric Power Systems, 2004, 28(6): 5-9.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.6 , pp. 5-9
    • Lu, Z.1    Hao, Y.2    Kang, Q.3
  • 3
    • 33846806920 scopus 로고    scopus 로고
    • An overview of state estimation based on wide-area measurement system
    • DING Junce, CAI Zexiang, WANG Keying. An overview of state estimation based on wide-area measurement system. Automation of Electric Power Systems, 2006, 30(7): 98-103.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.7 , pp. 98-103
    • Ding, J.1    Cai, Z.2    Wang, K.3
  • 5
    • 0027589817 scopus 로고
    • Power system observability with minimal phasor measurement placement
    • BALDWIN T L, BOISON M L, BOISEN M B, et al. Power system observability with minimal phasor measurement placement. IEEE Trans on Power Systems, 1993, 8(2): 707- 715.
    • (1993) IEEE Trans on Power Systems , vol.8 , Issue.2 , pp. 707-715
    • Baldwin, T.L.1    Boison, M.L.2    Boisen, M.B.3
  • 6
    • 0033640353 scopus 로고    scopus 로고
    • State estimation of voltage phasors based on parts of voltage and current phasors measurements
    • LU Zhigang, XU Shifan, SHI Zenghong, et al. State estimation of voltage phasors based on parts of voltage and current phasors measurements. Automation of Electric Power Systems, 2006, 24(1): 42-44.
    • (2006) Automation of Electric Power Systems , vol.24 , Issue.1 , pp. 42-44
    • Lu, Z.1    Xu, S.2    Shi, Z.3
  • 7
    • 0000562955 scopus 로고
    • Real time voltage-phasor measurements for static state estimation
    • THORP J S, PHADKE A G, KARIMI K J, et al. Real time voltage-phasor measurements for static state estimation. IEEE Trans on Power Systems, 1986, 1(1): 233-241.
    • (1986) IEEE Trans on Power Systems , vol.1 , Issue.1 , pp. 233-241
    • Thorp, J.S.1    Phadke, A.G.2    Karimi, K.J.3
  • 8
    • 0030313782 scopus 로고    scopus 로고
    • Implementation of PMU technology in static state estimation: An overview
    • Stellenbosch, South Africa. Piscataway, NJ, USA: IEEE, 1996: 1006-1011.
    • ZIVANOVIC R, CARNIS C. Implementation of PMU technology in static state estimation: an overview//Proceedings of 1996 IEEE African Conference: Vol 2, Sep 24-27, 1996, Stellenbosch, South Africa. Piscataway, NJ, USA: IEEE, 1996: 1006-1011.
    • (1996) Proceedings of 1996 IEEE African Conference , vol.2 , Issue.24-27
    • Zivanovic, R.1    Carnis, C.2
  • 9
  • 10
    • 8644267547 scopus 로고    scopus 로고
    • State estimation model with PMU current phasor measurements
    • ZHAO Hongga, XUE Yusheng, WANG Dexing, et al. State estimation model with PMU current phasor measurements. Automation of Electric Power Systems, 2004, 28(17): 37-40.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.17 , pp. 37-40
    • Zhao, H.1    Xue, Y.2    Wang, D.3
  • 11
    • 14944344685 scopus 로고    scopus 로고
    • Influence of measured values from phasor measurement units on equivalent current based measurement transform algorithm in state estimation
    • DING Junce, CAI Zexiang, WANG Keying. Influence of measured values from phasor measurement units on equivalent current based measurement transform algorithm in state estimation. Power System Technology, 2005, 29(5): 47-51.
    • (2005) Power System Technology , vol.29 , Issue.5 , pp. 47-51
    • Ding, J.1    Cai, Z.2    Wang, K.3
  • 12
    • 27544475531 scopus 로고    scopus 로고
    • A hybrid algorithm for power system state estimation based on PMU measurement and SCADA measurement
    • LI Qiang, ZHOU Jingyang, YU Erkeng, et al. A hybrid algorithm for power system state estimation based on PMU measurement and SCADA measurement. Automation of Electric Power Systems, 2005, 29(19): 31-35.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.19 , pp. 31-35
    • Li, Q.1    Zhou, J.2    Yu, E.3
  • 13
    • 26844510516 scopus 로고    scopus 로고
    • Power system linear estimation based on phasor measurements
    • LI Qiang, ZHOU Jingyang, YU Erkeng, et al. Power system linear estimation based on phasor measurements. Automation of Electric Power Systems, 2005, 29(18): 24-28.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.18 , pp. 24-28
    • Li, Q.1    Zhou, J.2    Yu, E.3
  • 14
    • 0035435349 scopus 로고    scopus 로고
    • Precision improvement and PMU placement studies on state estimation of a hybrid measurement system with PMUs
    • WANG Keying, MU Gang, CHEN Xueyun. Precision improvement and PMU placement studies on state estimation of a hybrid measurement system with PMUs. Proceedings of the CSEE, 2001, 21(8): 29-33.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.8 , pp. 29-33
    • Wang, K.1    Mu, G.2    Chen, X.3
  • 15
    • 3142537366 scopus 로고
    • Beijing: China Electric Power Publishing Press
    • ZHU Junwei. Power system analysis. Beijing: China Electric Power Publishing Press, 1995.
    • (1995) Power System Analysis
    • Zhu, J.1
  • 17
    • 34147201265 scopus 로고    scopus 로고
    • The assessment report of advanced applicable technologies: power system dynamic realtime monitoring technology
    • State Grid Corporation of China
    • State Grid Corporation of China. The assessment report of advanced applicable technologies: power system dynamic realtime monitoring technology [R/OL], [2006-04-02]. http://www.electricpower.cn/Newsread.asp?ID=804andPage=2.
    • (2006)