메뉴 건너뛰기




Volumn 60, Issue 4 SUPPL. 2, 2007, Pages

The use of multiplanar trajectory planning in the stereotactic placement of depth electrodes

Author keywords

Depth electrodes; Epilepsy; Hippocampus; Multiplanar imaging; Stereotactic neurosurgery

Indexed keywords

ADULT; AMYGDALOID NUCLEUS; ANATOMICAL VARIATION; ARTICLE; BRAIN DEPTH STIMULATION; COMPUTER PROGRAM; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ELECTRODE; EPILEPSY; FEMALE; HIPPOCAMPUS; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; STEREOTAXIC SURGERY; TREATMENT PLANNING;

EID: 34147195148     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000255390.92785.A4     Document Type: Article
Times cited : (12)

References (11)
  • 4
  • 6
    • 0027512505 scopus 로고
    • Stereotactic insertion of intracerebral electrodes in the investigation of epilepsy
    • Kratimenos GP, Thomas DG, Shorvon SD, Fish DR: Stereotactic insertion of intracerebral electrodes in the investigation of epilepsy. Br J Neurosurg 7:45-52, 1993.
    • (1993) Br J Neurosurg , vol.7 , pp. 45-52
    • Kratimenos, G.P.1    Thomas, D.G.2    Shorvon, S.D.3    Fish, D.R.4
  • 8
    • 0036108928 scopus 로고    scopus 로고
    • Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems - Technique and outcome
    • Murphy MA, O'Brien TJ, Cook MJ: Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems - Technique and outcome. Br J Neurosurg 16:119-125, 2002.
    • (2002) Br J Neurosurg , vol.16 , pp. 119-125
    • Murphy, M.A.1    O'Brien, T.J.2    Cook, M.J.3
  • 9
    • 0029954478 scopus 로고    scopus 로고
    • Intracerebral depth electrode monitoring in partial epilepsy: The morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery
    • Ross DA, Brunberg JA, Drury I, Henry TR: Intracerebral depth electrode monitoring in partial epilepsy: The morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery 39:327-334, 1996.
    • (1996) Neurosurgery , vol.39 , pp. 327-334
    • Ross, D.A.1    Brunberg, J.A.2    Drury, I.3    Henry, T.R.4
  • 10
    • 0034856853 scopus 로고    scopus 로고
    • Medically intractable, localization-related epilepsy with normal MRI: Presurgical evaluation and surgical outcome in 43 patients
    • Siegel AM, Jobst BC, Thadani VM, Rhodes CH, Lewis PJ, Roberts DW, Williamson PD: Medically intractable, localization-related epilepsy with normal MRI: Presurgical evaluation and surgical outcome in 43 patients. Epilepsia 42:883-888, 2001.
    • (2001) Epilepsia , vol.42 , pp. 883-888
    • Siegel, A.M.1    Jobst, B.C.2    Thadani, V.M.3    Rhodes, C.H.4    Lewis, P.J.5    Roberts, D.W.6    Williamson, P.D.7
  • 11
    • 0031720859 scopus 로고    scopus 로고
    • Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: Acomputed tomography-based stereotactic insertion technique and its accuracy
    • Van Roost D, Solymosi L, Schramm J, van Oosterwyck B, Elger CE: Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: Acomputed tomography-based stereotactic insertion technique and its accuracy. Neurosurgery 43:819-827, 1998.
    • (1998) Neurosurgery , vol.43 , pp. 819-827
    • Van Roost, D.1    Solymosi, L.2    Schramm, J.3    van Oosterwyck, B.4    Elger, C.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.