메뉴 건너뛰기




Volumn 22, Issue 1, 2007, Pages 472-480

Study on AC flashover performance and discharge process of polluted and iced IEC standard suspension insulator string

Author keywords

AC flashover performance; Discharge process; Iced insulator string; Icing; Icing stress product

Indexed keywords

ELECTRIC BREAKDOWN; ELECTRIC CONDUCTIVITY; ELECTRIC DISCHARGES; IMPURITIES; POLLUTION;

EID: 34147189573     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2006.876705     Document Type: Article
Times cited : (105)

References (31)
  • 1
    • 0029272709 scopus 로고
    • Flashover problems caused by ice build-up on insulators
    • Mar./Apr
    • M. Farzaneh and J. Kiernicki, "Flashover problems caused by ice build-up on insulators," IEEE Electr. Insul. Mag., vol. 11, no. 2, pp. 5-17, Mar./Apr. 1995.
    • (1995) IEEE Electr. Insul. Mag , vol.11 , Issue.2 , pp. 5-17
    • Farzaneh, M.1    Kiernicki, J.2
  • 2
    • 0141961382 scopus 로고
    • Flashover performance of insulators in the presence of short icicles
    • M. Farzaneh and O. T. Melo, "Flashover performance of insulators in the presence of short icicles," Int. J. Offshore Polar Eng., vol. 4, no. 2, pp. 112-118, 1994.
    • (1994) Int. J. Offshore Polar Eng , vol.4 , Issue.2 , pp. 112-118
    • Farzaneh, M.1    Melo, O.T.2
  • 3
    • 0030263670 scopus 로고    scopus 로고
    • The cold-fog test
    • Oct
    • W. A. Chisholm et al., "The cold-fog test," IEEE Trans. Power Del., vol. 11, no. 4, pp. 1874-1880, Oct. 1996.
    • (1996) IEEE Trans. Power Del , vol.11 , Issue.4 , pp. 1874-1880
    • Chisholm, W.A.1
  • 4
    • 0020165217 scopus 로고
    • Flashover tests on artificially iced insulators
    • Aug
    • M. D. Charneski, G. L. Gaibrois, and B. F. Whitney, "Flashover tests on artificially iced insulators," IEEE Trans. Power App. Syst., vol. PAS-101, no. 8, pp. 2429-2433, Aug. 1982.
    • (1982) IEEE Trans. Power App. Syst , vol.PAS-101 , Issue.8 , pp. 2429-2433
    • Charneski, M.D.1    Gaibrois, G.L.2    Whitney, B.F.3
  • 5
    • 0008308188 scopus 로고
    • AC flashover test at project UHV on ice-coated insulators
    • Nov./Dec
    • M. Kawai, "AC flashover test at project UHV on ice-coated insulators," IEEE Trans. Power App. Syst., vol. PAS-89, no. 8, pp. 1800-1804, Nov./Dec. 1970.
    • (1970) IEEE Trans. Power App. Syst , vol.PAS-89 , Issue.8 , pp. 1800-1804
    • Kawai, M.1
  • 6
    • 0042074894 scopus 로고
    • Artificial ice tests on transmission line insulators - A progress report
    • San Francisco, CA, A75-491-1
    • H. M. Schneider, "Artificial ice tests on transmission line insulators - A progress report," in Proc. IEEE Power Eng. Soc. Summer Meeting San Francisco, CA, 1975, pp. 347-353, A75-491-1.
    • (1975) Proc. IEEE Power Eng. Soc. Summer Meeting , pp. 347-353
    • Schneider, H.M.1
  • 7
    • 34147131692 scopus 로고    scopus 로고
    • Ice Accretion on Transmission Lines and Protection
    • X. Jiang and H. Yi, Ice Accretion on Transmission Lines and Protection. Beijing, China: China Power, 2002.
    • (2002) Beijing, China: China Power
    • Jiang, X.1    Yi, H.2
  • 8
    • 34147156629 scopus 로고    scopus 로고
    • Atmospheric Environment and External Electrical Insulation
    • C. Sun, W. Sima, and L. Shu, Atmospheric Environment and External Electrical Insulation. Beijing, China: China Power, 2002.
    • (2002) Beijing, China: China Power
    • Sun, C.1    Sima, W.2    Shu, L.3
  • 9
    • 23844442306 scopus 로고    scopus 로고
    • Chinese transmission line's icing characteristics and analysis of severe ice accidents
    • Toulon, France, Sep
    • X. Jiang and L. Shu et al., "Chinese transmission line's icing characteristics and analysis of severe ice accidents," in Proc. 14th Int. J. Offshore and Polar Engineering Conf., Toulon, France, Sep. 2004, pp. 921-926.
    • (2004) Proc. 14th Int. J. Offshore and Polar Engineering Conf , pp. 921-926
    • Jiang, X.1    Shu, L.2
  • 11
    • 84969848886 scopus 로고    scopus 로고
    • Study of flashover performance and voltage correction of DC insulator in icing districts of altitude of 2500 m and below
    • Kuming, China, Yunnan Sci. Technol
    • C. Sun and X. Jiang et al., "Study of flashover performance and voltage correction of DC insulator in icing districts of altitude of 2500 m and below," in Proc. Int. Conf. Power System Technology, Kuming, China, 2002, vol. 3, pp. 1871-1874, Yunnan Sci. Technol.
    • (2002) Proc. Int. Conf. Power System Technology , vol.3 , pp. 1871-1874
    • Sun, C.1    Jiang, X.2
  • 12
    • 0024188144 scopus 로고
    • AC flashover characteristics of EHV line insulators for high altitude contamination regions
    • presented at the
    • L. Gu et al., "AC flashover characteristics of EHV line insulators for high altitude contamination regions," presented at the Int. Conf. Properties Applicat. Dielect. Materials, 1988.
    • (1988) Int. Conf. Properties Applicat. Dielect. Materials
    • Gu, L.1
  • 13
    • 12544250136 scopus 로고    scopus 로고
    • Electrical behavior of high voltage insulator strings under rime ice
    • Chester, U.K
    • K. Kannus and K. Lahti, "Electrical behavior of high voltage insulator strings under rime ice," in Proc. 9th Int. Workshop Atmospheric Icing Structures, Chester, U.K., 2000, p. 8.
    • (2000) Proc. 9th Int. Workshop Atmospheric Icing Structures , pp. 8
    • Kannus, K.1    Lahti, K.2
  • 14
    • 0026191180 scopus 로고
    • Withstand voltage characteristics of insulator strings covered with snow or ice
    • Jul
    • H. Matsuda, H. Komuro, and K. Takasu, "Withstand voltage characteristics of insulator strings covered with snow or ice," IEEE Trans. Power Del., vol. 6, no. 3, pp. 1243-1250, Jul. 1991.
    • (1991) IEEE Trans. Power Del , vol.6 , Issue.3 , pp. 1243-1250
    • Matsuda, H.1    Komuro, H.2    Takasu, K.3
  • 15
    • 0027629159 scopus 로고
    • Long range transported pollution and conductivity on atmospheric ice on insulators
    • Jul
    • S. M. Fikke, J. E. Hanssen, and L. Rolfseng, "Long range transported pollution and conductivity on atmospheric ice on insulators," IEEE Trans. Power Del., vol. 8, no. 3, pp. 1311-1321, Jul. 1993.
    • (1993) IEEE Trans. Power Del , vol.8 , Issue.3 , pp. 1311-1321
    • Fikke, S.M.1    Hanssen, J.E.2    Rolfseng, L.3
  • 16
    • 0029291808 scopus 로고
    • AC flashover performance of insulators covered with artificial ice
    • Apr
    • M. Farzaneh and J. F. Drapeau, "AC flashover performance of insulators covered with artificial ice," IEEE Trans. Power Del., vol. 10, no. 2, pp. 1038-1051, Apr. 1995.
    • (1995) IEEE Trans. Power Del , vol.10 , Issue.2 , pp. 1038-1051
    • Farzaneh, M.1    Drapeau, J.F.2
  • 17
    • 0031258323 scopus 로고    scopus 로고
    • Flashover performance of IEEE standard insulators under ice conditions
    • Oct
    • M. Farzaneh and J. Kiernicki, "Flashover performance of IEEE standard insulators under ice conditions," IEEE Trans. Power Del., vol. 12, no. 4, pp. 1602-1613, Oct. 1997.
    • (1997) IEEE Trans. Power Del , vol.12 , Issue.4 , pp. 1602-1613
    • Farzaneh, M.1    Kiernicki, J.2
  • 18
    • 0008316738 scopus 로고
    • Effect of ice thickness and voltage polarity on the flashover voltage of ice-covered high-voltage insulators
    • Dresden, Germany
    • M. Farzaneh, "Effect of ice thickness and voltage polarity on the flashover voltage of ice-covered high-voltage insulators," in Proc. 7th Int. Symp. High Voltage Eng., Dresden, Germany, 1991, vol. 4, pp. 203-206.
    • (1991) Proc. 7th Int. Symp. High Voltage Eng , vol.4 , pp. 203-206
    • Farzaneh, M.1
  • 21
    • 0036698821 scopus 로고    scopus 로고
    • Study on AC flashover performance and process of ice-covered 10 kV composite insulator
    • X. Jiang and C. Sun et al., "Study on AC flashover performance and process of ice-covered 10 kV composite insulator," in Proc. CSEE 2002, vol. 22, no. 8, pp. 58-61.
    • (2002) Proc. CSEE , vol.22 , Issue.8 , pp. 58-61
    • Jiang, X.1    Sun, C.2
  • 23
    • 0011793862 scopus 로고
    • Flashover performance of transmission line insulators covered with salt-contaminated ice and icicle
    • Dresden, German
    • N. Suganara, S. Watanabe, and K. Hokara, "Flashover performance of transmission line insulators covered with salt-contaminated ice and icicle," in Proc. 7th Int. Symp. High Voltage Engineering, Dresden, German, 1991, pp. 291-294.
    • (1991) Proc. 7th Int. Symp. High Voltage Engineering , pp. 291-294
    • Suganara, N.1    Watanabe, S.2    Hokara, K.3
  • 24
    • 10744224017 scopus 로고    scopus 로고
    • Insulator icing test methods and procedures - A position paper prepared by the IEEE task force on insulator icing test methods
    • Oct
    • M. Farzaneh and T. Baker et al., "Insulator icing test methods and procedures - A position paper prepared by the IEEE task force on insulator icing test methods," IEEE Trans. Power Del., vol. 18, no. 4, pp. 1503-1515, Oct. 2003.
    • (2003) IEEE Trans. Power Del , vol.18 , Issue.4 , pp. 1503-1515
    • Farzaneh, M.1    Baker, T.2
  • 25
    • 0032657399 scopus 로고    scopus 로고
    • Ice-covering with artificial rime and discharge tests of 500 kV insulator strings
    • S. Jia, J. Wang, and G. Li, "Ice-covering with artificial rime and discharge tests of 500 kV insulator strings," in Proc. CSEE, 1999, vol. 19, no. 2, pp. 75-78.
    • (1999) Proc. CSEE , vol.19 , Issue.2 , pp. 75-78
    • Jia, S.1    Wang, J.2    Li, G.3
  • 26
    • 0002324691 scopus 로고    scopus 로고
    • Artificial ice tests for long insulator strings
    • Chicoutimi, QC, Canada
    • D. Wu, K. Halsan, and S. Fikke, "Artificial ice tests for long insulator strings," in Proc. 7th IWAIS, Chicoutimi, QC, Canada, 1996, pp. 67-71.
    • (1996) Proc. 7th IWAIS , pp. 67-71
    • Wu, D.1    Halsan, K.2    Fikke, S.3
  • 27
    • 0020950943 scopus 로고
    • Minimum flashover voltage of iced insulators
    • Dec
    • L. C. Phan and H. Matsuo, "Minimum flashover voltage of iced insulators," IEEE Trans. Electr. Insul., vol. EI-18, no. 6, pp. 605-618, Dec. 1983.
    • (1983) IEEE Trans. Electr. Insul , vol.EI-18 , Issue.6 , pp. 605-618
    • Phan, L.C.1    Matsuo, H.2
  • 28
    • 34147152683 scopus 로고    scopus 로고
    • IEC, Artificial Pollution Tests on High Voltage Insulators to be Used on AC Systems IEC International Standard, Publication 507, 1991.
    • IEC, Artificial Pollution Tests on High Voltage Insulators to be Used on AC Systems IEC International Standard, Publication 507, 1991.
  • 30
    • 12544259669 scopus 로고    scopus 로고
    • The icing stress product: A measure for testing and design of outdoor insulators in freezing conditions
    • Tottori, Japan
    • W. A. Chisholm, J. Kuffel, and M. Farzaneh, "The icing stress product: a measure for testing and design of outdoor insulators in freezing conditions," in Proc. 2nd Int. Workshop on High Voltage Engineering Tottori, Japan, 2000.
    • (2000) Proc. 2nd Int. Workshop on High Voltage Engineering
    • Chisholm, W.A.1    Kuffel, J.2    Farzaneh, M.3
  • 31
    • 19944430793 scopus 로고    scopus 로고
    • Selection of station insulators with respect to ice and snow-part I: Technical context and environmental exposure
    • Jan
    • M. Farzaneh and T. Baker et al., "Selection of station insulators with respect to ice and snow-part I: Technical context and environmental exposure," IEEE Trans. Power Del., vol. 20, no. 1, pp. 264-270, Jan. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.1 , pp. 264-270
    • Farzaneh, M.1    Baker, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.