메뉴 건너뛰기




Volumn 22, Issue 2, 2007, Pages 744-751

The performance of strippable and bonded screened medium-voltage XLPE-insulated cables under long-term accelerated aging

Author keywords

Accelerated multifactor aging; Retained dielectric strength; Strippable and bonded screens; Vented and bow tie trees; Water tree statistics; XLPE cables

Indexed keywords

AGING OF MATERIALS; DEGRADATION; DIELECTRIC MATERIALS; ELECTRIC POWER UTILIZATION; INSULATING MATERIALS; SEMICONDUCTOR MATERIALS; THERMAL STRESS;

EID: 34147185238     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2007.893391     Document Type: Article
Times cited : (23)

References (10)
  • 1
    • 34147149168 scopus 로고    scopus 로고
    • Estimation of life expectancy of polyethylene insulated cables Electric Power Research Institute, Palo Alto, CA
    • EL-3154, 1984
    • N. N. Srinavas, Estimation of life expectancy of polyethylene insulated cables Electric Power Research Institute, Palo Alto, CA, EPRI Rep. EL-3154, 1984.
    • EPRI Rep
    • Srinavas, N.N.1
  • 4
    • 34147092193 scopus 로고    scopus 로고
    • Investigations of electrical breakdown in HV polymeric insulated cables and their accessories commonly used in Saudi Arabia King Abdulaziz City Sci. Technol
    • A. A. Al-Arainy, N. H. Malik, M. I. Qureshi, and N. Al-Saati, Investigations of electrical breakdown in HV polymeric insulated cables and their accessories commonly used in Saudi Arabia King Abdulaziz City Sci. Technol., Final Rep. AR-15-46, 2001.
    • (2001) Final Rep , vol.AR-15-46
    • Al-Arainy, A.A.1    Malik, N.H.2    Qureshi, M.I.3    Al-Saati, N.4
  • 5
    • 34147175624 scopus 로고    scopus 로고
    • Specification for Polyethylene and crosslinked polyethylene insulated shielded power cables rated 5-46 kV 10th ed. 1994, AEIC-CS5-1994
    • Specification for Polyethylene and crosslinked polyethylene insulated shielded power cables rated 5-46 kV 10th ed. 1994, AEIC-CS5-1994.
  • 6
    • 34147103434 scopus 로고
    • Influence of temperature on accelerated aging of XLPE and EPR insulated cables under wet conditions
    • Paper A8.5
    • B. S. Bernstein and R. W. Simm, "Influence of temperature on accelerated aging of XLPE and EPR insulated cables under wet conditions," in Proc. JICABLE, 1995, pp. 221-233, Paper A8.5.
    • (1995) Proc. JICABLE , pp. 221-233
    • Bernstein, B.S.1    Simm, R.W.2
  • 7
    • 0026851167 scopus 로고
    • Accelerated aging of extruded power cables, Part I, control and monitoring methodology
    • Apr
    • M. D. Walton, J. T. Smith, and W. A. Thue, "Accelerated aging of extruded power cables, Part I, control and monitoring methodology," IEEE Trans. Power Del., vol. 9, no. 2, pp. 596-602, Apr. 1992.
    • (1992) IEEE Trans. Power Del , vol.9 , Issue.2 , pp. 596-602
    • Walton, M.D.1    Smith, J.T.2    Thue, W.A.3
  • 10
    • 0024703246 scopus 로고
    • Characterization test and classification procedure for water tree aged medium voltage cables
    • E. F. Steenis and A. M. F. J. Van der Laar, "Characterization test and classification procedure for water tree aged medium voltage cables," Electra., no. 125, pp. 89-101, 1989.
    • (1989) Electra , Issue.125 , pp. 89-101
    • Steenis, E.F.1    Van der Laar, A.M.F.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.