Volumn 3, Issue 3 SPEC. ISS., 2007, Pages 383-389

Modeling wear of cast Ti alloys

Author keywords

Contact stress field; Dental alloys; Structure property relations; Wear

Indexed keywords

DENTAL ALLOYS; DUCTILITY; ELASTOPLASTICITY; FRACTURE TOUGHNESS; HARDNESS; MICROSTRUCTURE; TITANIUM ALLOYS; WEAR OF MATERIALS;

EID: 34147171629     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2006.10.007     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 0028891962 scopus 로고
    • The use of titanium in dentistry
    • Okabe T., and Hero H. The use of titanium in dentistry. Cells Mater 5 (1995) 211-230
    • (1995) Cells Mater , vol.5 , pp. 211-230
    • Okabe, T.1    Hero, H.2
  • 2
    • 34147146988 scopus 로고    scopus 로고
    • Kustas FM, Misra MS, Friction and wear of titanium alloys. In: ASM Handbook 1992, Vol. 18: Friction, Lubrication and wear technology (ASM Handbook Committee, ed.); Materials Park, OH: ASM International; p. 778.
  • 3
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - a materials science perspective
    • Long M., and Rack H.J. Titanium alloys in total joint replacement - a materials science perspective. Biomaterials 19 (1998) 1621-1639
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 4
    • 0038181497 scopus 로고    scopus 로고
    • Studies on attrition of CP titanium as metal teeth
    • Kabe S. Studies on attrition of CP titanium as metal teeth. Tsurumi Univ Dent J 24 (1998) 69-79
    • (1998) Tsurumi Univ Dent J , vol.24 , pp. 69-79
    • Kabe, S.1
  • 5
    • 12444289667 scopus 로고    scopus 로고
    • In vitro study evaluating the relative wear resistance of CP titanium and artificial teeth materials
    • Shimura I. In vitro study evaluating the relative wear resistance of CP titanium and artificial teeth materials. Tsurumi Univ Dent J 27 (2001) 45-58
    • (2001) Tsurumi Univ Dent J , vol.27 , pp. 45-58
    • Shimura, I.1
  • 6
    • 0029329161 scopus 로고
    • Mixed-metal fretting corrosion of Ti-6Al-4V and wrought cobalt alloy
    • Kawalec J.S., Brown S.A., Payer J.H., and Merritt K. Mixed-metal fretting corrosion of Ti-6Al-4V and wrought cobalt alloy. J Biomed Mater Res 29 (1995) 867-873
    • (1995) J Biomed Mater Res , vol.29 , pp. 867-873
    • Kawalec, J.S.1    Brown, S.A.2    Payer, J.H.3    Merritt, K.4
  • 10
    • 1842764668 scopus 로고    scopus 로고
    • The grindability and wear of Ti-Cu alloys for dental applications
    • Okabe T., Kikuchi M., Ohkubo C., Koike M., Okuno O., and Oda Y. The grindability and wear of Ti-Cu alloys for dental applications. J Metals 56 (2004) 46-48
    • (2004) J Metals , vol.56 , pp. 46-48
    • Okabe, T.1    Kikuchi, M.2    Ohkubo, C.3    Koike, M.4    Okuno, O.5    Oda, Y.6
  • 11
    • 0035705835 scopus 로고    scopus 로고
    • A fracture mechanics approach to high cycle fretting fatigue based on the worst case fret concept
    • Chan K.S., Lee Y.D., Davidson D.L., and Hudak Jr. S.J. A fracture mechanics approach to high cycle fretting fatigue based on the worst case fret concept. Int J Fract 112 (2001) 299-330
    • (2001) Int J Fract , vol.112 , pp. 299-330
    • Chan, K.S.1    Lee, Y.D.2    Davidson, D.L.3    Hudak Jr., S.J.4
  • 12
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surface
    • Archard J.F. Contact and rubbing of flat surface. J Appl Phys 24 (1953) 981-988
    • (1953) J Appl Phys , vol.24 , pp. 981-988
    • Archard, J.F.1
  • 13
    • 0016452664 scopus 로고
    • The role of fracture toughness in the wear of metals
    • Honbogen E. The role of fracture toughness in the wear of metals. Wear 33 (1975) 251-259
    • (1975) Wear , vol.33 , pp. 251-259
    • Honbogen, E.1
  • 14
    • 0024087504 scopus 로고    scopus 로고
    • On fretting maps
    • Vingsbo O., and Säderberg S. On fretting maps. Wear 126 (1998) 131-147
    • (1998) Wear , vol.126 , pp. 131-147
    • Vingsbo, O.1    Säderberg, S.2
  • 15
    • 0025060514 scopus 로고
    • Fretting maps and fretting behavior of some f.c.c. metal alloys
    • Vingsbo O., Odfalk M., and Shen N.-E. Fretting maps and fretting behavior of some f.c.c. metal alloys. Wear 138 (1990) 153-156
    • (1990) Wear , vol.138 , pp. 153-156
    • Vingsbo, O.1    Odfalk, M.2    Shen, N.-E.3
  • 16
    • 0037376633 scopus 로고    scopus 로고
    • Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses
    • Iijima D., Yoneyama T., Doi T.H., Hamanaka H., and Kurosaki N. Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses. Biomaterials 24 (2003) 1519-1524
    • (2003) Biomaterials , vol.24 , pp. 1519-1524
    • Iijima, D.1    Yoneyama, T.2    Doi, T.H.3    Hamanaka, H.4    Kurosaki, N.5
  • 17
    • 34147189063 scopus 로고    scopus 로고
    • Koike M, Chan KS, Okabe T. Dental titanium casting at Baylor College of Dentistry - update. In: Proceedings of innovations in titanium technology symposium. Warrendale, PA: TMS; 2007, in press.
  • 19
    • 1542314838 scopus 로고    scopus 로고
    • Cytotoxicity of commercial and novel binary titanium alloys with and without a surface-reaction layer
    • Watanabe I., Wataha J.C., Lockwood P.E., Shimizu H., Cai Z., and Okabe T. Cytotoxicity of commercial and novel binary titanium alloys with and without a surface-reaction layer. J Oral Rehab 31 (2004) 185-189
    • (2004) J Oral Rehab , vol.31 , pp. 185-189
    • Watanabe, I.1    Wataha, J.C.2    Lockwood, P.E.3    Shimizu, H.4    Cai, Z.5    Okabe, T.6
  • 20
    • 0037210057 scopus 로고    scopus 로고
    • Electrochemical characterization of cast titanium alloys
    • Cai Z., Shafer T., Watanabe I., Nunn M.E., and Okabe T. Electrochemical characterization of cast titanium alloys. Biomaterials 24 (2003) 213-218
    • (2003) Biomaterials , vol.24 , pp. 213-218
    • Cai, Z.1    Shafer, T.2    Watanabe, I.3    Nunn, M.E.4    Okabe, T.5
  • 23
    • 0029178725 scopus 로고
    • Titanium framework removable partial denture sued for patients allergic to other metals: a clinical report and literature review
    • Kononen M., Rintanen J., Waltimo A., and Kempainen P. Titanium framework removable partial denture sued for patients allergic to other metals: a clinical report and literature review. J Prosthet Dent 73 (1995) 4-7
    • (1995) J Prosthet Dent , vol.73 , pp. 4-7
    • Kononen, M.1    Rintanen, J.2    Waltimo, A.3    Kempainen, P.4
  • 24
    • 0029375103 scopus 로고
    • Stereo laser-welded titanium implant frameworks: clinical and laboratory procedures with a summary of 1-year clinical trials
    • Rubenstein J.E. Stereo laser-welded titanium implant frameworks: clinical and laboratory procedures with a summary of 1-year clinical trials. J Prosthet Dent 74 (1995) 284-293
    • (1995) J Prosthet Dent , vol.74 , pp. 284-293
    • Rubenstein, J.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.