메뉴 건너뛰기




Volumn 52, Issue 8, 2007, Pages 2197-2211

High-resolution CT by diffraction-enhanced x-ray imaging: Mapping of breast tissue samples and comparison with their histo-pathology

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTERIZED TOMOGRAPHY; HISTOLOGY; PATHOLOGY; RADIOLOGY; TISSUE; X RAY DIFFRACTION;

EID: 34147166493     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/8/011     Document Type: Article
Times cited : (102)

References (37)
  • 2
    • 0034108783 scopus 로고    scopus 로고
    • Mammography with synchrotron radiation: Phase-detection techniques
    • Arfelli F et al 2000 Mammography with synchrotron radiation: phase-detection techniques Radiology 215 286-93
    • (2000) Radiology , vol.215 , Issue.1 , pp. 286-293
    • Arfelli, F.1    Al, E.2
  • 3
    • 33947407968 scopus 로고    scopus 로고
    • Synchrotron radiation mammography: Clinical experimentation
    • Arfelli F et al 2007 Synchrotron radiation mammography: clinical experimentation AIP Conf. Proc. 879 1895
    • (2007) AIP Conf. Proc. , vol.879 , pp. 1895
    • Arfelli, F.1    Al, E.2
  • 4
    • 0032886446 scopus 로고    scopus 로고
    • Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment
    • Boone J M 1999 Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment Radiology 213 23-37
    • (1999) Radiology , vol.213 , Issue.1 , pp. 23-37
    • Boone, J.M.1
  • 5
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • Boone J M, Nelson T R, Lindfors K K and Seibert J A 2001 Dedicated breast CT: radiation dose and image quality evaluation Radiology 221 657-67
    • (2001) Radiology , vol.221 , Issue.3 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 6
    • 0043013183 scopus 로고    scopus 로고
    • Comparison between a position sensitive germanium detector and a taper optics CCD 'FRELON' camera for diffraction enhanced imaging
    • Bravin A, Fiedler S, Coan P, Labiche J C, Ponchut C, Peterzol A and Thomlinson W 2003 Comparison between a position sensitive germanium detector and a taper optics CCD 'FRELON' camera for diffraction enhanced imaging Nucl. Instrum. Methods Phys. Res. A 510 35-40
    • (2003) Nucl. Instrum. Methods Phys. Res. , vol.510 , Issue.1-2 , pp. 35-40
    • Bravin, A.1    Fiedler, S.2    Coan, P.3    Labiche, J.C.4    Ponchut, C.5    Peterzol, A.6    Thomlinson, W.7
  • 8
    • 33745168307 scopus 로고    scopus 로고
    • Evaluation of image performance of a taper optics CCD 'FReLoN' camera designed for medical imaging
    • Coan P, Peterzol A, Fiedler S, Ponchut C, Labiche J C and Bravin A 2006 Evaluation of image performance of a taper optics CCD 'FReLoN' camera designed for medical imaging J. Synchrotron Radiat. 13 260-70
    • (2006) J. Synchrotron Radiat. , vol.13 , pp. 260-270
    • Coan, P.1    Peterzol, A.2    Fiedler, S.3    Ponchut, C.4    Labiche, J.C.5    Bravin, A.6
  • 12
    • 21344457725 scopus 로고    scopus 로고
    • Human breast cancer in vitro: Matching histo-pathology with small-angle x-ray scattering and diffraction enhanced x-ray imaging
    • Fernández M et al 2005 Human breast cancer in vitro: matching histo-pathology with small-angle x-ray scattering and diffraction enhanced x-ray imaging Phys. Med. Biol. 50 2991-3006
    • (2005) Phys. Med. Biol. , vol.50 , Issue.13 , pp. 2991-3006
    • Al Et, F.M.1
  • 15
    • 0025140589 scopus 로고
    • Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size
    • Grosswendt B 1990 Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size Phys. Med. Biol. 35 1233-45
    • (1990) Phys. Med. Biol. , vol.35 , Issue.9 , pp. 1233-1245
    • Grosswendt, B.1
  • 17
    • 73649188974 scopus 로고
    • A polychrome stain for differentiating pre-collagen from collagen
    • Herovici C 1963 A polychrome stain for differentiating pre-collagen from collagen Stain Technol. 38 204-5
    • (1963) Stain Technol. , vol.38 , pp. 204-205
    • Herovici, C.1
  • 18
    • 33748097996 scopus 로고    scopus 로고
    • Refraction contrast 11×-magnified x-ray imaging of large objects by MIRRORCLE-type table-top synchrotron
    • Hirai T et al 2006 Refraction contrast 11×-magnified x-ray imaging of large objects by MIRRORCLE-type table-top synchrotron J. Synchrotron Rad. 13 397-402
    • (2006) J. Synchrotron Rad. , vol.13 , pp. 397-402
    • Hirai, T.1    Al, E.2
  • 20
    • 84943271731 scopus 로고
    • X-ray plane-wave topography observation of the phase contrast from a non-crystalline object
    • Ingal V N and Beliaevskaya E A 1995 X-ray plane-wave topography observation of the phase contrast from a non-crystalline object J. Phys. D: Appl. Phys. 28 2314-7
    • (1995) J. Phys. D: Appl. Phys. , vol.28 , Issue.11 , pp. 2314-2317
    • Ingal, V.N.1    Beliaevskaya, E.A.2
  • 21
    • 0005113527 scopus 로고    scopus 로고
    • Imaging of biological objects in the plane-wave diffraction scheme
    • Ingal V N and Beliaevskaya E A 1997 Imaging of biological objects in the plane-wave diffraction scheme Il Nuovo Cimento 19D 553-60
    • (1997) Il Nuovo Cimento , vol.19 , pp. 553-560
    • Ingal, V.N.1    Beliaevskaya, E.A.2
  • 25
    • 0037423537 scopus 로고    scopus 로고
    • Measurement of image contrast using diffraction enhanced imaging
    • Kiss M Z, Sayers D E and Zhong Z 2003 Measurement of image contrast using diffraction enhanced imaging Phys. Med. Biol. 48 325-40
    • (2003) Phys. Med. Biol. , vol.48 , Issue.3 , pp. 325-340
    • Kiss, M.Z.1    Sayers, D.E.2    Zhong, Z.3
  • 26
    • 34147114881 scopus 로고    scopus 로고
    • Lyncean Technologies 2006 Company Information-News & Events (Lyncean Technologies, Inc., Pab Alto, CA) (updated 18 July 2006, cited 16 October 2006) http://www.lynceantech.com/company_news.html
    • (2006) Company Information-News & Events
    • Technologies, L.1
  • 27
    • 0034532771 scopus 로고    scopus 로고
    • Objective comparison of image quality and dose between conventional and synchrotron radiation mammography
    • Moeckli R, Verdun F R, Fiedler S, Pachoud M, Schnyder P and Valley J F 2000 Objective comparison of image quality and dose between conventional and synchrotron radiation mammography Phys. Med. Biol. 45 3509-23
    • (2000) Phys. Med. Biol. , vol.45 , Issue.12 , pp. 3509-3523
    • Moeckli, R.1    Verdun, F.R.2    Fiedler, S.3    Pachoud, M.4    Schnyder, P.5    Valley, J.F.6
  • 29
    • 0942265254 scopus 로고    scopus 로고
    • NHSBSP (National Health Service Breast Screening Programmes) 2000 Guidelines on Quality Assurance Visits (NHSBSP Publication No 40) (Sheffield: NHSBSP Publications)
    • (2000) Guidelines on Quality Assurance Visits
  • 30
    • 2542506560 scopus 로고    scopus 로고
    • Breast tomography with synchrotron radiation: Preliminary results
    • Pani S et al 2004 Breast tomography with synchrotron radiation: preliminary results Phys. Med. Biol. 49 1739-54
    • (2004) Phys. Med. Biol. , vol.49 , Issue.9 , pp. 1739-1754
    • Pani, S.1    Al, E.2
  • 31
    • 0034049264 scopus 로고    scopus 로고
    • Human breast cancer specimens: Diffraction-enhanced imaging with histologic correlation-improved conspicuity of lesion detail compared with digital radiography
    • Pisano E D et al 2000 Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation-improved conspicuity of lesion detail compared with digital radiography Radiology 214 895-901
    • (2000) Radiology , vol.214 , Issue.3 , pp. 895-901
    • Pisano, E.D.1    Al, E.2
  • 34
    • 0037769111 scopus 로고    scopus 로고
    • Medical applications of synchrotron radiation
    • Suortti P and Thomlinson W 2003 Medical applications of synchrotron radiation Phys. Med. Biol. 48 R1-35
    • (2003) Phys. Med. Biol. , vol.48 , Issue.13 , pp. 1-35
    • Suortti, P.1    Thomlinson, W.2
  • 37
    • 0034636898 scopus 로고    scopus 로고
    • Implementation of diffraction enhanced imaging experiments: At the NSLS and APS
    • Zhong Z, Thomlinson W, Chapman D and Sayers D 2000 Implementation of diffraction enhanced imaging experiments: at the NSLS and APS Nucl. Instrum. Methods Phys. Res. A 450 556-67
    • (2000) Nucl. Instrum. Methods Phys. Res. , vol.450 , Issue.2-3 , pp. 556-567
    • Zhong, Z.1    Thomlinson, W.2    Chapman, D.3    Sayers, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.