메뉴 건너뛰기




Volumn 14, Issue 5, 2007, Pages 613-624

Image Quality of the Aortic and Mitral Valve With CT:. Relative Versus Absolute Delay Reconstruction

Author keywords

aortic value; Cardiac CT; mitral value; reconstruction technique

Indexed keywords

CONTRAST MEDIUM;

EID: 34147154853     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2007.02.002     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 12244249215 scopus 로고    scopus 로고
    • Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart
    • Flohr T., Kuttner A., Bruder H., et al. Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart. Herz 28 (2003) 7-19
    • (2003) Herz , vol.28 , pp. 7-19
    • Flohr, T.1    Kuttner, A.2    Bruder, H.3
  • 2
    • 27744495083 scopus 로고    scopus 로고
    • Dynamic cine imaging of the mitral valve with 16-MDCT: A feasibility study
    • Alkadhi H., Bettex D., Wildermuth S., et al. Dynamic cine imaging of the mitral valve with 16-MDCT: A feasibility study. AJR Am J Roentgenol 185 (2005) 636-646
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 636-646
    • Alkadhi, H.1    Bettex, D.2    Wildermuth, S.3
  • 3
    • 31344447284 scopus 로고    scopus 로고
    • Quantification of mitral regurgitation with 16-channel multi-detector row computed tomography
    • Alkadhi H., Wildermuth S., Bettex D.A., et al. Quantification of mitral regurgitation with 16-channel multi-detector row computed tomography. Radiology 238 (2006) 454-463
    • (2006) Radiology , vol.238 , pp. 454-463
    • Alkadhi, H.1    Wildermuth, S.2    Bettex, D.A.3
  • 4
    • 33745727974 scopus 로고    scopus 로고
    • Assessment of the mitral valve area in patients with mitral stenosis by multislice computed tomography
    • Messika-Zeitoun D., Serfaty J.M., Laissy J.P., et al. Assessment of the mitral valve area in patients with mitral stenosis by multislice computed tomography. J Am Coll Cardiol 48 (2006) 411-413
    • (2006) J Am Coll Cardiol , vol.48 , pp. 411-413
    • Messika-Zeitoun, D.1    Serfaty, J.M.2    Laissy, J.P.3
  • 5
    • 25844483994 scopus 로고    scopus 로고
    • Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography
    • Baumert B., Plass A., Bettex D., et al. Dynamic cine mode imaging of the normal aortic valve using 16-channel multidetector row computed tomography. Invest Radiol 40 (2005) 637-647
    • (2005) Invest Radiol , vol.40 , pp. 637-647
    • Baumert, B.1    Plass, A.2    Bettex, D.3
  • 6
    • 33745184670 scopus 로고    scopus 로고
    • Aortic stenosis: Comparative evaluation of 16-detector row CT and echocardiography
    • Alkadhi H., Wildermuth S., Plass A., et al. Aortic stenosis: Comparative evaluation of 16-detector row CT and echocardiography. Radiology 240 (2006) 47-55
    • (2006) Radiology , vol.240 , pp. 47-55
    • Alkadhi, H.1    Wildermuth, S.2    Plass, A.3
  • 7
    • 33845285317 scopus 로고    scopus 로고
    • Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography
    • Bouvier E., Logeart D., Sablayrolles J.L., et al. Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. Eur Heart J (2006)
    • (2006) Eur Heart J
    • Bouvier, E.1    Logeart, D.2    Sablayrolles, J.L.3
  • 8
    • 33645401875 scopus 로고    scopus 로고
    • Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity
    • Feuchtner G.M., Dichtl W., Friedrich G.J., et al. Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity. J Am Coll Cardiol 47 (2006) 1410-1417
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1410-1417
    • Feuchtner, G.M.1    Dichtl, W.2    Friedrich, G.J.3
  • 9
    • 33745491628 scopus 로고    scopus 로고
    • Diagnostic performance of MDCT for detecting aortic valve regurgitation
    • Feuchtner G.M., Dichtl W., Schachner T., et al. Diagnostic performance of MDCT for detecting aortic valve regurgitation. AJR Am J Roentgenol 186 (2006) 1676-1681
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 1676-1681
    • Feuchtner, G.M.1    Dichtl, W.2    Schachner, T.3
  • 10
    • 27744521343 scopus 로고    scopus 로고
    • Multislice CT coronary angiography: How to do it and what is the current clinical performance?
    • Cademartiri F., Schuijf J.D., Mollet N.R., et al. Multislice CT coronary angiography: How to do it and what is the current clinical performance?. Eur J Nucl Med Mol Imaging 32 (2005) 1337-1347
    • (2005) Eur J Nucl Med Mol Imaging , vol.32 , pp. 1337-1347
    • Cademartiri, F.1    Schuijf, J.D.2    Mollet, N.R.3
  • 11
    • 14244259420 scopus 로고    scopus 로고
    • Non-invasive multislice CT coronary imaging
    • Mollet N.R., Cademartiri F., and de Feyter P.J. Non-invasive multislice CT coronary imaging. Heart 91 (2005) 401-407
    • (2005) Heart , vol.91 , pp. 401-407
    • Mollet, N.R.1    Cademartiri, F.2    de Feyter, P.J.3
  • 12
    • 0032603548 scopus 로고    scopus 로고
    • Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers
    • Kalender W.A., Wolf H., Suess C., Gies M., Greess H., and Bautz W.A. Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers. Eur Radiol 9 (1999) 323-328
    • (1999) Eur Radiol , vol.9 , pp. 323-328
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3    Gies, M.4    Greess, H.5    Bautz, W.A.6
  • 13
    • 29344476149 scopus 로고    scopus 로고
    • Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality
    • Herzog C., Arning-Erb M., Zangos S., et al. Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality. Radiology 238 (2006) 75-86
    • (2006) Radiology , vol.238 , pp. 75-86
    • Herzog, C.1    Arning-Erb, M.2    Zangos, S.3
  • 14
    • 0036373605 scopus 로고    scopus 로고
    • New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
    • Flohr T., Bruder H., Stierstorfer K., Simon J., Schaller S., and Ohnesorge B. New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174 (2002) 1022-1027
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , pp. 1022-1027
    • Flohr, T.1    Bruder, H.2    Stierstorfer, K.3    Simon, J.4    Schaller, S.5    Ohnesorge, B.6
  • 15
    • 0032604360 scopus 로고    scopus 로고
    • A PC program for estimating organ dose and effective dose values in computed tomography
    • Kalender W.A., Schmidt B., Zankl M., and Schmidt M. A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9 (1999) 555-562
    • (1999) Eur Radiol , vol.9 , pp. 555-562
    • Kalender, W.A.1    Schmidt, B.2    Zankl, M.3    Schmidt, M.4
  • 16
    • 0036834823 scopus 로고    scopus 로고
    • Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: Influence of physiological and technical prerequisite on image quality
    • Herzog C., Abolmaali N., Balzer J.O., et al. Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: Influence of physiological and technical prerequisite on image quality. Eur Radiol 12 (2002) 2670-2678
    • (2002) Eur Radiol , vol.12 , pp. 2670-2678
    • Herzog, C.1    Abolmaali, N.2    Balzer, J.O.3
  • 17
    • 27744595305 scopus 로고    scopus 로고
    • Applicability of ECG-gated multislice helical CT to patients with atrial fibrillation
    • Sato T., Anno H., Kondo T., et al. Applicability of ECG-gated multislice helical CT to patients with atrial fibrillation. Circ Jpn 69 (2005) 1068-1073
    • (2005) Circ Jpn , vol.69 , pp. 1068-1073
    • Sato, T.1    Anno, H.2    Kondo, T.3
  • 18
    • 33746412045 scopus 로고    scopus 로고
    • Variability of aortic valve calcification measurement with multislice spiral computed tomography
    • Ruhl K.M., Das M., Koos R., et al. Variability of aortic valve calcification measurement with multislice spiral computed tomography. Invest Radiol 41 (2006) 370-373
    • (2006) Invest Radiol , vol.41 , pp. 370-373
    • Ruhl, K.M.1    Das, M.2    Koos, R.3
  • 19
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.