메뉴 건너뛰기




Volumn 34, Issue 4, 2007, Pages 1487-1495

Accuracy and stability of positioning in radiosurgery: Long term results of the Gamma Knife system

Author keywords

Accuracy of irradiation positions; Long term stability; Quality assurance; Radiosurgery; Stereotactic; Target point deviation

Indexed keywords

IRRADIATION; PHANTOMS; QUALITY ASSURANCE; RADIATION; RADIOTHERAPY;

EID: 34147136007     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2710949     Document Type: Article
Times cited : (35)

References (12)
  • 1
    • 0037234447 scopus 로고    scopus 로고
    • An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system
    • S. D. Chang, W. Main, D. P. Martin, I. C. Gibbs, and M. Heilbrun, " An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system., " Neurosurgery 52, 140-147 (2003).
    • (2003) Neurosurgery , vol.52 , pp. 140-147
    • Chang, S.D.1    Main, W.2    Martin, D.P.3    Gibbs, I.C.4    Heilbrun, M.5
  • 2
    • 0034037793 scopus 로고    scopus 로고
    • Quality assurance for an image-guided frameless radiosurgery system using radiochromic film
    • H. Shiomi, T. Inoue, and S. Nakamura, " Quality assurance for an image-guided frameless radiosurgery system using radiochromic film., " Radiat. Med. 18, 107-113 (2000).
    • (2000) Radiat. Med. , vol.18 , pp. 107-113
    • Shiomi, H.1    Inoue, T.2    Nakamura, S.3
  • 5
    • 85027225752 scopus 로고    scopus 로고
    • DIN 6875-1, Deutsche Norm, Januar 2004, Special radiotherapy equipment-Part 1: Percutaneous stereotactic radiotherapy, Basic performance characteristics and essential test methods.
    • DIN 6875-1, Deutsche Norm, Januar 2004, Special radiotherapy equipment-Part 1: Percutaneous stereotactic radiotherapy, Basic performance characteristics and essential test methods.
  • 6
    • 33749585610 scopus 로고    scopus 로고
    • Impact of target point deviation on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases
    • H. Treuer, M. Koch, M. Hoevels, S. Hunsche, K. Luyken, M. Maarouf, J. Voges, R. P. Müller, and V. Sturm, " Impact of target point deviation on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases., " Radiother. Oncol. 81, 25-32 (2006).
    • (2006) Radiother. Oncol. , vol.81 , pp. 25-32
    • Treuer, H.1    Koch, M.2    Hoevels, M.3    Hunsche, S.4    Luyken, K.5    Maarouf, M.6    Voges, J.7    Müller, R.P.8    Sturm, V.9
  • 8
    • 0032938177 scopus 로고    scopus 로고
    • Quality assurance for the Leksell gamma unit: Considering magnetic resonance image-distortion and delineation failure in the targeting of the internal auditory canal
    • A. Ertl, W. Saringer, K. Heimberger, and P. Kindl, " Quality assurance for the Leksell gamma unit: Considering magnetic resonance image-distortion and delineation failure in the targeting of the internal auditory canal., " Med. Phys. 26, 166-170 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 166-170
    • Ertl, A.1    Saringer, W.2    Heimberger, K.3    Kindl, P.4
  • 9
    • 0032706450 scopus 로고    scopus 로고
    • Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization
    • S. L. Meeks, F. J. Bova, J. M. Buatti, W. A. Friedman, B. Eyster, and A. Kendrick, " Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization., " Phys. Med. Biol. 44, 2777-2787 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2777-2787
    • Meeks, S.L.1    Bova, F.J.2    Buatti, J.M.3    Friedman, W.A.4    Eyster, B.5    Kendrick, A.6
  • 10
    • 0031707702 scopus 로고    scopus 로고
    • Quality assurance in LINAC-based stereotactic radiosurgery and radiotherapy
    • D. P. Rosenzweig, M. C. Schell, and Y. Numaguchi, " Quality assurance in LINAC-based stereotactic radiosurgery and radiotherapy., " Med. Dosim. 23, 147-151 (1998).
    • (1998) Med. Dosim. , vol.23 , pp. 147-151
    • Rosenzweig, D.P.1    Schell, M.C.2    Numaguchi, Y.3
  • 11
    • 0031664750 scopus 로고    scopus 로고
    • A quality assurance program in stereotactic radiosurgery using the Gamma Knife unit
    • G. F. Stuecklschweiger and K. Feichtinger, " A quality assurance program in stereotactic radiosurgery using the Gamma Knife unit., " Strahlenther. Onkol. 174, 43-46 (1998).
    • (1998) Strahlenther. Onkol. , vol.174 , pp. 43-46
    • Stuecklschweiger, G.F.1    Feichtinger, K.2
  • 12
    • 0035737050 scopus 로고    scopus 로고
    • Is distortion correction necessary for digital subtraction angiography in the Gamma Knife treatment of intra-cranial arteriovenous malformations?
    • J. Perks, E. J. St. George, D. Doughty, P. N. Plowmann, " Is distortion correction necessary for digital subtraction angiography in the Gamma Knife treatment of intra-cranial arteriovenous malformations?, " Stereotact. Funct. Neurosurg. 76, 94-105 (2001).
    • (2001) Stereotact. Funct. Neurosurg. , vol.76 , pp. 94-105
    • Perks, J.1    St., J.G.E.2    Doughty, D.3    Plowmann, P.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.