메뉴 건너뛰기




Volumn 14, Issue 2, 2007, Pages 334-340

Electric field effect on metallic particle contamination in a common enclosure gas insulated busduct

Author keywords

Electric field effects; Gas insulated substations; Metallic particles

Indexed keywords

COMPUTER SIMULATION; ELECTRIC FIELD EFFECTS; ELECTRIC INSULATION; ELECTRIC SUBSTATIONS; SURFACE PROPERTIES;

EID: 34147135034     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2007.344611     Document Type: Article
Times cited : (49)

References (8)
  • 1
    • 85041983673 scopus 로고
    • Recent Research in the United States on the Effect of Particle Contamination Reducing the Breakdown Voltage in Compressed Gas Insulated System
    • Paris
    • A.H. Cookson, P.C. Bolin, H.C. Doepken, R.E. Wootton, C.M. Cooke and J.G. Trump, "Recent Research in the United States on the Effect of Particle Contamination Reducing the Breakdown Voltage in Compressed Gas Insulated System", Int. Conf. On Large High Voltage System; Paris, 1976.
    • (1976) Int. Conf. On Large High Voltage System
    • Cookson, A.H.1    Bolin, P.C.2    Doepken, H.C.3    Wootton, R.E.4    Cooke, C.M.5    Trump, J.G.6
  • 2
    • 0343643588 scopus 로고
    • Breakdown Characteristics of Dielectric Coated Electrodes in Sulphur Hexafluoride Gas with Particle Contamination
    • Paper No. 32.06, New Orleans, LA, USA
    • H.Anis and K.D. Srivastava, "Breakdown Characteristics of Dielectric Coated Electrodes in Sulphur Hexafluoride Gas with Particle Contamination", Sixth Intern. Sympos High Voltage Engineering, Paper No. 32.06, New Orleans, LA, USA. 1989.
    • (1989) Sixth Intern. Sympos High Voltage Engineering
    • Anis, H.1    Srivastava, K.D.2
  • 3
    • 0034171758 scopus 로고    scopus 로고
    • Dynamics of Metallic particle contamination in GIS with dielectric coating electrodes
    • M.M. Morcos, S. Zhang, K.D. Srivastava, and S.M. Gubanski, "Dynamics of Metallic particle contamination in GIS with dielectric coating electrodes", IEEE Trans. Power Delivery Vol. 15, pp. 455- 460, 2000.
    • (2000) IEEE Trans. Power Delivery , vol.15 , pp. 455-460
    • Morcos, M.M.1    Zhang, S.2    Srivastava, K.D.3    Gubanski, S.M.4
  • 4
    • 0033342990 scopus 로고
    • Determination of particle trajectory in a Gas Insulated Busduct predicted by Monte-Carlo technique
    • Texas, Austin, USA
    • J. Amarnath, B. P. Singh, C. Radhakrishna and S. Kamakshiah, "Determination of particle trajectory in a Gas Insulated Busduct predicted by Monte-Carlo technique", IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP), Texas, Austin, USA, 1991 Vol. 1, pp. 399-402, 1991.
    • (1991) IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP) , vol.1 , pp. 399-402
    • Amarnath, J.1    Singh, B.P.2    Radhakrishna, C.3    Kamakshiah, S.4
  • 5
    • 34147148471 scopus 로고    scopus 로고
    • Influence of Power Frequency and Switching Impulse Voltage on Particle Movement in GIS - Predicted by Monte-Carlo Technique
    • California, USA
    • J. Amarnath, S. Kamakshaiah, B.P. Singh and K.D. Srivastava "Influence of Power Frequency and Switching Impulse Voltage on Particle Movement in GIS - Predicted by Monte-Carlo Technique", IEEE, Intern. High Voltage Workshop, California, USA, 2001.
    • (2001) IEEE, Intern. High Voltage Workshop
    • Amarnath, J.1    Kamakshaiah, S.2    Singh, B.P.3    Srivastava, K.D.4
  • 6
    • 0008969717 scopus 로고
    • Compressed gas insulation in large coaxial systems
    • H. C. Doepken Jr., "Compressed gas insulation in large coaxial systems", IEEE Trans. Power App. Syst., Vol. 88, pp. 364-369, 1969.
    • (1969) IEEE Trans. Power App. Syst , vol.88 , pp. 364-369
    • Doepken Jr., H.C.1
  • 7
    • 0019624856 scopus 로고
    • A review of particle contaminated gas breakdown
    • J. R. Laghari and A. H. Qureshi, "A review of particle contaminated gas breakdown", IEEE Trans. Electr. Insul., Vol, 16, pp.388-398, 1981.
    • (1981) IEEE Trans. Electr. Insul , vol.16 , pp. 388-398
    • Laghari, J.R.1    Qureshi, A.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.