Frequency domain near-infrared spectroscopy technique in the assessment of brain oxygenation: A validation study in live subjects and cadavers
Gatto R, Hoffman W, Mueller M, et al: Frequency domain near-infrared spectroscopy technique in the assessment of brain oxygenation: A validation study in live subjects and cadavers. J Neurosci Methods 2006; 157:274-277
Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry
Daubeney PE, Pilkington SN, Janke E, et al: Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry. Ann Thorac Surg 1996; 61:930-934
Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: A comparison with jugular venous bulb oximetry
Lewis SB, Myburgh JA, Thornton EL, et al: Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: A comparison with jugular venous bulb oximetry. Crit Care Med 1996; 24:1334-1338
A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
Tortoriello TA, Stayer SA, Mott AR, et al: A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Pediatr Anaesth 2005; 15:495-503
Brain tissue oxygenation index measured by near infrared spatially resolved spectroscopy agreed with jugular bulb oxygen saturation in normal pediatric brain: A pilot study
Shimizu N, Gilder F, Bissonnette B, et al: Brain tissue oxygenation index measured by near infrared spatially resolved spectroscopy agreed with jugular bulb oxygen saturation in normal pediatric brain: A pilot study. Childs Nerv Syst 2005; 21:181-1814
Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children
Nagdyman N, Fleck T, Schubert S, et al: Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med 2005; 31:846-850
Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery
Ali MS, Harmer M, Vaughan RS, et al: Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery. Can J Anaesth 2001; 48:497-501
Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: Concordance and association with clinical variables
McQuillen PS, Nishimoto MS, Bottrell CL, et al: Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: Concordance and association with clinical variables. Pediatr Crit Care Med 2007; 8:154-160
Tissue oxygenation monitoring during major pediatric surgery using transcutaneous liver near infrared spectroscopy
Weiss M, Schulz G, Teller I, et al: Tissue oxygenation monitoring during major pediatric surgery using transcutaneous liver near infrared spectroscopy. Paediatr Anaesth 2004; 14:989-995