메뉴 건너뛰기




Volumn 3, Issue , 2006, Pages 822-825

Image analysis of renal DCE-MRI for the detection of acute renal rejection

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; IMAGE REGISTRATION; MAGNETIC RESONANCE IMAGING; TISSUE; TRANSPLANTATION (SURGICAL); TRANSPLANTS;

EID: 34147096383     PISSN: 10514651     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICPR.2006.679     Document Type: Conference Paper
Times cited : (29)

References (7)
  • 1
    • 34147149472 scopus 로고    scopus 로고
    • U.S. Department of Health and Human Services. Annual report of the U.S. scientific registry of transplant recipients and the organ procurement and transplantation network: transplant data: 1990-1999. Bureau of Health Resources Department, Richmond, VA; 2000.
    • U.S. Department of Health and Human Services. Annual report of the U.S. scientific registry of transplant recipients and the organ procurement and transplantation network: transplant data: 1990-1999. Bureau of Health Resources Department, Richmond, VA; 2000.
  • 2
    • 0032850134 scopus 로고    scopus 로고
    • Magnetic, Magnetic resonance imaging in renal transplantation
    • Sep
    • M. Neimatallah, Q. Dong, S. Schoenberg, K. Cho, and M. Prince, "Magnetic, "Magnetic resonance imaging in renal transplantation," J Magn Reson Imaging, vol. 10, no. 3, pp. 357-368, Sep 1999.
    • (1999) J Magn Reson Imaging , vol.10 , Issue.3 , pp. 357-368
    • Neimatallah, M.1    Dong, Q.2    Schoenberg, S.3    Cho, K.4    Prince, M.5
  • 4
    • 0026875779 scopus 로고
    • Semiautomated ROI analysis in dynamic MRI studies: Part I: image analysis tools for automatic correction of organ displacements
    • G. Gerig, R. Kikinis, W. Kuoni, G.K. van Schulthess,and O. Kubler,"Semiautomated ROI analysis in dynamic MRI studies: Part I: image analysis tools for automatic correction of organ displacements," IEEE Trans. Image Processing, vol. 11, no. 2,pp. 221-232, 1992.
    • (1992) IEEE Trans. Image Processing , vol.11 , Issue.2 , pp. 221-232
    • Gerig, G.1    Kikinis, R.2    Kuoni, W.3    van Schulthess, G.K.4    Kubler, O.5
  • 5
    • 33750236236 scopus 로고    scopus 로고
    • Computer methods for semi-automatic MR renogram determination,
    • Ph.D. dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven
    • E. Giele, "Computer methods for semi-automatic MR renogram determination," Ph.D. dissertation, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, 2002.
    • (2002)
    • Giele, E.1
  • 7
    • 0029966538 scopus 로고    scopus 로고
    • Fast marching level set method for monotonically advancing fronts
    • Feb
    • J. A. Sethian, "Fast marching level set method for monotonically advancing fronts," Proc. Nat. Acad. Sci. USA, vol. 93, pp. 1591-1595, Feb. 1996.
    • (1996) Proc. Nat. Acad. Sci. USA , vol.93 , pp. 1591-1595
    • Sethian, J.A.1