메뉴 건너뛰기




Volumn 3565, Issue , 2005, Pages 603-614

Coil sensitivity estimation for optimal SNR reconstruction and intensity inhomogeneity correction in phased array MR imaging

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; DATA ACQUISITION; FUNCTIONS; IMAGE ANALYSIS; ITERATIVE METHODS; SIGNAL TO NOISE RATIO;

EID: 34047224433     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/11505730_50     Document Type: Conference Paper
Times cited : (35)

References (15)
  • 4
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity non-uniformity in MRI data
    • Sled, J.G., Zijdenbos, A.P., Evans, A.C.: A Nonparametric Method for Automatic Correction of Intensity Non-uniformity in MRI data. IEEE Transactions on Medical Imaging, 17:87-97, 1998.
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , pp. 87-97
    • Sled, J.G.1    Zijdenbos, A.P.2    Evans, A.C.3
  • 5
    • 0035112409 scopus 로고    scopus 로고
    • A multi-scale method for automatic correction of intensity non-uniformity in MR images
    • Han, C., Hatsukami, T.S., Yuan, C.: A Multi-scale Method for Automatic Correction of Intensity Non-Uniformity in MR Images. Journal of Magnetic Resonance Imaging, 13:428-436, 2001.
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , pp. 428-436
    • Han, C.1    Hatsukami, T.S.2    Yuan, C.3
  • 6
    • 0032880171 scopus 로고    scopus 로고
    • A fast model independent method for automatic correction of intensity non-uniformity in MRI data
    • Vokurka, E.A., Thacker, N.A., Jackson, A.: A Fast Model Independent Method for Automatic Correction of Intensity Non-uniformity in MRI Data. Journal of Magnetic Resonance Imaging, 10:550-562, 1999.
    • (1999) Journal of Magnetic Resonance Imaging , vol.10 , pp. 550-562
    • Vokurka, E.A.1    Thacker, N.A.2    Jackson, A.3
  • 9
    • 0023306810 scopus 로고
    • A new phase correction method in NMR imaging based on autocorrelation and histogram analysis
    • Ahn, C.B., Cho, Z.H.: A New Phase Correction Method in NMR Imaging Based on Autocorrelation and Histogram Analysis. IEEE Transactions on Medical Imaging, 6:32-36, 1987.
    • (1987) IEEE Transactions on Medical Imaging , vol.6 , pp. 32-36
    • Ahn, C.B.1    Cho, Z.H.2
  • 13
    • 0033201370 scopus 로고    scopus 로고
    • An adaptive segmentation algorithm of time-of-flight MRA data
    • Wilson, D.L., Noble, J.A.: An Adaptive Segmentation Algorithm of Time-of-flight MRA Data. IEEE Transactions on Medical Imaging, 18:938-945, 1999.
    • (1999) IEEE Transactions on Medical Imaging , vol.18 , pp. 938-945
    • Wilson, D.L.1    Noble, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.