메뉴 건너뛰기




Volumn , Issue , 2006, Pages 6113-6116

Probabilistic framework for reliability analysis of information-theoretic CAD systems in mammography

Author keywords

[No Author keywords available]

Indexed keywords

DIGITAL DATABASE FOR SCREENING MAMMOGRAPHY (DDSM); PROBABILISTIC FRAMEWORK; SCREENING MAMMOGRAMS;

EID: 34047176008     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2006.260500     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 1
    • 84882895823 scopus 로고    scopus 로고
    • Computer-aided detection and diagnosis in mammography
    • Elsevier Academic Press
    • M. P. Sampat, M. K. Markey, and A. C. Bovik, "Computer-aided detection and diagnosis in mammography," in Handbook of Image and Video Processing. Elsevier Academic Press, 2005, pp. 1195-1217.
    • (2005) Handbook of Image and Video Processing , pp. 1195-1217
    • Sampat, M.P.1    Markey, M.K.2    Bovik, A.C.3
  • 3
    • 0035088227 scopus 로고    scopus 로고
    • Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection
    • R. L. Birdwell, D. M. Ikeda, K. F. O'Shaughnessy, and E. A. Sickles, "Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection," Radiology, vol. 219, no. 1, pp. 192-202, 2001.
    • (2001) Radiology , vol.219 , Issue.1 , pp. 192-202
    • Birdwell, R.L.1    Ikeda, D.M.2    O'Shaughnessy, K.F.3    Sickles, E.A.4
  • 4
    • 0034860859 scopus 로고    scopus 로고
    • Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    • T. W. Freer and M. J. Ulissey, "Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center," Radiology, vol. 220, no. 3, pp. 781-786, 2001.
    • (2001) Radiology , vol.220 , Issue.3 , pp. 781-786
    • Freer, T.W.1    Ulissey, M.J.2
  • 5
    • 0035185843 scopus 로고    scopus 로고
    • Soft-copy mammographic readings with different computer-assisted detection cuing environments: Preliminary findings
    • B. Zheng, M. A. Ganott, C. A. Britton, C. M. Hakim, L. A. Hardesty, T. S. Chang, H. E. Rockette, and D. Gur, "Soft-copy mammographic readings with different computer-assisted detection cuing environments: preliminary findings," Radiology, vol. 221, no. 3, pp. 633-640, 2001.
    • (2001) Radiology , vol.221 , Issue.3 , pp. 633-640
    • Zheng, B.1    Ganott, M.A.2    Britton, C.A.3    Hakim, C.M.4    Hardesty, L.A.5    Chang, T.S.6    Rockette, H.E.7    Gur, D.8
  • 6
    • 1642462124 scopus 로고    scopus 로고
    • Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments
    • B. Zheng, R. G. Swensson, S. Golla, C. M. Hakim, R. Shah, L. Wallace, and D. Gur, "Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments," Acad. Radiol., vol. 11, no. 4, pp. 398-406, 2004.
    • (2004) Acad. Radiol , vol.11 , Issue.4 , pp. 398-406
    • Zheng, B.1    Swensson, R.G.2    Golla, S.3    Hakim, C.M.4    Shah, R.5    Wallace, L.6    Gur, D.7
  • 7
    • 1642350413 scopus 로고    scopus 로고
    • Computer-aided detection in clinical environment: Benefits and challenges for radiologists
    • E. A. Krupinski, "Computer-aided detection in clinical environment: benefits and challenges for radiologists," Radiology, vol. 231, no. 1, pp. 7-9, 2004.
    • (2004) Radiology , vol.231 , Issue.1 , pp. 7-9
    • Krupinski, E.A.1
  • 9
    • 0041387362 scopus 로고    scopus 로고
    • Computer-assisted detection of mammographic masses: A template matching scheme based on mutual information
    • G. D. Tourassi, R. Vargas-Voracek, D. M. Catarious, and C. E. Floyd, "Computer-assisted detection of mammographic masses: a template matching scheme based on mutual information." Med. Phys., vol. 30, no. 8, pp. 2123-2130, 2003.
    • (2003) Med. Phys , vol.30 , Issue.8 , pp. 2123-2130
    • Tourassi, G.D.1    Vargas-Voracek, R.2    Catarious, D.M.3    Floyd, C.E.4
  • 12
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • C. E. Metz, "Basic principles of ROC analysis," Semin. Nucl. Med., vol. 8, no. 4, pp. 283-298, 1978.
    • (1978) Semin. Nucl. Med , vol.8 , Issue.4 , pp. 283-298
    • Metz, C.E.1
  • 13
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • C. E. Metz, "ROC methodology in radiologic imaging," Invest. Radiol., vol. 21, no. 9, pp. 720-733, 1986.
    • (1986) Invest. Radiol , vol.21 , Issue.9 , pp. 720-733
    • Metz, C.E.1
  • 14
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • J. A. Hanley and B. J. McNeil, "The meaning and use of the area under a receiver operating characteristic (ROC) curve," Radiology, vol. 143, no. 1, pp. 29-36, 1982.
    • (1982) Radiology , vol.143 , Issue.1 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.