-
1
-
-
0029809781
-
Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo
-
Toussaint JF, LaMuraglia GM, Southern JF, Fuster V, Kantor HL. Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. Circulation 1996;94:932-938.
-
(1996)
Circulation
, vol.94
, pp. 932-938
-
-
Toussaint, J.F.1
LaMuraglia, G.M.2
Southern, J.F.3
Fuster, V.4
Kantor, H.L.5
-
2
-
-
0034185484
-
Characterization of atherosclerotic plaques by magnetic resonance imaging
-
Fayad ZA, Fuster V. Characterization of atherosclerotic plaques by magnetic resonance imaging. Ann NY Acad Sci 2000;902:173-186.
-
(2000)
Ann NY Acad Sci
, vol.902
, pp. 173-186
-
-
Fayad, Z.A.1
Fuster, V.2
-
3
-
-
0034756429
-
Carotid atherosclerotic plaque: Noninvasive MR characterization and identification of vulnerable lesions
-
Yuan C, Mitsumori LM, Beach KW, Maravilla KR. Carotid atherosclerotic plaque: noninvasive MR characterization and identification of vulnerable lesions. Radiology 2001;221:285-299.
-
(2001)
Radiology
, vol.221
, pp. 285-299
-
-
Yuan, C.1
Mitsumori, L.M.2
Beach, K.W.3
Maravilla, K.R.4
-
4
-
-
33644877105
-
In vivo quantitative measurement of intact fibrous cap and lipid-rich necrotic core size in atherosclerotic carotid plaque: Comparison of high-resolution, contrast-enhanced magnetic resonance imaging and histology
-
Cai J. Hatsukami TS, Ferguson MS, et al. In vivo quantitative measurement of intact fibrous cap and lipid-rich necrotic core size in atherosclerotic carotid plaque: comparison of high-resolution, contrast-enhanced magnetic resonance imaging and histology. Circulation 2005;112:3437-3444.
-
(2005)
Circulation
, vol.112
, pp. 3437-3444
-
-
Cai, J.1
Hatsukami, T.S.2
Ferguson, M.S.3
-
5
-
-
11144233333
-
Quantitative evaluation of carotid plaque composition by in vivo MRI
-
Saam T, Ferguson MS, Yarnykh VL, et al. Quantitative evaluation of carotid plaque composition by in vivo MRI. Arterioscler Thromb Vasc Biol 2005;25:234-239.
-
(2005)
Arterioscler Thromb Vasc Biol
, vol.25
, pp. 234-239
-
-
Saam, T.1
Ferguson, M.S.2
Yarnykh, V.L.3
-
6
-
-
0032832520
-
High-resolution three-dimensional in vivo imaging of atherosclerotic plaque
-
Luk-Pat GT, Gold GE, Olcott EW, Hu BS, Nishimura DG. High-resolution three-dimensional in vivo imaging of atherosclerotic plaque. Magn Reson Med 1999;42:762-771.
-
(1999)
Magn Reson Med
, vol.42
, pp. 762-771
-
-
Luk-Pat, G.T.1
Gold, G.E.2
Olcott, E.W.3
Hu, B.S.4
Nishimura, D.G.5
-
7
-
-
0038640448
-
Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement
-
Crowe LA, Gatehouse P, Yang GZ, et al. Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement. J Magn Reson Imaging 2003;17:572-580.
-
(2003)
J Magn Reson Imaging
, vol.17
, pp. 572-580
-
-
Crowe, L.A.1
Gatehouse, P.2
Yang, G.Z.3
-
8
-
-
33644835410
-
Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction
-
Crowe LA, Varghese A, Mohiaddin RH, Yang GZ, Firmin DN. Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction. J Magn Reson Imaging 2006;23:416-421.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 416-421
-
-
Crowe, L.A.1
Varghese, A.2
Mohiaddin, R.H.3
Yang, G.Z.4
Firmin, D.N.5
-
9
-
-
0031899393
-
On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation
-
Steinman DA, Rutt BK. On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation. Magn Reson Med 1998;39:635-641.
-
(1998)
Magn Reson Med
, vol.39
, pp. 635-641
-
-
Steinman, D.A.1
Rutt, B.K.2
-
10
-
-
33644835722
-
Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI
-
Boussel L, Herigault G, de la Vega A, Nonent M, Douek PC, Serfaty JM. Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI. J Magn Reson Imaging 2006;23: 413-415.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 413-415
-
-
Boussel, L.1
Herigault, G.2
de la Vega, A.3
Nonent, M.4
Douek, P.C.5
Serfaty, J.M.6
-
11
-
-
33845904636
-
Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls
-
Koktzoglou I, Li D. Diffusion-prepared segmented steady-state free precession: application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 2007;9:33-42.
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, pp. 33-42
-
-
Koktzoglou, I.1
Li, D.2
-
12
-
-
26244446227
-
3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing
-
Crowe LA, Keegan J, Gatehouse PD, et al. 3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing. J Magn Reson Imaging 2005;22:583-588.
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 583-588
-
-
Crowe, L.A.1
Keegan, J.2
Gatehouse, P.D.3
-
13
-
-
18044372018
-
Diffusion-weighted three-dimensional MP-RAGE MR imaging
-
Numano T, Homma K, Hirose T. Diffusion-weighted three-dimensional MP-RAGE MR imaging. Magn Reson Imaging 2005;23:463-468.
-
(2005)
Magn Reson Imaging
, vol.23
, pp. 463-468
-
-
Numano, T.1
Homma, K.2
Hirose, T.3
-
14
-
-
0028543887
-
Diffusion imaging with the MP-RAGE sequence
-
Lee H, Price RR. Diffusion imaging with the MP-RAGE sequence. J Magn Reson Imaging 1994;4:837-842.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 837-842
-
-
Lee, H.1
Price, R.R.2
-
15
-
-
0031809323
-
A quantitative method for fast diffusion imaging using magnetization-prepared TurboFLASH
-
Thomas DL, Pell GS, Lythgoe MF, Gadian DG, Ordidge RJ. A quantitative method for fast diffusion imaging using magnetization-prepared TurboFLASH. Magn Reson Med 1998;39:950-960.
-
(1998)
Magn Reson Med
, vol.39
, pp. 950-960
-
-
Thomas, D.L.1
Pell, G.S.2
Lythgoe, M.F.3
Gadian, D.G.4
Ordidge, R.J.5
-
16
-
-
0141506080
-
High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes
-
Jeong EK, Kim SE, Parker DL. High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes. Magn Reson Med 2003;50:821-829.
-
(2003)
Magn Reson Med
, vol.50
, pp. 821-829
-
-
Jeong, E.K.1
Kim, S.E.2
Parker, D.L.3
-
17
-
-
0031858491
-
Breath-hold T2-weighted MRI of hepatic tumors: Value of echo planar imaging with diffusion-sensitizing gradient
-
Okada Y, Ohtomo K, Kiryu S, Sasaki Y. Breath-hold T2-weighted MRI of hepatic tumors: value of echo planar imaging with diffusion-sensitizing gradient. J Comput Assist Tomogr 1998;22:364-371.
-
(1998)
J Comput Assist Tomogr
, vol.22
, pp. 364-371
-
-
Okada, Y.1
Ohtomo, K.2
Kiryu, S.3
Sasaki, Y.4
-
18
-
-
2942670674
-
Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging
-
Sirol M, Itskovich VV, Mani V, et al. Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging. Circulation 2004;109:2890-2896.
-
(2004)
Circulation
, vol.109
, pp. 2890-2896
-
-
Sirol, M.1
Itskovich, V.V.2
Mani, V.3
-
19
-
-
0026500233
-
Respiratory kinematics of the upper abdominal organs: A quantitative study
-
Korin HW, Ehman RL, Riederer SJ, Felmlee JP, Grimm RC. Respiratory kinematics of the upper abdominal organs: a quantitative study. Magn Reson Med 1992;23:172-178.
-
(1992)
Magn Reson Med
, vol.23
, pp. 172-178
-
-
Korin, H.W.1
Ehman, R.L.2
Riederer, S.J.3
Felmlee, J.P.4
Grimm, R.C.5
-
20
-
-
26844569237
-
Comparison of different flip angle variation functions for improved signal behavior in SSFP sequences
-
Kyoto, Japan, Abstract 2663
-
Paul D, Hennig J. Comparison of different flip angle variation functions for improved signal behavior in SSFP sequences. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004 (Abstract 2663).
-
(2004)
Proceedings of the 12th Annual Meeting of ISMRM
-
-
Paul, D.1
Hennig, J.2
-
21
-
-
27644437673
-
Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques
-
Mani V, Itskovich W, Aguiar SH, et al. Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques. J Magn Reson Imaging 2005;22:628-633.
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 628-633
-
-
Mani, V.1
Itskovich, W.2
Aguiar, S.H.3
-
22
-
-
0020623530
-
Pulsatile flow in a model carotid bifurcation
-
Ku DN, Giddens DP. Pulsatile flow in a model carotid bifurcation. Arteriosclerosis 1983;3:31-39.
-
(1983)
Arteriosclerosis
, vol.3
, pp. 31-39
-
-
Ku, D.N.1
Giddens, D.P.2
-
23
-
-
0021320947
-
Flow patterns in the human carotid artery bifurcation
-
Motomiya M, Karino T. Flow patterns in the human carotid artery bifurcation. Stroke 1984;15:50-56.
-
(1984)
Stroke
, vol.15
, pp. 50-56
-
-
Motomiya, M.1
Karino, T.2
-
24
-
-
0035063579
-
An automated segmentation method for three-dimensional carotid ultrasound images
-
Zahalka A, Fenster A. An automated segmentation method for three-dimensional carotid ultrasound images. Phys Med Biol 2001; 46:1321-1342.
-
(2001)
Phys Med Biol
, vol.46
, pp. 1321-1342
-
-
Zahalka, A.1
Fenster, A.2
-
26
-
-
0030596840
-
Measurement error
-
Bland JM, Altman DG. Measurement error. BMJ 1996;313:744.
-
(1996)
BMJ
, vol.313
, pp. 744
-
-
Bland, J.M.1
Altman, D.G.2
-
27
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
28
-
-
0036136140
-
Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI
-
Steinman DA, Thomas JB, Ladak HM, Milner JS, Rutt BK, Spence JD. Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI. Magn Reson Med 2002;47:149-159.
-
(2002)
Magn Reson Med
, vol.47
, pp. 149-159
-
-
Steinman, D.A.1
Thomas, J.B.2
Ladak, H.M.3
Milner, J.S.4
Rutt, B.K.5
Spence, J.D.6
-
29
-
-
0035988854
-
Image-based computational fluid dynamics modeling in realistic arterial geometries
-
Steinman DA. Image-based computational fluid dynamics modeling in realistic arterial geometries. Ann Biomed Eng 2002;30:483-497.
-
(2002)
Ann Biomed Eng
, vol.30
, pp. 483-497
-
-
Steinman, D.A.1
-
30
-
-
0021028806
-
Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress
-
Zarins CK, Giddens DP, Bharadvaj BK, Sottiurai VS, Mabon RF, Glagov S. Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress. Circ Res 1983;53:502-514.
-
(1983)
Circ Res
, vol.53
, pp. 502-514
-
-
Zarins, C.K.1
Giddens, D.P.2
Bharadvaj, B.K.3
Sottiurai, V.S.4
Mabon, R.F.5
Glagov, S.6
-
31
-
-
0021966255
-
Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress
-
Ku DN, Giddens DP, Zarins CK, Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arteriosclerosis 1985;5:293-302.
-
(1985)
Arteriosclerosis
, vol.5
, pp. 293-302
-
-
Ku, D.N.1
Giddens, D.P.2
Zarins, C.K.3
Glagov, S.4
-
32
-
-
0023685291
-
Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries
-
Glagov S, Zarins C, Giddens DP, Ku DN. Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. Arch Pathol Lab Med 1988;112:1018-1031.
-
(1988)
Arch Pathol Lab Med
, vol.112
, pp. 1018-1031
-
-
Glagov, S.1
Zarins, C.2
Giddens, D.P.3
Ku, D.N.4
-
33
-
-
0027971558
-
Fluid wall shear stress measurements in a model of the human abdominal aorta: Oscillatory behavior and relationship to atherosclerosis
-
Moore JE Jr, Xu C, Glagov S, Zarins CK, Ku DN. Fluid wall shear stress measurements in a model of the human abdominal aorta: oscillatory behavior and relationship to atherosclerosis. Atherosclerosis 1994;110:225-240.
-
(1994)
Atherosclerosis
, vol.110
, pp. 225-240
-
-
Moore Jr, J.E.1
Xu, C.2
Glagov, S.3
Zarins, C.K.4
Ku, D.N.5
-
34
-
-
33646200963
-
Multicontrast black-blood MRI of carotid arteries: Comparison between 1.5 and 3 tesla magnetic field strengths
-
Yarnykh VL, Terashima M, Hayes CE, et al. Multicontrast black-blood MRI of carotid arteries: comparison between 1.5 and 3 tesla magnetic field strengths. J Magn Reson Imaging 2006;23:691-698.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 691-698
-
-
Yarnykh, V.L.1
Terashima, M.2
Hayes, C.E.3
-
35
-
-
33646183558
-
Multislice dark-blood carotid artery wall imaging: A 1.5 T and 3.0 T comparison
-
Koktzoglou I, Chung YC, Mani V, et al. Multislice dark-blood carotid artery wall imaging: a 1.5 T and 3.0 T comparison. J Magn Reson Imaging 2006;23:699-705.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 699-705
-
-
Koktzoglou, I.1
Chung, Y.C.2
Mani, V.3
-
36
-
-
27644516004
-
Low-grade carotid stenosis: Looking beyond the lumen with MRI
-
Wasserman BA, Wityk RJ, Trout HH 3rd, Virmani R, Low-grade carotid stenosis: looking beyond the lumen with MRI. Stroke 2005: 36:2504-2513.
-
(2005)
Stroke
, vol.36
, pp. 2504-2513
-
-
Wasserman, B.A.1
Wityk, R.J.2
Trout 3rd, H.H.3
Virmani, R.4
|