메뉴 건너뛰기




Volumn , Issue , 2006, Pages 3037-3040

Towards an automatic coronary artery segmentation algorithm

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC FRAME EXTRACTION ALGORITHMS; FAST MARCHING METHOD; VESSEL CONTOURS; X RAY FLUOROSCOPY;

EID: 34047095074     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2006.260614     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 34047123184 scopus 로고    scopus 로고
    • American Heart Association. 2005 Heart and Stroke Statistical Update, American Heart Association. Available at: http://www.americanheart.org/ downloadable/heart/1105390918119HDSStat s2005Update.pdf (Accessed April 24, 2006)
    • American Heart Association. 2005 Heart and Stroke Statistical Update, American Heart Association. Available at: http://www.americanheart.org/ downloadable/heart/1105390918119HDSStat s2005Update.pdf (Accessed April 24, 2006)
  • 2
    • 61849147989 scopus 로고    scopus 로고
    • Multi-scale Line Segmentation with Automatic Estimation of Width, Contrast and Tangential Direction in 2D and 3D Medical Images
    • Springer Verlag
    • C. Lorenz et al.: Multi-scale Line Segmentation with Automatic Estimation of Width, Contrast and Tangential Direction in 2D and 3D Medical Images. In CRVMed-MRCAS Proceedings. Springer Verlag, 1997. p. 233-242
    • (1997) CRVMed-MRCAS Proceedings , pp. 233-242
    • Lorenz, C.1
  • 4
    • 0036462551 scopus 로고    scopus 로고
    • Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction
    • Aylward, S., Bullitt, E.: Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction. IEEE Trans. Med. Imag. 21 (2002) 61-75.
    • (2002) IEEE Trans. Med. Imag , vol.21 , pp. 61-75
    • Aylward, S.1    Bullitt, E.2
  • 5
    • 0036267190 scopus 로고    scopus 로고
    • 3D MRA Coronary Axis Determination using a Minimum Cost Approach
    • O. Wink et al.: 3D MRA Coronary Axis Determination using a Minimum Cost Approach. Magnetic Resonance in Medicine 2002;47(6): 1169:1175.
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.6 , pp. 1169-1175
    • Wink, O.1
  • 6
    • 11244333369 scopus 로고    scopus 로고
    • Evaluation of Hessianbased filters to enhance the axis of coronary arteries in CT images
    • S.D. Olabarriaga, M. Breeuwer, W.J. Niessen Evaluation of Hessianbased filters to enhance the axis of coronary arteries in CT images. CARS 2003:1191-1196
    • (2003) CARS , pp. 1191-1196
    • Olabarriaga, S.D.1    Breeuwer, M.2    Niessen, W.J.3
  • 8
    • 34047116364 scopus 로고    scopus 로고
    • Available at:, Accessed April24
    • Homomorphic filtering notes. Available at: http://dehian.fmi.unisofia. bg/~blizzard/download/Image%20Processing/6.Image%20Enhancemen t%203.pdf (Accessed April24, 2006).
    • (2006) Homomorphic filtering notes
  • 10
    • 84944384748 scopus 로고    scopus 로고
    • Regularized shock filters and complex diffusion
    • Copenhagen/Denmark
    • G. Gilboa, N. Sochen, and Y. Zeevi. Regularized shock filters and complex diffusion. In Proceedings of ECCV, pages 399-413, Copenhagen/Denmark (2002).
    • (2002) Proceedings of ECCV , pp. 399-413
    • Gilboa, G.1    Sochen, N.2    Zeevi, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.