메뉴 건너뛰기




Volumn 32, Issue 4, 2007, Pages 491-496

Clinical Results of Absorbable Plates for Displaced Metacarpal Fractures

Author keywords

Absorbable implants; early functional treatment; L lactide and glycolic acid; metacarpal fracture; osteosynthesis

Indexed keywords

COPOLYMER; GLYCOLIC ACID; METAL; POLYGLACTIN; TITANIUM;

EID: 33947730549     PISSN: 03635023     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhsa.2007.02.005     Document Type: Article
Times cited : (33)

References (25)
  • 1
    • 0034999089 scopus 로고    scopus 로고
    • Operative treatment of common displaced and unstable fractures of the hand
    • Freeland A.E., Geissler W.B., and Weiss A.P. Operative treatment of common displaced and unstable fractures of the hand. J Bone Joint Surg 83A (2001) 928-945
    • (2001) J Bone Joint Surg , vol.83 A , pp. 928-945
    • Freeland, A.E.1    Geissler, W.B.2    Weiss, A.P.3
  • 2
    • 0343340046 scopus 로고    scopus 로고
    • Fixation of metacarpal fractures using absorbable hemi-cerclage sutures
    • Bruser P., Krein R., and Larkin G. Fixation of metacarpal fractures using absorbable hemi-cerclage sutures. J Hand Surg 24B (1999) 683-687
    • (1999) J Hand Surg , vol.24 B , pp. 683-687
    • Bruser, P.1    Krein, R.2    Larkin, G.3
  • 3
    • 0031180541 scopus 로고    scopus 로고
    • Possibilities and limits of intramedullary Kirschner wire osteosynthesis in treatment of metacarpal fractures
    • Larkin G., Bruser P., and Safi A. Possibilities and limits of intramedullary Kirschner wire osteosynthesis in treatment of metacarpal fractures. Handchir Mikrochir Plast Chir 29 (1997) 192-196
    • (1997) Handchir Mikrochir Plast Chir , vol.29 , pp. 192-196
    • Larkin, G.1    Bruser, P.2    Safi, A.3
  • 4
    • 0026764038 scopus 로고
    • Absorbable intramedullary implants for hand fractures. Animal experiments and clinical trial
    • Kumta S.M., Spinner R., and Leung P.C. Absorbable intramedullary implants for hand fractures. Animal experiments and clinical trial. J Bone Joint Surg 74B (1992) 563-566
    • (1992) J Bone Joint Surg , vol.74 B , pp. 563-566
    • Kumta, S.M.1    Spinner, R.2    Leung, P.C.3
  • 5
    • 0036942150 scopus 로고    scopus 로고
    • Functional bracing after operative treatment of metacarpal fractures
    • Kuntscher M., Blazek J., Bruner S., Wittemann M., and Germann G. Functional bracing after operative treatment of metacarpal fractures. Unfallchirurg 105 (2002) 1109-1114
    • (2002) Unfallchirurg , vol.105 , pp. 1109-1114
    • Kuntscher, M.1    Blazek, J.2    Bruner, S.3    Wittemann, M.4    Germann, G.5
  • 6
    • 0032463393 scopus 로고    scopus 로고
    • Complications and range of motion following plate fixation of metacarpal and phalangeal fractures
    • Page S.M., and Stern P.J. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg 23A (1998) 827-832
    • (1998) J Hand Surg , vol.23 A , pp. 827-832
    • Page, S.M.1    Stern, P.J.2
  • 7
    • 33646832030 scopus 로고    scopus 로고
    • Bioabsorbable implants in the treatment of hand fractures: an update
    • Hughes T.B. Bioabsorbable implants in the treatment of hand fractures: an update. Clin Orthop 445 (2006) 169-174
    • (2006) Clin Orthop , vol.445 , pp. 169-174
    • Hughes, T.B.1
  • 8
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Bostman O., Hirvensalo E., Makinen J., and Rokkanen P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg 72B (1990) 592-596
    • (1990) J Bone Joint Surg , vol.72 B , pp. 592-596
    • Bostman, O.1    Hirvensalo, E.2    Makinen, J.3    Rokkanen, P.4
  • 11
    • 30544446942 scopus 로고    scopus 로고
    • Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute
    • Gangopadhyay S., Ravi K., and Packer G. Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute. J Hand Surg 31B (2006) 93-100
    • (2006) J Hand Surg , vol.31 B , pp. 93-100
    • Gangopadhyay, S.1    Ravi, K.2    Packer, G.3
  • 12
    • 0036022308 scopus 로고    scopus 로고
    • Biomechanical failure of metacarpal fracture resorbable plate fixation
    • Lionelli G.T., and Korentager R.A. Biomechanical failure of metacarpal fracture resorbable plate fixation. Ann Plast Surg 49 (2002) 202-206
    • (2002) Ann Plast Surg , vol.49 , pp. 202-206
    • Lionelli, G.T.1    Korentager, R.A.2
  • 13
    • 0032977971 scopus 로고    scopus 로고
    • The DASH (Disability of Arm-Shoulder-Hand) Questionnaire-a new instrument for evaluating upper extremity treatment outcome
    • Germann G., Wind G., and Harth A. The DASH (Disability of Arm-Shoulder-Hand) Questionnaire-a new instrument for evaluating upper extremity treatment outcome. Handchir Mikrochir Plast Chir 31 (1999) 149-152
    • (1999) Handchir Mikrochir Plast Chir , vol.31 , pp. 149-152
    • Germann, G.1    Wind, G.2    Harth, A.3
  • 14
    • 0034939309 scopus 로고    scopus 로고
    • Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation
    • Bozic K.J., Perez L.E., Wilson D.R., Fitzgibbons P.G., and Jupiter J.B. Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg 26A (2001) 755-761
    • (2001) J Hand Surg , vol.26 A , pp. 755-761
    • Bozic, K.J.1    Perez, L.E.2    Wilson, D.R.3    Fitzgibbons, P.G.4    Jupiter, J.B.5
  • 15
    • 0029799096 scopus 로고    scopus 로고
    • A comparative biomechanical analysis of resorbable rigid fixation versus titanium rigid fixation of metacarpal fractures
    • Prevel C.D., Eppley B.L., Ge J., Winkler M.M., Katona T.R., D'Alessio K., et al. A comparative biomechanical analysis of resorbable rigid fixation versus titanium rigid fixation of metacarpal fractures. Ann Plast Surg 37 (1996) 377-385
    • (1996) Ann Plast Surg , vol.37 , pp. 377-385
    • Prevel, C.D.1    Eppley, B.L.2    Ge, J.3    Winkler, M.M.4    Katona, T.R.5    D'Alessio, K.6
  • 16
    • 0036738361 scopus 로고    scopus 로고
    • Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study
    • Waris E., Ashammakhi N., Raatikainen T., Tormala P., Santavirta S., and Konttinen Y.T. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg 27A (2002) 902-909
    • (2002) J Hand Surg , vol.27 A , pp. 902-909
    • Waris, E.1    Ashammakhi, N.2    Raatikainen, T.3    Tormala, P.4    Santavirta, S.5    Konttinen, Y.T.6
  • 18
    • 33947723800 scopus 로고    scopus 로고
    • Schleikis A. Obere Extremität. In: Gips und Synthetischer Stützverband. Steinkopf Verlag, XIV Darmstadt, 2000;24-89.
  • 19
    • 0025961327 scopus 로고
    • Ultra-high-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: in vitro and in vivo study
    • Tormala P., Vasenius J., Vainionpaa S., Laiho J., Pohjonen T., and Rokkanen P. Ultra-high-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: in vitro and in vivo study. J Biomed Mater Res 25 (1991) 1-22
    • (1991) J Biomed Mater Res , vol.25 , pp. 1-22
    • Tormala, P.1    Vasenius, J.2    Vainionpaa, S.3    Laiho, J.4    Pohjonen, T.5    Rokkanen, P.6
  • 20
    • 0742288129 scopus 로고    scopus 로고
    • Successful treatment of scaphoid fractures and nonunions using bioabsorbable screws: report of six cases
    • Kujala S., Raatikainen T., Kaarela O., Ashammakhi N., and Ryhanen J. Successful treatment of scaphoid fractures and nonunions using bioabsorbable screws: report of six cases. J Hand Surg 29A (2004) 68-73
    • (2004) J Hand Surg , vol.29 A , pp. 68-73
    • Kujala, S.1    Raatikainen, T.2    Kaarela, O.3    Ashammakhi, N.4    Ryhanen, J.5
  • 21
    • 2442700301 scopus 로고    scopus 로고
    • Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports
    • Waris E., Ninkovic M., Harpf C., Ninkovic M., and Ashammakhi N. Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports. J Hand Surg 29A (2004) 452-457
    • (2004) J Hand Surg , vol.29 A , pp. 452-457
    • Waris, E.1    Ninkovic, M.2    Harpf, C.3    Ninkovic, M.4    Ashammakhi, N.5
  • 22
    • 0029891715 scopus 로고    scopus 로고
    • Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep
    • Weiler A., Helling H.J., Kirch U., Zirbes T.K., and Rehm K.E. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. J Bone Joint Surg 78B (1996) 369-376
    • (1996) J Bone Joint Surg , vol.78 B , pp. 369-376
    • Weiler, A.1    Helling, H.J.2    Kirch, U.3    Zirbes, T.K.4    Rehm, K.E.5
  • 23
    • 0028878553 scopus 로고
    • Late degradation tissue response to poly(L-lactide) bone plates and screws
    • Bergsma J.E., de Bruijn W.C., Rozema F.R., Bos R.R., and Boering G. Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials 16 (1995) 25-31
    • (1995) Biomaterials , vol.16 , pp. 25-31
    • Bergsma, J.E.1    de Bruijn, W.C.2    Rozema, F.R.3    Bos, R.R.4    Boering, G.5
  • 24
    • 1442326752 scopus 로고    scopus 로고
    • Refixation of osteochondral fragments using absorbable implants. First results of a retrospective study
    • Fuchs M., Vosshenrich R., Dumont C., and Sturmer K.M. Refixation of osteochondral fragments using absorbable implants. First results of a retrospective study. Chirurg 74 (2003) 554-561
    • (2003) Chirurg , vol.74 , pp. 554-561
    • Fuchs, M.1    Vosshenrich, R.2    Dumont, C.3    Sturmer, K.M.4
  • 25
    • 0030926022 scopus 로고    scopus 로고
    • Resorbable plate fixation in pediatric craniofacial surgery
    • Eppley B.L., Sadove A.M., and Havlik R.J. Resorbable plate fixation in pediatric craniofacial surgery. Plast Reconstr Surg 100 (1997) 1-13
    • (1997) Plast Reconstr Surg , vol.100 , pp. 1-13
    • Eppley, B.L.1    Sadove, A.M.2    Havlik, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.