메뉴 건너뛰기




Volumn 123, Issue 1, 2007, Pages 560-567

Simulation of QCM sensors based on high stability classical oscillator configurations in damping media

Author keywords

Damping media; High stability classical electronic oscillator; Quartz crystal microbalance; Simulation

Indexed keywords

ALGORITHMS; COMPUTATIONAL COMPLEXITY; COMPUTER SIMULATION; DAMPING; OSCILLATORS (ELECTRONIC);

EID: 33947697701     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.09.061     Document Type: Article
Times cited : (5)

References (28)
  • 1
    • 14744287343 scopus 로고    scopus 로고
    • Resolution in quartz crystal oscillator circuits for high sensitivity microbalance sensors in damping media
    • Rodriguez-Pardo L., Fariña J., Gabrielli C., Perrot H., and Brendel R. Resolution in quartz crystal oscillator circuits for high sensitivity microbalance sensors in damping media. Sens. Actuators, B 103 (2004) 318-324
    • (2004) Sens. Actuators, B , vol.103 , pp. 318-324
    • Rodriguez-Pardo, L.1    Fariña, J.2    Gabrielli, C.3    Perrot, H.4    Brendel, R.5
  • 3
    • 0034877133 scopus 로고    scopus 로고
    • Biotinylated polypyrrole modified quartz crystal microbalance for rapid and reagentless determination of avidin concentration
    • Cosnier S., Perrot H., and Wessel R. Biotinylated polypyrrole modified quartz crystal microbalance for rapid and reagentless determination of avidin concentration. Electroanalysis 13 (2001) 971-973
    • (2001) Electroanalysis , vol.13 , pp. 971-973
    • Cosnier, S.1    Perrot, H.2    Wessel, R.3
  • 4
    • 0032728330 scopus 로고    scopus 로고
    • Biosensors based on piezoelectric transducers
    • Bizet K., Gabrielli C., and Perrot H. Biosensors based on piezoelectric transducers. Analusis Eur. JAC 7 (1999) 609-616
    • (1999) Analusis Eur. JAC , vol.7 , pp. 609-616
    • Bizet, K.1    Gabrielli, C.2    Perrot, H.3
  • 6
    • 84951279351 scopus 로고
    • Verwendung von schwingquarzen zur wägung dünner schichten und zur mikrowägung
    • Sauerbrey G. Verwendung von schwingquarzen zur wägung dünner schichten und zur mikrowägung. Zeitschrift Fuer Physik 155 (1959) 206-222
    • (1959) Zeitschrift Fuer Physik , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 7
    • 0035437737 scopus 로고    scopus 로고
    • An extended Butterworth-Van Dyke model for quartz crystal microbalance applications in viscoelastic fluid media
    • Arnau A., Jimenez Y., and Sorogob T. An extended Butterworth-Van Dyke model for quartz crystal microbalance applications in viscoelastic fluid media. IEEE Trans. UFFC 48 5 (2001) 1367-1384
    • (2001) IEEE Trans. UFFC , vol.48 , Issue.5 , pp. 1367-1384
    • Arnau, A.1    Jimenez, Y.2    Sorogob, T.3
  • 8
    • 36449008243 scopus 로고
    • Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers
    • Granstaff V.E., and Martin S.J. Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers. J. Appl. Phys. 75 3 (1994) 1319-1329
    • (1994) J. Appl. Phys. , vol.75 , Issue.3 , pp. 1319-1329
    • Granstaff, V.E.1    Martin, S.J.2
  • 10
    • 33947704520 scopus 로고    scopus 로고
    • T. Blin, Méthodologie de Modélisation des Oscillateurs à Quartz: Application aux Oscillateurs Ultra-Stables pour Applications Spatiales, Thèse Sciences pour l'Ingénieur, UFR des Sciences et Techniques, Université de Franche-Compté, Décembre 1995.
  • 11
    • 33947672744 scopus 로고
    • Quartz crystal oscillators from their design to their performances
    • Gagnepain J.J. Quartz crystal oscillators from their design to their performances. Proc. 4th EFTF (1990) 121-129
    • (1990) Proc. 4th EFTF , pp. 121-129
    • Gagnepain, J.J.1
  • 12
    • 0016867071 scopus 로고
    • Computer design and analysis for high precision oscillator
    • Nardin R., and Ho J. Computer design and analysis for high precision oscillator. Proc. 28th AFCS (1974) 237-242
    • (1974) Proc. 28th AFCS , pp. 237-242
    • Nardin, R.1    Ho, J.2
  • 13
    • 0016866741 scopus 로고
    • New approach to the design of crystal oscillators
    • Ohata Y. New approach to the design of crystal oscillators. Proc. 28th AFCS (1974) 221-231
    • (1974) Proc. 28th AFCS , pp. 221-231
    • Ohata, Y.1
  • 14
    • 33947617151 scopus 로고
    • Universal, computer facilitated, steady state oscillator, closed loop analysis theory Borne applications to precision crystal oscillators
    • Parzen B. Universal, computer facilitated, steady state oscillator, closed loop analysis theory Borne applications to precision crystal oscillators. IEEE Freq. Control Symp. (1992) 453-464
    • (1992) IEEE Freq. Control Symp. , pp. 453-464
    • Parzen, B.1
  • 15
    • 0023566552 scopus 로고
    • The design and analysis of VHF/UHF crystal oscillators
    • Benjaminson A. The design and analysis of VHF/UHF crystal oscillators. 41st Annu. Freq. Control Symp. (1987) 452-459
    • (1987) 41st Annu. Freq. Control Symp. , pp. 452-459
    • Benjaminson, A.1
  • 16
    • 0022288526 scopus 로고
    • Computer analysis of Colpitts crystal oscillator
    • Adachi T., Hirose M., and Tsuzuki Y. Computer analysis of Colpitts crystal oscillator. Proc. 39th AFCS (1985) 176-182
    • (1985) Proc. 39th AFCS , pp. 176-182
    • Adachi, T.1    Hirose, M.2    Tsuzuki, Y.3
  • 17
    • 0024027810 scopus 로고
    • A simple way of characterizing high Q oscillators
    • Goldberg J. A simple way of characterizing high Q oscillators. Proc. 42nd AFCS (1988) 304-326
    • (1988) Proc. 42nd AFCS , pp. 304-326
    • Goldberg, J.1
  • 20
    • 33947673774 scopus 로고    scopus 로고
    • Publication and Proposed Revision of IEEE Standard 177-1966, Standard Definitions and Methods of Measurement for Piezoelectric Vibrators, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 40, no. 1, pp. 1-20, January 1993.
  • 21
    • 0034449186 scopus 로고    scopus 로고
    • J.R.Vig, F.L. Walls, A Review of Sensor Sensitivity and Stability, Proceedings of 2000 IEEE/EIA International Frequency Control Symposium and Exhibition, pp. 30-33.
  • 23
    • 0035483110 scopus 로고    scopus 로고
    • Improving the accuracy and operating range of quartz microbalance sensors by a purposely designed oscillator circuit
    • Ferrari V., Marioli D., and Taroni A. Improving the accuracy and operating range of quartz microbalance sensors by a purposely designed oscillator circuit. IEEE Trans. Instrum. Meas. 50 5 (2001) 1119-1122
    • (2001) IEEE Trans. Instrum. Meas. , vol.50 , Issue.5 , pp. 1119-1122
    • Ferrari, V.1    Marioli, D.2    Taroni, A.3
  • 24
    • 0036640343 scopus 로고    scopus 로고
    • Circuit for continuous motional series resonant frequency and motional resistance monitoring of quartz crystal resonators by parallel capacitance compensation
    • Arnau A., Sorogob T., and Jimenez Y. Circuit for continuous motional series resonant frequency and motional resistance monitoring of quartz crystal resonators by parallel capacitance compensation. Rev. Sci. Instrum. 73 7 (2002)
    • (2002) Rev. Sci. Instrum. , vol.73 , Issue.7
    • Arnau, A.1    Sorogob, T.2    Jimenez, Y.3
  • 26
    • 0008643341 scopus 로고    scopus 로고
    • EQCM corrosion sensor for solid metals and metal alloys. Application to the dissolution of 304 stainless steel
    • Ehahoun H., Gabrielli C., Keddam M., Perrot H., Cetre Y., and Diguet L. EQCM corrosion sensor for solid metals and metal alloys. Application to the dissolution of 304 stainless steel. J. Electrochem. Soc. 148 (2001) B333-B336
    • (2001) J. Electrochem. Soc. , vol.148
    • Ehahoun, H.1    Gabrielli, C.2    Keddam, M.3    Perrot, H.4    Cetre, Y.5    Diguet, L.6
  • 28
    • 33947676206 scopus 로고    scopus 로고
    • L. Rodriguez-Pardo, J. Fariña, C. Gabrielli, H. Perrot, R. Brendel, Design considerations of Miller oscillators for high sensitivity QCM sensors in damping media, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, in press.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.