메뉴 건너뛰기




Volumn 73, Issue 4, 2007, Pages 369-374

A rigorous laboratory calibration method for interior orientation of an airborne linear push-broom camera

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; CHARGE COUPLED DEVICES; IMAGE PROCESSING; IMAGING SYSTEMS; PHOTOGRAMMETRY; REMOTE SENSING;

EID: 33947662948     PISSN: 00991112     EISSN: None     Source Type: Journal    
DOI: 10.14358/PERS.73.4.369     Document Type: Review
Times cited : (24)

References (16)
  • 4
    • 0037229492 scopus 로고    scopus 로고
    • Development and calibration of the airborne three-line Scanner (TLS) imaging system
    • Chen, T., R. Shibasaki, and M. Shunji, 2003. Development and calibration of the airborne three-line Scanner (TLS) imaging system, Photogrammetric Engineering & Remote Sensing, 69(1):71-78.
    • (2003) Photogrammetric Engineering & Remote Sensing , vol.69 , Issue.1 , pp. 71-78
    • Chen, T.1    Shibasaki, R.2    Shunji, M.3
  • 5
    • 85036703031 scopus 로고    scopus 로고
    • Performance of the imaging system in the LH Systems ADS40 airborne digital sensor
    • Amsterdam, pp
    • Eckardt, A., B. Braunecker, and R. Sandau, 2000. Performance of the imaging system in the LH Systems ADS40 airborne digital sensor. International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B2, Amsterdam, pp. 104-109.
    • (2000) International Archives of Photogrammetry and Remote Sensing , vol.33 , Issue.PART B2 , pp. 104-109
    • Eckardt, A.1    Braunecker, B.2    Sandau, R.3
  • 6
    • 84957090805 scopus 로고    scopus 로고
    • Rigorous photogrammetric processing of high resolution satellite imagery
    • Amsterdam, pp
    • Fritschm, D., and D. Stallmann, 2000. Rigorous photogrammetric processing of high resolution satellite imagery, International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B1, Amsterdam, pp. 313-321.
    • (2000) International Archives of Photogrammetry and Remote Sensing , vol.33 , Issue.PART B1 , pp. 313-321
    • Fritschm, D.1    Stallmann, D.2
  • 7
    • 0002458974 scopus 로고
    • Camera calibration in non-topographic photogrammetry
    • 2nd edition, American Society for Photogrammetry and Remote Sensing, Falls Church, Virginia, pp
    • nd edition, American Society for Photogrammetry and Remote Sensing, Falls Church, Virginia, pp. 59-70.
    • (1989) Non-topographic Photogrammetry , pp. 59-70
    • Fryer, J.G.1
  • 9
    • 84858317101 scopus 로고    scopus 로고
    • Gruen, A., and L. Zhang, 2002. Automatic DTM generation from three-line-scanner (TLS) images, International Archives of Photogrammetry and Remote Sensing, 34, Part 2A, Graz, Austria, pp. 131-137.
    • Gruen, A., and L. Zhang, 2002. Automatic DTM generation from three-line-scanner (TLS) images, International Archives of Photogrammetry and Remote Sensing, Vol. 34, Part 2A, Graz, Austria, pp. 131-137.
  • 11
    • 0002916838 scopus 로고    scopus 로고
    • Design concepts for digital photogrammetric cameras
    • D. Fritsch and D. Hobbie, editors, Wichmann, Heidelberg
    • Hinz, A., 1997. Design concepts for digital photogrammetric cameras, Proceedings of Photogrammetric Week '97 (D. Fritsch and D. Hobbie, editors), Wichmann, Heidelberg.
    • (1997) Proceedings of Photogrammetric Week '97
    • Hinz, A.1