메뉴 건너뛰기




Volumn 62, Issue 4, 2007, Pages 364-373

Temporary epicardial pacing after cardiac surgery: A practical review: Part 2: Selection of epicardial pacing modes and troubleshooting

Author keywords

[No Author keywords available]

Indexed keywords

ATRIOVENTRICULAR BLOCK; BRADYCARDIA; ELECTROCARDIOGRAM; EQUIPMENT DESIGN; HEART ATRIOVENTRICULAR NODE; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART DEPOLARIZATION; HEART HEMODYNAMICS; HEART OUTPUT; HEART PACING; HEART REPOLARIZATION; HEART SURGERY; HEART VENTRICLE FIBRILLATION; HUMAN; INTENSIVE CARE; INTERMETHOD COMPARISON; REVIEW; SINUS RHYTHM; SPIKE WAVE; SUPRAVENTRICULAR TACHYCARDIA; TACHYCARDIA; TREATMENT CONTRAINDICATION; TREATMENT FAILURE; TREATMENT INDICATION;

EID: 33947643602     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2007.04951.x     Document Type: Review
Times cited : (30)

References (11)
  • 2
    • 0024619565 scopus 로고
    • Temporary epicardial pacing after open heart surgery: Complications and prevention
    • Del Nido P, Goldman BS. Temporary epicardial pacing after open heart surgery: Complications and prevention. Journal of Cardiac Surgery 1989; 4: 99-103.
    • (1989) Journal of Cardiac Surgery , vol.4 , pp. 99-103
    • Del Nido, P.1    Goldman, B.S.2
  • 3
    • 0036188987 scopus 로고    scopus 로고
    • The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing
    • North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group
    • Bernstein AD, Daubert JC, Fletcher RD, et al. The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing. North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group. Pacing and Clinical Electrophysiology 2002; 25: 260-4.
    • (2002) Pacing and Clinical Electrophysiology , vol.25 , pp. 260-264
    • Bernstein, A.D.1    Daubert, J.C.2    Fletcher, R.D.3
  • 4
    • 33747126408 scopus 로고    scopus 로고
    • Pacemakers and implantable cardioverter defibrillators
    • Allen M. Pacemakers and implantable cardioverter defibrillators. Anaesthesia 2006; 61: 883-90.
    • (2006) Anaesthesia , vol.61 , pp. 883-890
    • Allen, M.1
  • 5
    • 33750312868 scopus 로고    scopus 로고
    • Cardiac pacing and defibrillation
    • In: Kaplan JA, Reich DL, Lake CL, Konstadt SN, eds. Philadelphia: W. B. Saunders
    • Rozner MA, Trankina M. Cardiac pacing and defibrillation. In: Kaplan JA, Reich DL, Lake CL, Konstadt SN, eds. Kaplan's Cardiac Anesthesia. Philadelphia: W. B. Saunders, 2006; 827-43.
    • (2006) Kaplan's Cardiac Anesthesia , pp. 827-843
    • Rozner, M.A.1    Trankina, M.2
  • 8
    • 0032947976 scopus 로고    scopus 로고
    • Electromagnetic interference of external pacemakers by walkie-talkies and digital cellular phones: Experimental study
    • Trigano AJ, Azoulay A, Rochdi M, Campillo A. Electromagnetic interference of external pacemakers by walkie-talkies and digital cellular phones: Experimental study. Pacing and Clinical Electrophysiology 1999; 22: 588-93.
    • (1999) Pacing and Clinical Electrophysiology , vol.22 , pp. 588-593
    • Trigano, A.J.1    Azoulay, A.2    Rochdi, M.3    Campillo, A.4
  • 9
    • 0035205680 scopus 로고    scopus 로고
    • Cardiac rhythm management devices (Part II): Perioperative management
    • Atlee JL, Bernstein AD. Cardiac rhythm management devices (Part II): perioperative management. Anesthesiology 2001; 95: 1492-506.
    • (2001) Anesthesiology , vol.95 , pp. 1492-1506
    • Atlee, J.L.1    Bernstein, A.D.2
  • 10
    • 0027178279 scopus 로고
    • Optimal atrioventricular (AV) pacing interval during temporary AV sequential pacing after cardiac surgery
    • Durbin CG Jr, Kopel RF. Optimal atrioventricular (AV) pacing interval during temporary AV sequential pacing after cardiac surgery. Journal of Cardiothoracic and Vascular Anesthesia 1993; 7: 316-20.
    • (1993) Journal of Cardiothoracic and Vascular Anesthesia , vol.7 , pp. 316-320
    • Durbin Jr., C.G.1    Kopel, R.F.2
  • 11
    • 0033836483 scopus 로고    scopus 로고
    • The strength-duration curve and its importance in pacing efficiency: A study of 325 pacing leads in 229 patients
    • Coates S, Thwaites B. The strength-duration curve and its importance in pacing efficiency: A study of 325 pacing leads in 229 patients. Pacing and Clinical Electrophysiology 2000; 23: 1273-7.
    • (2000) Pacing and Clinical Electrophysiology , vol.23 , pp. 1273-1277
    • Coates, S.1    Thwaites, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.