메뉴 건너뛰기




Volumn 7, Issue , 2007, Pages

Radiation dose reduction at a price: The effectiveness of a male gonadal shield during helical CT scans

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CHILD HEALTH CARE; GONAD; IMAGE ANALYSIS; IMAGE QUALITY; IONIZATION CHAMBER; MALE GENITAL SYSTEM; RADIATION BEAM; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RADIATION SCATTERING; RADIATION SHIELD; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; ABDOMINAL RADIOGRAPHY; ADULT; ANTIBODY SPECIFICITY; BODY BURDEN; COMPUTER ASSISTED DIAGNOSIS; DEVICES; HUMAN; MALE; PROCEDURES; RADIATION PROTECTION; RADIOMETRY; RELATIVE BIOLOGIC EFFECTIVENESS; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TESTIS;

EID: 33947621537     PISSN: None     EISSN: 14712342     Source Type: Journal    
DOI: 10.1186/1471-2342-7-5     Document Type: Article
Times cited : (34)

References (28)
  • 1
    • 0034529475 scopus 로고    scopus 로고
    • CT scanning: Patterns of use and dose
    • 10.1088/0952-4746/20/4/301 11140709
    • Mettler FA Jr. Wiest PW Locken JA Kelsey CA CT scanning: Patterns of use and dose J Radiol Prot 2000 20 4 353-359 10.1088/0952-4746/20/4/301 11140709
    • (2000) J Radiol Prot , vol.20 , Issue.4 , pp. 353-359
    • Mettler Jr., F.A.1    Wiest, P.W.2    Locken, J.A.3    Kelsey, C.A.4
  • 2
    • 0012187967 scopus 로고    scopus 로고
    • Trends in Diagnostic Imaging to 2000
    • London, Financial Times, Pharmaceuticals and Healthcare Publishing
    • Bahador B Trends in Diagnostic Imaging to 2000 London, Financial Times, Pharmaceuticals and Healthcare Publishing 1996
    • (1996) Financial Times
    • Bahador, B.1
  • 3
    • 0021848044 scopus 로고
    • National CT use and radiation exposure: United States 1983
    • 3872566
    • Evens RG Mettler FA National CT use and radiation exposure: United States 1983 Ajr 1985 144 5 1077-1081 3872566
    • (1985) Ajr , vol.144 , Issue.5 , pp. 1077-1081
    • Evens, R.G.1    Mettler, F.A.2
  • 4
    • 33947617163 scopus 로고    scopus 로고
    • Soaring CT use may prompt need for long-term dose monitoring
    • DiagnosticImagingcom August
    • Hayes J Soaring CT use may prompt need for long-term dose monitoring. August. DiagnosticImagingcom 2006
    • (2006)
    • Hayes, J.1
  • 5
    • 0036938688 scopus 로고    scopus 로고
    • Current adult and pediatric CT doses
    • 10.1007/s00247-002-0677-8 11956706
    • Nickoloff E Current adult and pediatric CT doses Pediatric radiology 2002 32 4 250-260 10.1007/s00247-002-0677-8 11956706
    • (2002) Pediatric Radiology , vol.32 , Issue.4 , pp. 250-260
    • Nickoloff, E.1
  • 6
    • 0036934963 scopus 로고    scopus 로고
    • Effective doses to adult and pediatric patients
    • 10.1007/s00247-002-0680-0 11956709
    • Huda W Effective doses to adult and pediatric patients Pediatric radiology 2002 32 4 272-279 10.1007/s00247-002-0680-0 11956709
    • (2002) Pediatric Radiology , vol.32 , Issue.4 , pp. 272-279
    • Huda, W.1
  • 8
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • 11159059
    • Brenner D Elliston C Hall E Berdon W Estimated risks of radiation-induced fatal cancer from pediatric CT Ajr 2001 176 2 289-296 11159059
    • (2001) Ajr , vol.176 , Issue.2 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 9
    • 33746585338 scopus 로고    scopus 로고
    • American Academy of Pediatrics clinical report: Radiation risk to children from CT imaging
    • (in press)
    • Brody A D. F Huda W American Academy of Pediatrics clinical report: radiation risk to children from CT imaging. Pediatrics 2006 (in press)
    • (2006) Pediatrics
    • Brody, A.D.F.1    Huda, W.2
  • 10
    • 33746623997 scopus 로고    scopus 로고
    • Conventional and CT angiography in children: Dosimetry and dose comparisons
    • 10.1007/s00247-006-0190-6
    • Frush DP Yoshizumi T Conventional and CT angiography in children: dosimetry and dose comparisons Pediatric radiology 2006 36 Supplement 14 154-158 10.1007/s00247-006-0190-6
    • (2006) Pediatric Radiology , vol.36 , Issue.SUPPL. 14 , pp. 154-158
    • Frush, D.P.1    Yoshizumi, T.2
  • 11
    • 1642304438 scopus 로고    scopus 로고
    • Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients
    • 15039151
    • Cody DD Moxley DM Krugh KT O'Daniel JC Wagner LK Eftekhari F Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients Ajr 2004 182 4 849-859 15039151
    • (2004) Ajr , vol.182 , Issue.4 , pp. 849-859
    • Cody, D.D.1    Moxley, D.M.2    Krugh, K.T.3    O'Daniel, J.C.4    Wagner, L.K.5    Eftekhari, F.6
  • 12
    • 26044445862 scopus 로고    scopus 로고
    • Patient-circumference-adapted dose regulation in body computed tomography. A practical and flexible formula
    • 10.1080/02841850510021193 16134317
    • Nyman U Ahl TL Kristiansson M Nilsson L Wettemark S Patient-circumference-adapted dose regulation in body computed tomography. A practical and flexible formula Acta Radiol 2005 46 4 396-406 10.1080/02841850510021193 16134317
    • (2005) Acta Radiol , vol.46 , Issue.4 , pp. 396-406
    • Nyman, U.1    Ahl, T.L.2    Kristiansson, M.3    Nilsson, L.4    Wettemark, S.5
  • 13
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    • 15358847
    • Siegel MJ Schmidt B Bradley D Suess C Hildebolt C Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape Radiology 2004 233 2 515-522 15358847
    • (2004) Radiology , vol.233 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 14
    • 0032870230 scopus 로고    scopus 로고
    • Radiation dose reduction in paediatric cranial CT
    • 10.1007/s002470050692 10525786
    • Chan CY Wong YC Chau LF Yu SK Lau PC Radiation dose reduction in paediatric cranial CT Pediatric radiology 1999 29 10 770-775 10.1007/ s002470050692 10525786
    • (1999) Pediatric Radiology , vol.29 , Issue.10 , pp. 770-775
    • Chan, C.Y.1    Wong, Y.C.2    Chau, L.F.3    Yu, S.K.4    Lau, P.C.5
  • 15
    • 33947659850 scopus 로고
    • New York, Pergamon Press ICRP 1990 Recommendations of the ICRP: International Commission on Radiological Protection Publication 60
    • ICRP 1990 Recommendations of the ICRP: International Commission on Radiological Protection Publication 60 New York, Pergamon Press 1990
    • (1990)
  • 16
    • 33947672254 scopus 로고    scopus 로고
    • ICRP Draft Recommendations of the International Commission on Radiological Protection 02/276/06 2006
    • ICRP Draft Recommendations of the International Commission on Radiological Protection 02/276/06 2006
    • (2006)
  • 17
    • 0018747754 scopus 로고
    • Development of a radiographic chest phantom with disease simulation
    • 10.1097/00004424-197903000-00013 478808
    • Pearce JG Milne EN Gillan GD Roeck WW Development of a radiographic chest phantom with disease simulation Investigative radiology 1979 14 2 181-184 10.1097/00004424-197903000-00013 478808
    • (1979) Investigative Radiology , vol.14 , Issue.2 , pp. 181-184
    • Pearce, J.G.1    Milne, E.N.2    Gillan, G.D.3    Roeck, W.W.4
  • 18
    • 0025367219 scopus 로고
    • A patient-equivalent attenuation phantom for estimating patient exposures from automatic exposure controlled x-ray examinations of the abdomen and lumbo-sacral spine
    • 10.1118/1.596483 2385202
    • Conway BJ Duff JE Fewell TR Jennings RJ Rothenberg LN Fleischman RC A patient-equivalent attenuation phantom for estimating patient exposures from automatic exposure controlled x-ray examinations of the abdomen and lumbo-sacral spine Medical physics 1990 17 3 448-453 10.1118/1.596483 2385202
    • (1990) Medical Physics , vol.17 , Issue.3 , pp. 448-453
    • Conway, B.J.1    Duff, J.E.2    Fewell, T.R.3    Jennings, R.J.4    Rothenberg, L.N.5    Fleischman, R.C.6
  • 19
    • 0003868944 scopus 로고
    • The physics of radiology
    • Springfield, Ill, Charles C Thomas 4
    • Johns HE Cunningham JR The physics of radiology Springfield, Ill, Charles C Thomas 4 1983
    • (1983)
    • Johns, H.E.1    Cunningham, J.R.2
  • 20
    • 0033011952 scopus 로고    scopus 로고
    • Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield
    • 10505015
    • Price R Halson P Sampson M Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield The British journal of radiology 1999 72 857 489-494 10505015
    • (1999) The British Journal of Radiology , vol.72 , Issue.857 , pp. 489-494
    • Price, R.1    Halson, P.2    Sampson, M.3
  • 21
    • 0029906105 scopus 로고    scopus 로고
    • The efficacy of lead shielding in patient dosage reduction in computed tomography
    • Hidajat N Schroder RJ Vogl T Schedel H Felix R [The efficacy of lead shielding in patient dosage reduction in computed tomography] Rofo 1996 165 5 462-465 8998318
    • (1996) Rofo , vol.165 , Issue.5 , pp. 462-465
    • Hidajat, N.1    Schroder, R.J.2    Vogl, T.3    Schedel, H.4    Felix, R.5
  • 22
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • 10.1148/rg.246045065 15537976 15537976
    • Barrett JF Keat N Artifacts in CT: Recognition and avoidance Radiographics 2004 24 6 1679-1691 10.1148/rg.246045065 15537976
    • (2004) Radiographics , vol.24 , Issue.6 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 23
    • 0033819209 scopus 로고    scopus 로고
    • Shielding reproductive organs of orthopaedic patients during pelvic radiography
    • 11041029
    • Wainwright AM Shielding reproductive organs of orthopaedic patients during pelvic radiography Annals of the Royal College of Surgeons of England 2000 82 5 318-321 11041029
    • (2000) Annals of the Royal College of Surgeons of England , vol.82 , Issue.5 , pp. 318-321
    • Wainwright, A.M.1
  • 24
    • 0026591357 scopus 로고
    • Gonad protection in young orthopaedic patients
    • (Clinical research ed 1628015
    • Kenny N Hill J Gonad protection in young orthopaedic patients BMJ (Clinical research ed 1992 304 6839 1411-1413 1628015
    • (1992) BMJ , vol.304 , Issue.6839 , pp. 1411-1413
    • Kenny, N.1    Hill, J.2
  • 25
    • 0242551419 scopus 로고    scopus 로고
    • Study on the use of gonadal protection shields during paediatric pelvic X-rays
    • 10.1308/003588403322520852 14629889
    • Sikand M Stinchcombe S Livesley PJ Study on the use of gonadal protection shields during paediatric pelvic X-rays Annals of the Royal College of Surgeons of England 2003 85 6 422-425 10.1308/ 003588403322520852 14629889
    • (2003) Annals of the Royal College of Surgeons of England , vol.85 , Issue.6 , pp. 422-425
    • Sikand, M.1    Stinchcombe, S.2    Livesley, P.J.3
  • 26
    • 33748454831 scopus 로고    scopus 로고
    • Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    • 10.1007/s00330-006-0217-2 16604323
    • Geleijns J Salvado Artells M Veldkamp WJ Lopez Tortosa M Calzado Cantera A Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality European radiology 2006 16 10 2334-2340 10.1007/ s00330-006-0217-2 16604323
    • (2006) European Radiology , vol.16 , Issue.10 , pp. 2334-2340
    • Geleijns, J.1    Salvado Artells, M.2    Veldkamp, W.J.3    Lopez Tortosa, M.4    Calzado Cantera, A.5
  • 27
    • 33947645240 scopus 로고    scopus 로고
    • Radiation & pediatric computed tomography: A guide for health care providers from the National Cancer Insitute and The Society for Pediatric Radiology
    • Rockville, MD, National Cancer Institute
    • NCI Radiation & pediatric computed tomography: A guide for health care providers from the National Cancer Insitute and The Society for Pediatric Radiology. Rockville, MD, National Cancer Institute 2002
    • (2002)
  • 28
    • 0008719412 scopus 로고    scopus 로고
    • FDA public health notification: Reducing radiation risk from computed tomography for pediatric and small adult patients
    • Washington D.C., U.S. Food and Drug Administration Center for Devices and Radiological Health
    • FDA FDA public health notification: Reducing radiation risk from computed tomography for pediatric and small adult patients. Washington D.C., U.S. Food and Drug Administration Center for Devices and Radiological Health 2001
    • (2001)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.