메뉴 건너뛰기




Volumn 67, Issue 5, 2007, Pages 1484-1491

Improved Dose Targeting for a Clinical Epithermal Neutron Capture Beam Using Optional 6Li Filtration

Author keywords

Boron neutron capture therapy; Brain irradiation; Epithermal neutrons; Neutron filter

Indexed keywords

COMPUTER SIMULATION; DOSIMETRY; MONTE CARLO METHODS; NEUTRON BEAMS; TISSUE; TUMORS;

EID: 33947542969     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2006.11.022     Document Type: Article
Times cited : (13)

References (30)
  • 1
    • 4444357127 scopus 로고    scopus 로고
    • A state-of-the-art epithermal neutron irradiation facility for neutron capture therapy
    • Riley K.J., Binns P.J., and Harling O.K. A state-of-the-art epithermal neutron irradiation facility for neutron capture therapy. Phys Med Biol 49 (2004) 3725-3735
    • (2004) Phys Med Biol , vol.49 , pp. 3725-3735
    • Riley, K.J.1    Binns, P.J.2    Harling, O.K.3
  • 2
    • 0000323139 scopus 로고    scopus 로고
    • The chemistry of neutron capture therapy
    • Solaway A.H., Tjarks W., Barnum D.A., et al. The chemistry of neutron capture therapy. Chem Rev 98 (1998) 1515-1562
    • (1998) Chem Rev , vol.98 , pp. 1515-1562
    • Solaway, A.H.1    Tjarks, W.2    Barnum, D.A.3
  • 3
    • 0036496482 scopus 로고    scopus 로고
    • The fission converter-based epithermal neutron irradiation facility at the Massachusetts Institute of Technology Reactor
    • Harling O.K., Riley K.J., Newton T.H., et al. The fission converter-based epithermal neutron irradiation facility at the Massachusetts Institute of Technology Reactor. Nucl Sci Eng 140 (2002) 223-240
    • (2002) Nucl Sci Eng , vol.140 , pp. 223-240
    • Harling, O.K.1    Riley, K.J.2    Newton, T.H.3
  • 4
    • 0037425306 scopus 로고    scopus 로고
    • Performance characteristics of the MIT fission converter based epithermal neutron beam
    • Riley K.J., Binns P.J., and Harling O.K. Performance characteristics of the MIT fission converter based epithermal neutron beam. Phys Med Biol 48 (2003) 943-958
    • (2003) Phys Med Biol , vol.48 , pp. 943-958
    • Riley, K.J.1    Binns, P.J.2    Harling, O.K.3
  • 5
    • 0036680149 scopus 로고    scopus 로고
    • Treatment planning and dosimetry for the Harvard-MIT phase I clinical trial of cranial neutron capture therapy
    • Palmer M.R., Goorley J.T., Kiger III W.S., et al. Treatment planning and dosimetry for the Harvard-MIT phase I clinical trial of cranial neutron capture therapy. Int J Radiat Oncol Biol Phys 53 (2002) 1361-1379
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1361-1379
    • Palmer, M.R.1    Goorley, J.T.2    Kiger III, W.S.3
  • 6
    • 4143110298 scopus 로고    scopus 로고
    • Preliminary treatment planning and dosimetry for a clinical trial of neutron capture therapy using a fission converter epithermal neutron beam
    • Kiger III W.S., Lu X.Q., Harling O.K., et al. Preliminary treatment planning and dosimetry for a clinical trial of neutron capture therapy using a fission converter epithermal neutron beam. Appl Radiat Isot 61 (2004) 1075-1081
    • (2004) Appl Radiat Isot , vol.61 , pp. 1075-1081
    • Kiger III, W.S.1    Lu, X.Q.2    Harling, O.K.3
  • 7
    • 0037847454 scopus 로고    scopus 로고
    • Boron neutron capture therapy for glioblastoma multiforme: Clinical studies in Sweden
    • Capala J., Stenstam B.H., Skold K., et al. Boron neutron capture therapy for glioblastoma multiforme: Clinical studies in Sweden. J Neuro-Oncol 62 (2003) 135-144
    • (2003) J Neuro-Oncol , vol.62 , pp. 135-144
    • Capala, J.1    Stenstam, B.H.2    Skold, K.3
  • 8
    • 22944486037 scopus 로고    scopus 로고
    • Epithermal neutron beams for clinical studies of boron neutron capture therapy: A dosimetric comparison of seven beams
    • Binns P.J., Riley K.J., and Harling O.K. Epithermal neutron beams for clinical studies of boron neutron capture therapy: A dosimetric comparison of seven beams. Radiat Res 164 (2005) 212-220
    • (2005) Radiat Res , vol.164 , pp. 212-220
    • Binns, P.J.1    Riley, K.J.2    Harling, O.K.3
  • 10
    • 0027443121 scopus 로고
    • Dosimetric effects of beam size and collimation of epithermal neutrons for boron neutron capture therapy
    • Yanch J.C., and Harling O.K. Dosimetric effects of beam size and collimation of epithermal neutrons for boron neutron capture therapy. Radiat Res 135 (1993) 131-145
    • (1993) Radiat Res , vol.135 , pp. 131-145
    • Yanch, J.C.1    Harling, O.K.2
  • 11
    • 0033958116 scopus 로고    scopus 로고
    • On the optimal energy of epithermal neutron beams for BNCT
    • Bisceglie E., Colangelo P., Colonna N., et al. On the optimal energy of epithermal neutron beams for BNCT. Phys Med Biol 45 (2000) 49-58
    • (2000) Phys Med Biol , vol.45 , pp. 49-58
    • Bisceglie, E.1    Colangelo, P.2    Colonna, N.3
  • 12
    • 0000300438 scopus 로고    scopus 로고
    • Neutronic design of a fission converter-based epithermal neutron beam for neutron capture therapy
    • Kiger III W.S., Sakamoto S., and Harling O.K. Neutronic design of a fission converter-based epithermal neutron beam for neutron capture therapy. Nucl Sci Eng 131 (1999) 1-22
    • (1999) Nucl Sci Eng , vol.131 , pp. 1-22
    • Kiger III, W.S.1    Sakamoto, S.2    Harling, O.K.3
  • 13
    • 0032825525 scopus 로고    scopus 로고
    • Sensitivity studies of beam directionality, beam size, and neutron spectrum for a fission converter-based epithermal neutron beam for boron neutron capture therapy
    • Sakamoto S., Kiger III W.S., and Harling O.K. Sensitivity studies of beam directionality, beam size, and neutron spectrum for a fission converter-based epithermal neutron beam for boron neutron capture therapy. Med Phys 26 (1999) 1979-1988
    • (1999) Med Phys , vol.26 , pp. 1979-1988
    • Sakamoto, S.1    Kiger III, W.S.2    Harling, O.K.3
  • 15
    • 4143063220 scopus 로고    scopus 로고
    • Verification and validation of the NCT treatment planning program
    • Sauerwein W., Moss R., and Wittig A. (Eds), Monduzzi Editore, Bologna, Italy
    • Kiger III W.S., Santa Cruz G.A., Gonzalez S.J., et al. Verification and validation of the NCT treatment planning program. In: Sauerwein W., Moss R., and Wittig A. (Eds). Research and development in neutron capture therapy (2002), Monduzzi Editore, Bologna, Italy 613-616
    • (2002) Research and development in neutron capture therapy , pp. 613-616
    • Kiger III, W.S.1    Santa Cruz, G.A.2    Gonzalez, S.J.3
  • 16
    • 33947536118 scopus 로고    scopus 로고
    • ICRU. Nuclear data for neutron and proton radiotherapy and for radiation protection ICRU Report 63. Bethesda, MD: International Commission on Radiation Units and Measurements; 2000.
  • 17
    • 0036168765 scopus 로고    scopus 로고
    • Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models
    • Goorley J.T., Kiger III W.S., and Zamenhof R.G. Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models. Med Phys 29 (2002) 145-156
    • (2002) Med Phys , vol.29 , pp. 145-156
    • Goorley, J.T.1    Kiger III, W.S.2    Zamenhof, R.G.3
  • 18
    • 0029035152 scopus 로고
    • Head phantoms for neutron capture therapy
    • Harling O.K., Roberts K.A., Moulin D.J., et al. Head phantoms for neutron capture therapy. Med Phys 22 (1995) 579-583
    • (1995) Med Phys , vol.22 , pp. 579-583
    • Harling, O.K.1    Roberts, K.A.2    Moulin, D.J.3
  • 19
    • 4644288420 scopus 로고    scopus 로고
    • Dosimetric measurements with a brain equivalent plastic walled ionization chamber in an epithermal neutron beam
    • Binns P.J., Riley K.J., and Harling O.K. Dosimetric measurements with a brain equivalent plastic walled ionization chamber in an epithermal neutron beam. Radiat Prot Dosim 110 (2004) 687-692
    • (2004) Radiat Prot Dosim , vol.110 , pp. 687-692
    • Binns, P.J.1    Riley, K.J.2    Harling, O.K.3
  • 20
    • 0028053902 scopus 로고
    • Mixed field dosimetry of neutron beams for boron neutron capture therapy at the MITR-II research reactor
    • Rogus R.D., Harling O.K., and Yanch J.C. Mixed field dosimetry of neutron beams for boron neutron capture therapy at the MITR-II research reactor. Med Phys 21 (1994) 1611-1625
    • (1994) Med Phys , vol.21 , pp. 1611-1625
    • Rogus, R.D.1    Harling, O.K.2    Yanch, J.C.3
  • 21
    • 33947499928 scopus 로고    scopus 로고
    • ASTM (American Society for Testing and Materials). E262-97 Standard test method for determining thermal neutron reaction and fluence rates by radioactivation techniques. West Conshohocken, PA: ASTM; 1998.
  • 22
    • 0035089033 scopus 로고    scopus 로고
    • 10B in blood after boronphenylalanine-fructose administration in humans
    • 10B in blood after boronphenylalanine-fructose administration in humans. Radiat Res 155 (2001) 611-618
    • (2001) Radiat Res , vol.155 , pp. 611-618
    • Kiger III, W.S.1    Palmer, M.R.2    Riley, K.J.3
  • 23
    • 0027493191 scopus 로고
    • Derivations of relative biological effectiveness for the high-LET radiations produced during boron neutron capture irradiations of the 9L rat gliosarcoma in-vitro and in-vivo
    • Coderre J.A., Makar M.S., Micca P.L., et al. Derivations of relative biological effectiveness for the high-LET radiations produced during boron neutron capture irradiations of the 9L rat gliosarcoma in-vitro and in-vivo. Int J Radiat Oncol Biol Phys 27 (1993) 1121-1129
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 1121-1129
    • Coderre, J.A.1    Makar, M.S.2    Micca, P.L.3
  • 24
    • 0032939720 scopus 로고    scopus 로고
    • The radiation biology of boron neutron capture therapy
    • Coderre J.A., and Morris G.M. The radiation biology of boron neutron capture therapy. Radiat Res 151 (1999) 1-18
    • (1999) Radiat Res , vol.151 , pp. 1-18
    • Coderre, J.A.1    Morris, G.M.2
  • 25
    • 0025580871 scopus 로고
    • Monte Carlo methods of neutron beam design for neutron capture therapy at the MIT research reactor (MITR-II)
    • Harling O.K., Bernard J.A., and Zamenhof R.G. (Eds), Plenum Press, New York
    • Clement C.D., Choi J.R., Zamenhof R.G., et al. Monte Carlo methods of neutron beam design for neutron capture therapy at the MIT research reactor (MITR-II). In: Harling O.K., Bernard J.A., and Zamenhof R.G. (Eds). Neutron beam design, development, and performance for neutron-capture therapy (1990), Plenum Press, New York 51-69
    • (1990) Neutron beam design, development, and performance for neutron-capture therapy , pp. 51-69
    • Clement, C.D.1    Choi, J.R.2    Zamenhof, R.G.3
  • 26
    • 33947547212 scopus 로고    scopus 로고
    • X-5 Monte Carlo Team. MCNP-A general Monte Carlo N-particle transport code, version 5. Report no. LA-UR-03-1987. Los Alamos National Laboratory, 2005.
  • 27
    • 33947507866 scopus 로고    scopus 로고
    • Goorley JT. MCNP5 tally enhancements for lattices. Report no. LA-UR-04-3400. Los Alamos National Laboratory, 2004.
  • 28
    • 33947525291 scopus 로고    scopus 로고
    • Kiger WS III, Albritton JR, Hochberg AG, et al. Performance enhancements of MCNP4B, MCNP5, and MCNPX for Monte Carlo radiotherapy planning calculations in lattice geometries. Report no. LA-UR-04-4751. Los Alamos National Laboratory, 2004.
  • 29
    • 33947498794 scopus 로고    scopus 로고
    • ICRU. Photon, electron, proton and neutron interaction data for body tissues ICRU Report 46. Bethesda, MD: International Commission on Radiation Units and Measurements; 1992.
  • 30
    • 0006413721 scopus 로고    scopus 로고
    • A tumor control curve for malignant gliomas derived from fast neutron radiotherapy data: Implications for treatment delivery and compound selection
    • Larsson B., Crawford J., and Weinreich R. (Eds), Elsevier Science, Amsterdam
    • Laramore G.E., Wheeler F.J., Wessol D.E., et al. A tumor control curve for malignant gliomas derived from fast neutron radiotherapy data: Implications for treatment delivery and compound selection. In: Larsson B., Crawford J., and Weinreich R. (Eds). Advances in neutron capture therapy (1997), Elsevier Science, Amsterdam 580-587
    • (1997) Advances in neutron capture therapy , pp. 580-587
    • Laramore, G.E.1    Wheeler, F.J.2    Wessol, D.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.