1
-
-
0036742211
-
Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging
-
O. G. Anfinsen, R. F. Berntsen, H. Aass, E. Kongsgaard, and J. P. Amlie, "Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging," Pacing Clin. Electrophysiol., vol. 25, no. 9, pp. 1400-1402, 2002.
-
(2002)
Pacing Clin. Electrophysiol
, vol.25
, Issue.9
, pp. 1400-1402
-
-
Anfinsen, O.G.1
Berntsen, R.F.2
Aass, H.3
Kongsgaard, E.4
Amlie, J.P.5
-
2
-
-
0032933478
-
MRI compatibility and visibility assessment of implantable medical devices
-
B. A. Schueler, T. B. Parrish, J. C. Lin, B. E. Hammer, B. J. Pangrle, E. R. Ritenour, J. Kucharczyk, and C. L. Truwit, "MRI compatibility and visibility assessment of implantable medical devices," J. Magn. Reson. Imag., vol. 9, no. 4, pp. 596-603, 1999.
-
(1999)
J. Magn. Reson. Imag
, vol.9
, Issue.4
, pp. 596-603
-
-
Schueler, B.A.1
Parrish, T.B.2
Lin, J.C.3
Hammer, B.E.4
Pangrle, B.J.5
Ritenour, E.R.6
Kucharczyk, J.7
Truwit, C.L.8
-
3
-
-
33947527257
-
-
FDA Medical Device Report (MDR) Records #351516, #748838, #175218, and #125938.
-
FDA Medical Device Report (MDR) Records #351516, #748838, #175218, and #125938.
-
-
-
-
4
-
-
20344387680
-
Do we need pacemakers resistant to magnetic resonance imaging?
-
W. Irnich, B. Irnich, C. Bartsch, W. A. Stertmann, H. Gufler, and G. Weiler, "Do we need pacemakers resistant to magnetic resonance imaging?," Europace., vol. 7, no. 4, pp. 353-365, 2005.
-
(2005)
Europace
, vol.7
, Issue.4
, pp. 353-365
-
-
Irnich, W.1
Irnich, B.2
Bartsch, C.3
Stertmann, W.A.4
Gufler, H.5
Weiler, G.6
-
5
-
-
0035098415
-
Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs
-
R. Luechinger, F. Duru, M. B. Scheidegger, P. Boesiger, and R. Candinas, "Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs," Pacing Clin. Electrophysiol., vol. 24, no. 2, pp. 199-205, 2001.
-
(2001)
Pacing Clin. Electrophysiol
, vol.24
, Issue.2
, pp. 199-205
-
-
Luechinger, R.1
Duru, F.2
Scheidegger, M.B.3
Boesiger, P.4
Candinas, R.5
-
6
-
-
1842478179
-
Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
-
E. T. Martin, J. A. Coman, F. G. Shellock, C. C. Pulling, R. Fair, and K. Jenkins, "Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla," J. Am. Coll. Cardiol., vol. 43, no. 7, pp. 1315-1324, 2004.
-
(2004)
J. Am. Coll. Cardiol
, vol.43
, Issue.7
, pp. 1315-1324
-
-
Martin, E.T.1
Coman, J.A.2
Shellock, F.G.3
Pulling, C.C.4
Fair, R.5
Jenkins, K.6
-
7
-
-
0028509215
-
Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prostheses exposed to a 1.5-T MR system
-
F. G. Shellock and S. M. Morisoli, "Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prostheses exposed to a 1.5-T MR system," J. Magn. Reson. Imag., vol. 4, no. 5, pp. 756-758, 1994.
-
(1994)
J. Magn. Reson. Imag
, vol.4
, Issue.5
, pp. 756-758
-
-
Shellock, F.G.1
Morisoli, S.M.2
-
8
-
-
14144252694
-
In vivo heating of pacemaker leads during magnetic resonance imaging
-
R. Luechinger, V. A. Zeijlemaker, E. M. Pedersen, P. Mortensen, E. Falk, F. Duru, R. Candinas, and P. Boesiger, "In vivo heating of pacemaker leads during magnetic resonance imaging," Eur. Heart J., vol. 26, no. 4, pp. 376-383, 2005.
-
(2005)
Eur. Heart J
, vol.26
, Issue.4
, pp. 376-383
-
-
Luechinger, R.1
Zeijlemaker, V.A.2
Pedersen, E.M.3
Mortensen, P.4
Falk, E.5
Duru, F.6
Candinas, R.7
Boesiger, P.8
-
9
-
-
0034077462
-
MR imaging and cardiac pacemakers: In-vitro evaluation and in-vivo studies in 51 patients at 0.5 T
-
T. Sommer, C. Vahlhaus, G. Lauck, A. von Smekal, M. Reinke, U. Hofer, W. Block, F. Traber, C. Schneider, J. Gieseke, W. Jung, and H. Schild, "MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T," Radiology, vol. 215, no. 3, pp. 869-879, 2000.
-
(2000)
Radiology
, vol.215
, Issue.3
, pp. 869-879
-
-
Sommer, T.1
Vahlhaus, C.2
Lauck, G.3
von Smekal, A.4
Reinke, M.5
Hofer, U.6
Block, W.7
Traber, F.8
Schneider, C.9
Gieseke, J.10
Jung, W.11
Schild, H.12
-
10
-
-
0036190033
-
Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla
-
A. R. Rezai, D. Finelli, J. A. Nyenhuis, G. Hrdlicka, J. Tkach, A. Sharan, P. Rugieri, P. H. Stypulkowski, and F. G. Shellock, " Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla," J. Magn. Reson. Imag., vol. 15, no. 3, pp. 241-250, 2002.
-
(2002)
J. Magn. Reson. Imag
, vol.15
, Issue.3
, pp. 241-250
-
-
Rezai, A.R.1
Finelli, D.2
Nyenhuis, J.A.3
Hrdlicka, G.4
Tkach, J.5
Sharan, A.6
Rugieri, P.7
Stypulkowski, P.H.8
Shellock, F.G.9
-
11
-
-
0032956495
-
Magnetic resonance imaging with implanted neurostimulators: An in vitro and in vivo study
-
V. M. Tronnier, A. Staubert, S. Hahnel, and A. Sarem-Aslani, "Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study," Neurosurgery, vol. 44, no. 1, pp. 118-125, 1999.
-
(1999)
Neurosurgery
, vol.44
, Issue.1
, pp. 118-125
-
-
Tronnier, V.M.1
Staubert, A.2
Hahnel, S.3
Sarem-Aslani, A.4
-
12
-
-
0036097986
-
Effect of distance and infusion rate on operation of Medfusion 2010 infusion pump during magnetic resonance imaging
-
A. L. Kovac, B. Swanson, C. Elliott, and L. Wetzel, "Effect of distance and infusion rate on operation of Medfusion 2010 infusion pump during magnetic resonance imaging," J. Clin. Anesth., vol. 14, no. 4, pp. 246-251, 2002.
-
(2002)
J. Clin. Anesth
, vol.14
, Issue.4
, pp. 246-251
-
-
Kovac, A.L.1
Swanson, B.2
Elliott, C.3
Wetzel, L.4
-
13
-
-
0025718093
-
MR imaging of patients with implanted drug infusion pumps
-
R. Von Roemeling, R. M. Lanning, and F. A. Eames, "MR imaging of patients with implanted drug infusion pumps," J. Magn. Reson. Imag., vol. 1, no. 1, pp. 77-81, 1991.
-
(1991)
J. Magn. Reson. Imag
, vol.1
, Issue.1
, pp. 77-81
-
-
Von Roemeling, R.1
Lanning, R.M.2
Eames, F.A.3
-
14
-
-
2342627140
-
Metallic electrodes and leads in simultaneous EEG-MRI: Specific absorption rate (SAR) simulation studies
-
L. M. Angelone, A. Potthast, F. Segonne, S. Iwaki, J. W. Belliveau, and G. Bonmassar, "Metallic electrodes and leads in simultaneous EEG-MRI: specific absorption rate (SAR) simulation studies," Bioelectromagnetics, vol. 25, no. 4, pp. 285-295, 2004.
-
(2004)
Bioelectromagnetics
, vol.25
, Issue.4
, pp. 285-295
-
-
Angelone, L.M.1
Potthast, A.2
Segonne, F.3
Iwaki, S.4
Belliveau, J.W.5
Bonmassar, G.6
-
15
-
-
2442570617
-
Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
-
C. M. Collins, W. Liu, J. Wang, R. Gruetter, J. T. Vaughan, K. Ugurbil, and M. B. Smith, "Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz," J. Magn. Reson. Imag., vol. 19, no. 5, pp. 650-656, 2004.
-
(2004)
J. Magn. Reson. Imag
, vol.19
, Issue.5
, pp. 650-656
-
-
Collins, C.M.1
Liu, W.2
Wang, J.3
Gruetter, R.4
Vaughan, J.T.5
Ugurbil, K.6
Smith, M.B.7
-
16
-
-
0034806846
-
Safety of metallic implants in magnetic resonance imaging
-
H. S. Ho, "Safety of metallic implants in magnetic resonance imaging," J.Magn Reson.Imaging, vol. 14, no. 4, pp. 472-477, 2001.
-
(2001)
J.Magn Reson.Imaging
, vol.14
, Issue.4
, pp. 472-477
-
-
Ho, H.S.1
-
17
-
-
0030058959
-
Spatial distribution of high-frequency electromagnetic energy in human head during MRI: Numerical results and measurements
-
Jan
-
D. Simunic, P. Wach, W. Renhart, and R. Stollberger, "Spatial distribution of high-frequency electromagnetic energy in human head during MRI: numerical results and measurements," IEEE Trans. Biomed. Eng., vol. 43, no. 1, pp. 88-94, Jan. 1996.
-
(1996)
IEEE Trans. Biomed. Eng
, vol.43
, Issue.1
, pp. 88-94
-
-
Simunic, D.1
Wach, P.2
Renhart, W.3
Stollberger, R.4
-
18
-
-
0034942717
-
Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility
-
F. Duru, R. Luechinger, M. B. Scheidegger, T. F. Luscher, P. Boesiger, and R. Candinas, "Pacing in magnetic resonance imaging environment: clinical and technical considerations on compatibility," Eur. Heart J., vol. 22, no. 2, pp. 113-124, 2001.
-
(2001)
Eur. Heart J
, vol.22
, Issue.2
, pp. 113-124
-
-
Duru, F.1
Luechinger, R.2
Scheidegger, M.B.3
Luscher, T.F.4
Boesiger, P.5
Candinas, R.6
-
19
-
-
0025364499
-
Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
-
D. G. Norris and J. M. Hutchison, "Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths," Magn. Reson. Imag., vol. 8, no. 1, pp. 33-37, 1990.
-
(1990)
Magn. Reson. Imag
, vol.8
, Issue.1
, pp. 33-37
-
-
Norris, D.G.1
Hutchison, J.M.2
|