메뉴 건너뛰기




Volumn 33, Issue 4, 2007, Pages 500-505

Flow Volume in the Jugular Vein and Related Hemodynamics in the Branches of the Jugular Vein

Author keywords

Internal jugular vein; Internal jugular vein branch; Internal jugular vein valve incompetence; Transient global amnesia; Venous hypertension; Venous reflux

Indexed keywords

BLOOD; BLOOD VESSELS; BRAIN; DISEASES; IMAGING TECHNIQUES; NEUROLOGY; ULTRASONOGRAPHY;

EID: 33947531132     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2006.10.009     Document Type: Article
Times cited : (34)

References (17)
  • 1
    • 0028016213 scopus 로고
    • Venous changes occurring during the Valsalva maneuver: evaluation by intravascular ultrasound
    • Attubato M.J., Katz E.S., Feit F., et al. Venous changes occurring during the Valsalva maneuver: evaluation by intravascular ultrasound. Am J Cardiol 74 (1994) 408-410
    • (1994) Am J Cardiol , vol.74 , pp. 408-410
    • Attubato, M.J.1    Katz, E.S.2    Feit, F.3
  • 2
    • 0021961767 scopus 로고
    • Ultrasonic evaluation of jugular venous valve competence
    • Brownlow Jr. R.L., and McKinney W.M. Ultrasonic evaluation of jugular venous valve competence. J Ultrasound Med 4 (1985) 169-172
    • (1985) J Ultrasound Med , vol.4 , pp. 169-172
    • Brownlow Jr., R.L.1    McKinney, W.M.2
  • 3
    • 20544443223 scopus 로고    scopus 로고
    • Cough headache and thoracic inlet valvular competence in uremia
    • Chuang Y.M., and Hu H.H. Cough headache and thoracic inlet valvular competence in uremia. Eur Neurol 53 (2005) 78-80
    • (2005) Eur Neurol , vol.53 , pp. 78-80
    • Chuang, Y.M.1    Hu, H.H.2
  • 4
    • 33745894626 scopus 로고    scopus 로고
    • Detection of intracranial venous reflux in patients of transient global amnesia
    • Chung C.P., Hsu H.Y., Chang F.C., Sheng W.Y., and Hu H.H. Detection of intracranial venous reflux in patients of transient global amnesia. Neurology 66 (2006) 1873-1877
    • (2006) Neurology , vol.66 , pp. 1873-1877
    • Chung, C.P.1    Hsu, H.Y.2    Chang, F.C.3    Sheng, W.Y.4    Hu, H.H.5
  • 5
    • 0033938625 scopus 로고    scopus 로고
    • Using internal jugular pulsations as a manometer for right atrial pressure measurements
    • Constant J. Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology 93 (2000) 26-30
    • (2000) Cardiology , vol.93 , pp. 26-30
    • Constant, J.1
  • 7
  • 8
    • 6444235400 scopus 로고    scopus 로고
    • Human cerebral venous outflow pathway depends on posture and central venous pressure
    • Gisolf J., van Lieshout J., van Heusden K., et al. Human cerebral venous outflow pathway depends on posture and central venous pressure. J Physiol 501 (2004) 317-327
    • (2004) J Physiol , vol.501 , pp. 317-327
    • Gisolf, J.1    van Lieshout, J.2    van Heusden, K.3
  • 10
    • 0032147256 scopus 로고    scopus 로고
    • A etiology of transient global amnesia
    • Lewis S.L. A etiology of transient global amnesia. Lancet 352 (1998) 397-399
    • (1998) Lancet , vol.352 , pp. 397-399
    • Lewis, S.L.1
  • 11
    • 0025106066 scopus 로고
    • Internal jugular venous flow measurement by means of a duplex scanner
    • Muller H.R., Hinn G., and Buser M.W. Internal jugular venous flow measurement by means of a duplex scanner. J Ultrasound Med 9 (1990) 261-265
    • (1990) J Ultrasound Med , vol.9 , pp. 261-265
    • Muller, H.R.1    Hinn, G.2    Buser, M.W.3
  • 12
    • 14844303781 scopus 로고    scopus 로고
    • An animal model of venous hypertension: The role of inflammation in venous valve failure
    • Pascarella L., Schmid-Schonbein G.W., and Bergan J. An animal model of venous hypertension: The role of inflammation in venous valve failure. J Vasc Surg 41 (2005) 303-311
    • (2005) J Vasc Surg , vol.41 , pp. 303-311
    • Pascarella, L.1    Schmid-Schonbein, G.W.2    Bergan, J.3
  • 13
    • 0034627267 scopus 로고    scopus 로고
    • Disturbance of venous flow patterns in patients with transient global amnesia
    • Sander D., Winbeck K., Etgen T., et al. Disturbance of venous flow patterns in patients with transient global amnesia. Lancet 356 (2000) 1982-1984
    • (2000) Lancet , vol.356 , pp. 1982-1984
    • Sander, D.1    Winbeck, K.2    Etgen, T.3
  • 15
    • 0036245067 scopus 로고    scopus 로고
    • The internal jugular vein valve may have a significant role in the prevention of venous reflux: Evidence from live and cadaveric human subjects
    • Silva M.A., Deen K.I., Fernando D.J., and Sheriffdeen A.H. The internal jugular vein valve may have a significant role in the prevention of venous reflux: Evidence from live and cadaveric human subjects. Clin Physiol Funct Imaging 22 (2002) 202-205
    • (2002) Clin Physiol Funct Imaging , vol.22 , pp. 202-205
    • Silva, M.A.1    Deen, K.I.2    Fernando, D.J.3    Sheriffdeen, A.H.4
  • 17
    • 0020623452 scopus 로고
    • The middle thyroid vein: An alternate route for central venous catheter insertion
    • Toufanian A., and Knight P. The middle thyroid vein: An alternate route for central venous catheter insertion. J Pediatr Surg 18 (1983) 156-157
    • (1983) J Pediatr Surg , vol.18 , pp. 156-157
    • Toufanian, A.1    Knight, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.