메뉴 건너뛰기




Volumn 10, Issue 1, 2007, Pages 42-46

Clinical evaluation of dual-dialyzer hemodialysis (DDHD)

Author keywords

2MG, 2 Microglobulin; DDHD; Dual dialyzer hemodialysis; Internal filtration

Indexed keywords

BETA 2 MICROGLOBULIN; WATER;

EID: 33947525443     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-006-0362-z     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0037591826 scopus 로고    scopus 로고
    • Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound
    • 2
    • Y Sato M Mineshima I Ishimori I Kaneko T Akiba S Teraoka 2003 Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound Int J Artif Organs 26 2 129 134
    • (2003) Int J Artif Organs , vol.26 , pp. 129-134
    • Sato, Y.1    Mineshima, M.2    Ishimori, I.3    Kaneko, I.4    Akiba, T.5    Teraoka, S.6
  • 2
    • 0016911147 scopus 로고
    • Short-duration, high-area regular dialysis using two UF 2 coils in series
    • JB Ari A Open GM Berlyne 1976 Short-duration, high-area regular dialysis using two UF 2 coils in series Nephron 16 74 79
    • (1976) Nephron , vol.16 , pp. 74-79
    • Ari, J.B.1    Open, A.2    Berlyne, G.M.3
  • 3
    • 0033979598 scopus 로고    scopus 로고
    • Improved urea reduction ratio and Kt/V in large hemodialysis patients using two dialyzers in parallel
    • 2
    • KM Powers MJ Wilkowski AW Helmandollar KG Koenig WK Bolton 2000 Improved urea reduction ratio and Kt/V in large hemodialysis patients using two dialyzers in parallel Am J Kidney Dis 35 2 266 274
    • (2000) Am J Kidney Dis , vol.35 , pp. 266-274
    • Powers, K.M.1    Wilkowski, M.J.2    Helmandollar, A.W.3    Koenig, K.G.4    Bolton, W.K.5
  • 9
    • 33947496574 scopus 로고    scopus 로고
    • (in Japanese)
    • High performance membrane 98 1998;45:126-129 (in Japanese)
    • (1998) High Performance Membrane 98 , vol.45 , pp. 126-129
  • 10
    • 0033868074 scopus 로고    scopus 로고
    • Effects of a reduced inner diameter of hollow fibers in hemodialyzers
    • 2
    • C Ronco A Brendolan A Lupi G Metry NW Levin 2000 Effects of a reduced inner diameter of hollow fibers in hemodialyzers Kidney Int 58 2 809 817
    • (2000) Kidney Int , vol.58 , pp. 809-817
    • Ronco, C.1    Brendolan, A.2    Lupi, A.3    Metry, G.4    Levin, N.W.5
  • 11
    • 0029880481 scopus 로고    scopus 로고
    • Performance evaluation of a plug dialyser for large volume exchange dialysers
    • 1. in Japanese
    • N Hosoya M Sasaki S Takesawa 1996 Performance evaluation of a plug dialyser for large volume exchange dialysers Artif. Organs 25 1 107 112 in Japanese
    • (1996) Artif. Organs , vol.25 , pp. 107-112
    • Hosoya, N.1    Sasaki, M.2    Takesawa, S.3
  • 13
    • 0020262521 scopus 로고
    • Infusion-free hemodiafiltration: Simultaneous hemofiltration and dialysis with no need for infusion fluid
    • 4
    • T Shinzato R Sezaki M Usuda K Maeda S Ohbayashi T Toyota 1982 Infusion-free hemodiafiltration: simultaneous hemofiltration and dialysis with no need for infusion fluid Artif Organs 6 4 453 456
    • (1982) Artif Organs , vol.6 , pp. 453-456
    • Shinzato, T.1    Sezaki, R.2    Usuda, M.3    Maeda, K.4    Ohbayashi, S.5    Toyota, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.