메뉴 건너뛰기




Volumn 221, Issue 1, 2007, Pages 81-86

Technical factors affecting cup stability in bone impaction grafting

Author keywords

Arthroplasty cement; Bone graft; Hip; Revision

Indexed keywords

COMPUTER SIMULATION; DEFECTS; GRAFTS; HIP PROSTHESES; MECHANICAL TESTING; PHOTOGRAMMETRY; BONE; DYNAMIC LOADS; GRAFTING (CHEMICAL); HOT ISOSTATIC PRESSING; LOAD TESTING; REAMING; STABILITY;

EID: 33947366379     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM245     Document Type: Article
Times cited : (24)

References (26)
  • 1
    • 0035217857 scopus 로고    scopus 로고
    • Cemented total hip arthroplasty with impacted morcellized bone-grafts to restore acetabular bone defects in congenital hip dysplasia
    • Bolder, S. B. T., Melenhorst, J., Gardeniers, J. W. M., Slooff, T. J. J. H., Veth, R. P. H., and Schreurs, B. W. Cemented total hip arthroplasty with impacted morcellized bone-grafts to restore acetabular bone defects in congenital hip dysplasia. J. Arthroplasty, 2001, 16, 164-169.
    • (2001) J. Arthroplasty , vol.16 , pp. 164-169
    • Bolder, S.B.T.1    Melenhorst, J.2    Gardeniers, J.W.M.3    Slooff, T.J.J.H.4    Veth, R.P.H.5    Schreurs, B.W.6
  • 2
    • 2442680429 scopus 로고    scopus 로고
    • Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup. A 15- to 20-year follow-up
    • Schreurs, B. W., Bolder, S. B. T., Gardeniers, J. W. M., Verdonschot, N., Slooff, T. J. J. H., and Veth, R. P. H. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup. A 15- to 20-year follow-up. J. Bone Jt Surg., 2004, 86B, 492-497.
    • (2004) J. Bone Jt Surg. , vol.86 B , pp. 492-497
    • Schreurs, B.W.1    Bolder, S.B.T.2    Gardeniers, J.W.M.3    Verdonschot, N.4    Slooff, T.J.J.H.5    Veth, R.P.H.6
  • 3
    • 8144220496 scopus 로고    scopus 로고
    • Acetabular reconstruction with impaction bone-grafting and a cemented cup in patients younger than fifty years old
    • Schreurs, B. W., Busch, V. J., Welten, M. L. M., Verdonschot, N., Slooff, T. J. J. H., and Gardeniers, J. W. M. Acetabular reconstruction with impaction bone-grafting and a cemented cup in patients younger than fifty years old. J. Bone Jt Surg., 2004, 86A, 2385-2392.
    • (2004) J. Bone Jt Surg. , vol.86 A , pp. 2385-2392
    • Schreurs, B.W.1    Busch, V.J.2    Welten, M.L.M.3    Verdonschot, N.4    Slooff, T.J.J.H.5    Gardeniers, J.W.M.6
  • 4
    • 4544328586 scopus 로고    scopus 로고
    • Impaction bone-grafting in revision joint replacement surgery
    • Toms, A. D., Barker, R. L., Jones, R. S. and Kuiper, J. H. Impaction bone-grafting in revision joint replacement surgery. J Bone Jt Surg., 2004, 86A, 2050-2060.
    • (2004) J. Bone Jt Surg. , vol.86 A , pp. 2050-2060
    • Toms, A.D.1    Barker, R.L.2    Jones, R.S.3    Kuiper, J.H.4
  • 5
    • 0033766450 scopus 로고    scopus 로고
    • Acetabular reconstruction with impacted morsellised cancellous bone autografts and cemented primary total hip arthroplasty. A 10- to 17-year follow-up study
    • Welten, M. L. M., Schreurs, B. W., Buma, P., Verdonschot, N., and Slooff, T. J. J. H. Acetabular reconstruction with impacted morsellised cancellous bone autografts and cemented primary total hip arthroplasty. A 10- to 17-year follow-up study. J. Arthroplasty, 2000, 15, 819-824.
    • (2000) J. Arthroplasty , vol.15 , pp. 819-824
    • Welten, M.L.M.1    Schreurs, B.W.2    Buma, P.3    Verdonschot, N.4    Slooff, T.J.J.H.5
  • 7
    • 33645770975 scopus 로고    scopus 로고
    • Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups. Experiments using a synthetic acetabular model
    • Arts, J. J. C., Verdonschot, N., Buma, P., and Schreurs, B. W. Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups. Experiments using a synthetic acetabular model. Acta Orthop. Scand., 2006, 77, 227-233.
    • (2006) Acta Orthop. Scand. , vol.77 , pp. 227-233
    • Arts, J.J.C.1    Verdonschot, N.2    Buma, P.3    Schreurs, B.W.4
  • 8
    • 0347601727 scopus 로고    scopus 로고
    • Particle size of bone graft and method of impaction affect initial stability of cemented cups: Human cadaveric and synthetic pelvic specimen studies
    • Bolder, S. B. T., Schreurs, B. W., Verdonschot, N., van Unen, J. M. J., Gardeniers, J. W. M., and Slooff, T. J. J. H. Particle size of bone graft and method of impaction affect initial stability of cemented cups: human cadaveric and synthetic pelvic specimen studies. Acta Orthop. Scand, 2003, 74, 652-657.
    • (2003) Acta Orthop. Scand , vol.74 , pp. 652-657
    • Bolder, S.B.T.1    Schreurs, B.W.2    Verdonschot, N.3    van Unen, J.M.J.4    Gardeniers, J.W.M.5    Slooff, T.J.J.H.6
  • 9
    • 0033949591 scopus 로고    scopus 로고
    • Bigger size and defatting of bone chips will increase cup stability
    • Ullmark, G. Bigger size and defatting of bone chips will increase cup stability. Arch. Orthop. Tauma Surg., 2000, 120, 445-447.
    • (2000) Arch. Orthop. Tauma Surg. , vol.120 , pp. 445-447
    • Ullmark, G.1
  • 10
    • 0022894894 scopus 로고
    • Use of the acetabular reamer to harvest autogeneic bone graft material: A simple method for producing bone paste
    • Dick, W. Use of the acetabular reamer to harvest autogeneic bone graft material: a simple method for producing bone paste. Arch. Orthop. Trauma, 1986, 105, 235-238.
    • (1986) Arch. Orthop. Trauma , vol.105 , pp. 235-238
    • Dick, W.1
  • 11
    • 0024831727 scopus 로고
    • A technique for obtaining bone graft
    • Sanders, R. and DiPasquale, T. A technique for obtaining bone graft. J. Orthop. Trauma, 1989, 3, 287-289.
    • (1989) J. Orthop. Trauma , vol.3 , pp. 287-289
    • Sanders, R.1    DiPasquale, T.2
  • 12
    • 0034777580 scopus 로고    scopus 로고
    • Anterior iliac crest bone graft harvesting using the corticocancellous reamer system
    • Westrich, G. H., Geller, D. S., O'Malley, M. J., Deland, J. T., and Helfet, D. L. Anterior iliac crest bone graft harvesting using the corticocancellous reamer system. J. Orthop. Trauma, 2001, 15, 500-506.
    • (2001) J. Orthop. Trauma , vol.15 , pp. 500-506
    • Westrich, G.H.1    Geller, D.S.2    O'Malley, M.J.3    Deland, J.T.4    Helfet, D.L.5
  • 13
    • 8644254256 scopus 로고    scopus 로고
    • The incorporation of morselized bone grafts in cementless acetabular revisions
    • Etienne, G., Bezwada, H. P., Hungerford, D. S., and Mont, M. A. The incorporation of morselized bone grafts in cementless acetabular revisions. Clin. Orthop. Relat. Res., 2004, 428, 241-246.
    • (2004) Clin. Orthop. Relat. Res. , vol.428 , pp. 241-246
    • Etienne, G.1    Bezwada, H.P.2    Hungerford, D.S.3    Mont, M.A.4
  • 14
    • 0032872182 scopus 로고    scopus 로고
    • Acetabular reconstruction with morcellized allograft and ring support: A medium-term review
    • Haddad, E S., Shergill, N., and Muirhead-Allwood, S. K. Acetabular reconstruction with morcellized allograft and ring support: a medium-term review. J. Arthroplasty, 1999, 14, 788-795.
    • (1999) J. Arthroplasty , vol.14 , pp. 788-795
    • Haddad, E.S.1    Shergill, N.2    Muirhead-Allwood, S.K.3
  • 17
    • 23044475618 scopus 로고    scopus 로고
    • Cemented cup stability during lever-out testing after acetabular bone impaction grafting with bone graft substitutes mixes containing morselized cancellous bone and tricalcium phosphate-hydroxyapatite granules
    • Arts, J. J. C., Schreurs, B. W., Buma, P., and Verdonschot, N. Cemented cup stability during lever-out testing after acetabular bone impaction grafting with bone graft substitutes mixes containing morselized cancellous bone and tricalcium phosphate-hydroxyapatite granules. Proc. ImechE, Part H: J. Engineering in Medicine, 2005, 219, 257-263.
    • (2005) Proc. ImechE, Part H: J. Engineering in Medicine , vol.219 , pp. 257-263
    • Arts, J.J.C.1    Schreurs, B.W.2    Buma, P.3    Verdonschot, N.4
  • 18
    • 0036132507 scopus 로고    scopus 로고
    • Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles
    • Bolder, S. B. T., Verdonschot, N., Schreurs, B. W., and Buma, P. Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. Biomaterials, 2002, 23, 659-666.
    • (2002) Biomaterials , vol.23 , pp. 659-666
    • Bolder, S.B.T.1    Verdonschot, N.2    Schreurs, B.W.3    Buma, P.4
  • 19
    • 0346157398 scopus 로고    scopus 로고
    • The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with TCP/HA particles in bone impaction grafting
    • Bolder, S. B. T., Verdonschot, N., Schreurs, B. W., and Buma, P. The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with TCP/HA particles in bone impaction grafting. J. Arthroplasty, 2003, 18, 1056-1063.
    • (2003) J. Arthroplasty , vol.18 , pp. 1056-1063
    • Bolder, S.B.T.1    Verdonschot, N.2    Schreurs, B.W.3    Buma, P.4
  • 20
    • 0000295637 scopus 로고    scopus 로고
    • The effect of bone chip size on initial stability following femoral impaction grafting
    • Eldridge, J. D. J., Hubble, M. J. W., Nelson, K., Smith, E. J., and Learmonth, I. D. The effect of bone chip size on initial stability following femoral impaction grafting. J. Bone Jt Surg., 1997, 79B, Suppl. 3, 364.
    • (1997) J. Bone Jt Surg. , vol.79 B , Issue.SUPPL. 3 , pp. 364
    • Eldridge, J.D.J.1    Hubble, M.J.W.2    Nelson, K.3    Smith, E.J.4    Learmonth, I.D.5
  • 21
    • 0029803542 scopus 로고    scopus 로고
    • Femoral component revision using impacted morsellised cancellous bone graft
    • Malkani, A. L., Voor, M. J., Fee, K. A., and Bates, C. S. Femoral component revision using impacted morsellised cancellous bone graft. J. Bone Jt Surg., 1996, 78B, 973-978.
    • (1996) J. Bone Jt Surg. , vol.78 B , pp. 973-978
    • Malkani, A.L.1    Voor, M.J.2    Fee, K.A.3    Bates, C.S.4
  • 23
    • 0000044627 scopus 로고    scopus 로고
    • Does size matter? An investigation into the effects of particle size on the impaction grafting in vitro
    • Wallace, I. W., Ammon, P. R., Day, R., Lee, D. A., and Beave, R. J. Does size matter? An investigation into the effects of particle size on the impaction grafting in vitro. J. Bone Jt Surg., 1997, 79B, Suppl. 3, 366.
    • (1997) J. Bone Jt Surg. , vol.79 B , Issue.SUPPL. 3 , pp. 366
    • Wallace, I.W.1    Ammon, P.R.2    Day, R.3    Lee, D.A.4    Beave, R.J.5
  • 24
    • 0037697854 scopus 로고    scopus 로고
    • Techniques to improve the shear strength of impacted bone graft: The effect of particle size and washing of the graft
    • Dunlop, D. G., Brewster, N. T., Madabhushi, S. P. G., Usmani, A. S., Pankaj, P., and Howie, C. R. Techniques to improve the shear strength of impacted bone graft: the effect of particle size and washing of the graft. J. Bone Jt Surg., 2003, 85A, 639-646.
    • (2003) J. Bone Jt Surg. , vol.85 A , pp. 639-646
    • Dunlop, D.G.1    Brewster, N.T.2    Madabhushi, S.P.G.3    Usmani, A.S.4    Pankaj, P.5    Howie, C.R.6
  • 26
    • 0034806932 scopus 로고    scopus 로고
    • Time-dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting
    • Verdonschot, N., van Hal, C. T. H., Schreurs, B. W., Buma, P., Hulskes, R., and Slooff, T. J. J. H. Time-dependent mechanical properties of HA/ TCP particles in relation to morsellized bone grafts for use in impaction grafting. J. Biomed. Mater Res., 2001, 58, 599-604.
    • (2001) J. Biomed. Mater Res. , vol.58 , pp. 599-604
    • Verdonschot, N.1    van Hal, C.T.H.2    Schreurs, B.W.3    Buma, P.4    Hulskes, R.5    Slooff, T.J.J.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.