-
1
-
-
0022564470
-
A technique for pressure measurement in the active electrical zone of a wire-cylinder electrostatic precipitator
-
Weaver M and Shaughnessy E 1986 A technique for pressure measurement in the active electrical zone of a wire-cylinder electrostatic precipitator IEEE Trans. Indust. Appl. 22 235-9
-
(1986)
IEEE Trans. Indust. Appl.
, vol.22
, pp. 235-239
-
-
Weaver, M.1
Shaughnessy, E.2
-
2
-
-
0017957952
-
EHD study of the corona wind between wire and plate electrodes
-
Yabe A, Mori Y and Hijikata K 1978 EHD study of the corona wind between wire and plate electrodes AIAA J. 16 341-5
-
(1978)
AIAA J.
, vol.16
, pp. 340-345
-
-
Yabe, A.1
Mori, Y.2
Hijikata, K.3
-
3
-
-
0023215010
-
High-temperature high-pressure electrostatic precipitator electrical characterization and collection efficiency
-
Rinard G, Rugg D and Yamamoto T 1987 High-temperature high-pressure electrostatic precipitator electrical characterization and collection efficiency IEEE Trans. Indust. Appl. 23 115-9
-
(1987)
IEEE Trans. Indust. Appl.
, vol.23
, pp. 114-119
-
-
Rinard, G.1
Rugg, D.2
Yamamoto, T.3
-
4
-
-
0038725727
-
Current-voltage characteristics of corona in rod-plane gaps as influenced by temperature
-
Abdel-Salam M and Allen N 2003 Current-voltage characteristics of corona in rod-plane gaps as influenced by temperature IEE Proc. Sci. Meas. Technol. 150 135-9
-
(2003)
IEE Proc. Sci. Meas. Technol.
, vol.150
, Issue.3
, pp. 135-139
-
-
Abdel-Salam, M.1
Allen, N.2
-
5
-
-
0014509536
-
Analysis of corona losses on dc transmission lines: I. Unipolar corona
-
Sarma M P and Janischewskyj W 1969 Analysis of corona losses on dc transmission lines: I. Unipolar corona IEEE Trans. Power Appl. Syst. 88 718-31
-
(1969)
IEEE Trans. Power Appl. Syst.
, vol.88
, pp. 718-731
-
-
Sarma, M.P.1
Janischewskyj, W.2
-
9
-
-
0032494305
-
The onset voltage of coronas on bare and coated conductors
-
Abdel-Salam M, Turkey A and Hashem A 1998 The onset voltage of coronas on bare and coated conductors J. Phys. D: Appl. Phys. 31 2550-6
-
(1998)
J. Phys. D: Appl. Phys.
, vol.31
, Issue.19
, pp. 2550-2556
-
-
Abdel-Salam, M.1
Turkey, A.2
Hashem, A.3
-
10
-
-
0021855742
-
Positive wire-to-plane coronas as influenced by atmospheric humidity
-
Abdel-Salam M 1985 Positive wire-to-plane coronas as influenced by atmospheric humidity IEEE Trans. Indust. Appl. 21 35-40
-
(1985)
IEEE Trans. Indust. Appl.
, vol.21
, pp. 35-40
-
-
Abdel-Salam, M.1
-
11
-
-
33846881833
-
Positive corona inception in point-plane gaps as influenced by a surrounding dielectric enclosure
-
Abdel-Salam M and Hashem A 2006 Positive corona inception in point-plane gaps as influenced by a surrounding dielectric enclosure J. Phys. D: Appl. Phys. 39 5169-75
-
(2006)
J. Phys. D: Appl. Phys.
, vol.39
, Issue.24
, pp. 5169-5175
-
-
Abdel-Salam, M.1
Hashem, A.2
-
14
-
-
0037284953
-
Model of the negative dc corona plasma: Comparison to the positive dc corona plasma
-
Chen J and Davidson J H 2003 Model of the negative dc corona plasma: comparison to the positive dc corona plasma Plasma Chem. Plasma Process. 23 83-102
-
(2003)
Plasma Chem. Plasma Process.
, vol.23
, Issue.1
, pp. 83-102
-
-
Chen, J.1
Davidson, J.H.2
-
15
-
-
33947359002
-
Physical conditions for the formation of an ac discharge
-
Alexandrov G N 1956 Physical conditions for the formation of an ac discharge J. Tech. Phys. (USSR) 26 1769-81
-
(1956)
J. Tech. Phys. (USSR)
, vol.26
, pp. 1769-1781
-
-
Alexandrov, G.N.1
-
16
-
-
0027554523
-
Calculation of corona onset voltage for duct-type precipitators
-
Abdel-Salam M and Wiitanen D 1993 Calculation of corona onset voltage for duct-type precipitators IEEE Trans. Indust. Appl. 29 174-80
-
(1993)
IEEE Trans. Indust. Appl.
, vol.29
, Issue.2
, pp. 274-180
-
-
Abdel-Salam, M.1
Wiitanen, D.2
-
17
-
-
0038603372
-
Calculating the effect of high temperatures on the onset voltages of negative discharges
-
Abdel-Salam M 1976 Calculating the effect of high temperatures on the onset voltages of negative discharges J. Phys. D: Appl. Phys. 9 L149-54
-
(1976)
J. Phys. D: Appl. Phys.
, vol.9
, Issue.12
-
-
Abdel-Salam, M.1
-
21
-
-
0022581946
-
DC corona discharge characteristics and ion-flow distribution for several types of rods under low-pressure
-
Watanabe T, Fujinami H, Takuma T and Sunaga Y 1986 DC corona discharge characteristics and ion-flow distribution for several types of rods under low-pressure IEEE Trans. Indust. Appl. 22 547-53
-
(1986)
IEEE Trans. Indust. Appl.
, vol.22
, pp. 547-553
-
-
Watanabe, T.1
Fujinami, H.2
Takuma, T.3
Sunaga, Y.4
-
26
-
-
0005821546
-
DC corona on smooth conductors in air
-
Sarma M P and Janischewskyj W 1969 DC corona on smooth conductors in air Proc. IEE 116 161-6
-
(1969)
Proc. IEE
, vol.116
, Issue.1
, pp. 161-166
-
-
Sarma, M.P.1
Janischewskyj, W.2
|