메뉴 건너뛰기




Volumn 23, Issue 3, 2007, Pages 284-289

Astigmatism and the impact of relaxing incisions after penetrating keratoplasty

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASTIGMATISM; CONGENITAL CORNEA DYSTROPHY; CONTROLLED STUDY; CORNEA TRANSPLANTATION; HUMAN; INCISION; KERATOCONUS; KERATOPATHY; MAJOR CLINICAL STUDY; PENETRATING KERATOPLASTY; PRIORITY JOURNAL; REFRACTIVE SURGERY; SWEDEN; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 33947363405     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20070301-12     Document Type: Article
Times cited : (17)

References (18)
  • 3
    • 0036163820 scopus 로고    scopus 로고
    • Visual outcome in corneal grafts: A preliminary analysis of the Swedish Corneal Transplant Register
    • Claesson M, Armitage WJ, Fagerholm P, Stenevi U. Visual outcome in corneal grafts: a preliminary analysis of the Swedish Corneal Transplant Register. Br J Ophthalmol. 2002;86:174-180.
    • (2002) Br J Ophthalmol , vol.86 , pp. 174-180
    • Claesson, M.1    Armitage, W.J.2    Fagerholm, P.3    Stenevi, U.4
  • 4
    • 0027102466 scopus 로고
    • A method for assessing the accuracy of surgical technique in the correction of astigmatism
    • Kaye SB, Campbell SH, Davey K, Patterson A. A method for assessing the accuracy of surgical technique in the correction of astigmatism. Br J Ophthalmol. 1992;76:738-740.
    • (1992) Br J Ophthalmol , vol.76 , pp. 738-740
    • Kaye, S.B.1    Campbell, S.H.2    Davey, K.3    Patterson, A.4
  • 5
    • 0032936566 scopus 로고    scopus 로고
    • Proposed classification for topographic patterns seen after penetrating keratoplasty
    • Karabatsas CH, Cook SD, Sparrow JM. Proposed classification for topographic patterns seen after penetrating keratoplasty. Br J Ophthalmol. 1999;83:403-409.
    • (1999) Br J Ophthalmol , vol.83 , pp. 403-409
    • Karabatsas, C.H.1    Cook, S.D.2    Sparrow, J.M.3
  • 6
    • 0025322759 scopus 로고
    • Classification of normal corneal topography based on computer-assisted videokeratography
    • Bogan SJ, Waring GO III, Ibrahim O, Drews C, Curtis L. Classification of normal corneal topography based on computer-assisted videokeratography. Arch Ophthalmol. 1990;108:945-949.
    • (1990) Arch Ophthalmol , vol.108 , pp. 945-949
    • Bogan, S.J.1    Waring III, G.O.2    Ibrahim, O.3    Drews, C.4    Curtis, L.5
  • 7
    • 0034846466 scopus 로고    scopus 로고
    • Astigmatism and the analysis of its surgical correction
    • Morlet N, Minassian D, Dart J. Astigmatism and the analysis of its surgical correction. Br J Ophthalmol. 2001;85:1127-1138.
    • (2001) Br J Ophthalmol , vol.85 , pp. 1127-1138
    • Morlet, N.1    Minassian, D.2    Dart, J.3
  • 9
    • 3042743788 scopus 로고    scopus 로고
    • Long term analysis of LASIK for correction of refractive errors after penetrating keratoplasty
    • Hardten DR, Chittcharus A, Lindstrom RL. Long term analysis of LASIK for correction of refractive errors after penetrating keratoplasty. Cornea. 2004;23:479-489.
    • (2004) Cornea , vol.23 , pp. 479-489
    • Hardten, D.R.1    Chittcharus, A.2    Lindstrom, R.L.3
  • 10
    • 0033748484 scopus 로고    scopus 로고
    • Rashad KM. Laser in situ keratomileusis for correction of high astigmatism after penetrating keratoplasty. J Refract Surg. 2000;16:701-710.
    • Rashad KM. Laser in situ keratomileusis for correction of high astigmatism after penetrating keratoplasty. J Refract Surg. 2000;16:701-710.
  • 11
    • 0034971023 scopus 로고    scopus 로고
    • Correction of irregular astigmatism with excimer laser assisted by sodium hyaluronate
    • Alio JL, Belda JI, Shalaby AM. Correction of irregular astigmatism with excimer laser assisted by sodium hyaluronate. Ophthalmology. 2001;108:1246-1260.
    • (2001) Ophthalmology , vol.108 , pp. 1246-1260
    • Alio, J.L.1    Belda, J.I.2    Shalaby, A.M.3
  • 12
    • 2942612336 scopus 로고    scopus 로고
    • Artisan toric lens implantation for correction of postkeratoplasty astigmatism
    • Nuijts RM, Abhilakh Missier KA, Nabar VA, Japing WJ. Artisan toric lens implantation for correction of postkeratoplasty astigmatism. Ophthalmology. 2004;111:1086-1094.
    • (2004) Ophthalmology , vol.111 , pp. 1086-1094
    • Nuijts, R.M.1    Abhilakh Missier, K.A.2    Nabar, V.A.3    Japing, W.J.4
  • 14
    • 2142828614 scopus 로고    scopus 로고
    • Photorefractive keratectomy with mitomycin C for the management of a LASIK flap complication following a penetrating keratoplasty
    • Solomon R, Donnenfeld ED, Perry HD. Photorefractive keratectomy with mitomycin C for the management of a LASIK flap complication following a penetrating keratoplasty. Cornea. 2004;23:403-405.
    • (2004) Cornea , vol.23 , pp. 403-405
    • Solomon, R.1    Donnenfeld, E.D.2    Perry, H.D.3
  • 15
    • 3343015509 scopus 로고    scopus 로고
    • Corneal lamellar flap retraction after LASIK following penetrating keratoplasty
    • Chan CC, Rootman DS. Corneal lamellar flap retraction after LASIK following penetrating keratoplasty. Cornea. 2004;23:643-646.
    • (2004) Cornea , vol.23 , pp. 643-646
    • Chan, C.C.1    Rootman, D.S.2
  • 16
    • 0027938479 scopus 로고
    • Relaxing incisions with compression sutures for control of astigmatism after penetrating keratoplasty
    • Jacobi PC, Hartmann C, Severin M, Bartz-Schmidt KU. Relaxing incisions with compression sutures for control of astigmatism after penetrating keratoplasty. Graefes Arch Clin Exp Ophthalmol. 1994;232:527-532.
    • (1994) Graefes Arch Clin Exp Ophthalmol , vol.232 , pp. 527-532
    • Jacobi, P.C.1    Hartmann, C.2    Severin, M.3    Bartz-Schmidt, K.U.4
  • 17
    • 0026324001 scopus 로고
    • Refractive surgery for graft-induced astigmatism after penetrating keratoplasty for keratoconus
    • Kirkness CM, Ficker LA, Steele AD, Rice NS. Refractive surgery for graft-induced astigmatism after penetrating keratoplasty for keratoconus. Ophthalmology. 1991;98:1786-1792.
    • (1991) Ophthalmology , vol.98 , pp. 1786-1792
    • Kirkness, C.M.1    Ficker, L.A.2    Steele, A.D.3    Rice, N.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.