메뉴 건너뛰기




Volumn 14, Issue 2, 2007, Pages 150-152

How serious a problem for myocardial perfusion assessment is moderate misregistration between SPECT and CT?

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOCARDIOGRAPHY; ARTIFACT; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; DISEASE SEVERITY; EDITORIAL; FALSE NEGATIVE RESULT; FALSE POSITIVE RESULT; HEART MUSCLE PERFUSION; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; LUNG DISEASE; MYOCARDIAL DISEASE; PREVALENCE; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;

EID: 33947362487     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nuclcard.2007.01.033     Document Type: Editorial
Times cited : (4)

References (11)
  • 1
    • 33947374389 scopus 로고    scopus 로고
    • Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    • Goetze S., Wahl R.L., et al. Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT. J Nucl Cardiol 14 (2007) 200-206
    • (2007) J Nucl Cardiol , vol.14 , pp. 200-206
    • Goetze, S.1    Wahl, R.L.2
  • 2
    • 0036657431 scopus 로고    scopus 로고
    • A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models
    • O'Connor M.K., Kemp B., Anstett F., Christian P., Ficaro E.P., Frey E., et al. A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models. J Nucl Card 9 (2002) 361-376
    • (2002) J Nucl Card , vol.9 , pp. 361-376
    • O'Connor, M.K.1    Kemp, B.2    Anstett, F.3    Christian, P.4    Ficaro, E.P.5    Frey, E.6
  • 3
    • 23244444921 scopus 로고    scopus 로고
    • Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation
    • Masood Y., Liu Y.H., DePuey G., et al. Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation. J Nucl Cardiol 12 (2005) 676-686
    • (2005) J Nucl Cardiol , vol.12 , pp. 676-686
    • Masood, Y.1    Liu, Y.H.2    DePuey, G.3
  • 4
    • 0037655094 scopus 로고    scopus 로고
    • Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
    • Beyer T., Antoch G., Blodgett T., Freudenberg L.F., Akhurst T., and Mueller S. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med Mol Imaging 30 (2003) 588-596
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 588-596
    • Beyer, T.1    Antoch, G.2    Blodgett, T.3    Freudenberg, L.F.4    Akhurst, T.5    Mueller, S.6
  • 5
    • 0037369944 scopus 로고    scopus 로고
    • Respiration-induced attenuation artifact at PET/CT: technical considerations
    • Goerres G.W., Burger C., Kamel E., Seifert B., Kaim A.H., Buck A., et al. Respiration-induced attenuation artifact at PET/CT: technical considerations. Radiology 226 (2003) 906-910
    • (2003) Radiology , vol.226 , pp. 906-910
    • Goerres, G.W.1    Burger, C.2    Kamel, E.3    Seifert, B.4    Kaim, A.H.5    Buck, A.6
  • 6
    • 0037884881 scopus 로고    scopus 로고
    • Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    • Osman M.M., Cohade C., Nakamoto Y., and Wahl R.L. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT. Eur J Nucl Med Mol Imaging 30 (2003) 603-606
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 603-606
    • Osman, M.M.1    Cohade, C.2    Nakamoto, Y.3    Wahl, R.L.4
  • 9
    • 15744374529 scopus 로고    scopus 로고
    • Attenuation correction of myocardial SPECT studies using low resolution computed tomography images
    • Tonge C.M., Manoharan M., Lawson R.S., Shields R.A., and Prescott M.C. Attenuation correction of myocardial SPECT studies using low resolution computed tomography images. Nucl Med Commun 26 (2005) 231-237
    • (2005) Nucl Med Commun , vol.26 , pp. 231-237
    • Tonge, C.M.1    Manoharan, M.2    Lawson, R.S.3    Shields, R.A.4    Prescott, M.C.5
  • 10
    • 16544386152 scopus 로고    scopus 로고
    • A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps
    • Fricke H., Fricke E., Weise R., Kammeier A., Lindner O., and Burchert W. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps. J Nucl Med 45 (2004) 1619-1625
    • (2004) J Nucl Med , vol.45 , pp. 1619-1625
    • Fricke, H.1    Fricke, E.2    Weise, R.3    Kammeier, A.4    Lindner, O.5    Burchert, W.6
  • 11
    • 0029069659 scopus 로고
    • Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact
    • DePuey E.G., and Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 36 (1995) 952-955
    • (1995) J Nucl Med , vol.36 , pp. 952-955
    • DePuey, E.G.1    Rozanski, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.