Volumn 83, Issue 4, 2007, Pages 1530-1532

Drug-Eluting Stent-Induced Left Anterior Descending Coronary Artery Aneurysm: Repair by Pericardial Patch-Where Are We Headed?

Author keywords

[No Author keywords available]

Indexed keywords

ANTITHROMBOCYTIC AGENT; RAPAMYCIN;

EID: 33947313565     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2006.12.060     Document Type: Article
Times cited : (18)

References (7)
  • 1
    • 33646229771 scopus 로고    scopus 로고
    • Drug-eluting stents and late adverse clinical outcomes. Lessons learned, lessons awaited
    • Tsimikas S. Drug-eluting stents and late adverse clinical outcomes. Lessons learned, lessons awaited. J Am Coll Cardiol 47 (2006) 2112-2115
    • (2006) J Am Coll Cardiol , vol.47 , pp. 2112-2115
    • Tsimikas, S.1
  • 2
    • 33947329711 scopus 로고    scopus 로고
    • US Food and Drug Administration. FDA advises physicians of adverse events associated with Cordis Cypher coronary stent. T03-71, October 29, 2003. Available at: www.fda.gov/bbs/topics/ANSWERS/2003/ANS01257.html. Accessed Nov 4, 2006.
  • 3
    • 4143096183 scopus 로고    scopus 로고
    • A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
    • Babapulle M.N., Joseph L., Belisle P., Brophy J.M., and Eisenberg M.J. A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents. Lancet 364 (2004) 583-591
    • (2004) Lancet , vol.364 , pp. 583-591
    • Babapulle, M.N.1    Joseph, L.2    Belisle, P.3    Brophy, J.M.4    Eisenberg, M.J.5
  • 4
    • 33646233783 scopus 로고    scopus 로고
    • Drug eluting stents: an updated meta-analysis of randomised controlled trials
    • Roiron C., Sanchez P., Bouzamondo A., Lechat P., and Montalescot G. Drug eluting stents: an updated meta-analysis of randomised controlled trials. Heart 92 (2006) 641-649
    • (2006) Heart , vol.92 , pp. 641-649
    • Roiron, C.1    Sanchez, P.2    Bouzamondo, A.3    Lechat, P.4    Montalescot, G.5
  • 5
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
    • Virmani R., Guagliumi G., Farb A., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 109 (2004) 701-705
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 6
    • 29344432871 scopus 로고    scopus 로고
    • Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project
    • Nebeker J.R., Virmani R., Bennett C.L., et al. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project. J Am Coll Cardiol 47 (2006) 175-181
    • (2006) J Am Coll Cardiol , vol.47 , pp. 175-181
    • Nebeker, J.R.1    Virmani, R.2    Bennett, C.L.3
  • 7
    • 0037303940 scopus 로고    scopus 로고
    • Drug eluting stents: are human and animal studies comparable?
    • Virmani R., Kolodgie F.D., Farb A., et al. Drug eluting stents: are human and animal studies comparable?. Heart 89 (2003) 133-138
    • (2003) Heart , vol.89 , pp. 133-138
    • Virmani, R.1    Kolodgie, F.D.2    Farb, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.