메뉴 건너뛰기




Volumn 34, Issue 4, 2007, Pages 563-572

Simultaneous evaluation of myocardial blood flow, cardiac function and lung water content using [15O]H2O and positron emission tomography

Author keywords

Cardiac output; Lung water content; MBF; PET; Principal component analysis

Indexed keywords

WATER O 15;

EID: 33947236058     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-006-0259-3     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 15044340644 scopus 로고    scopus 로고
    • Myocardial blood flow measurement by PET: Technical aspects and clinical applications
    • Kaufmann PA, Camici PG. Myocardial blood flow measurement by PET: technical aspects and clinical applications. J Nucl Med 2005;46(1):75-88.
    • (2005) J Nucl Med , vol.46 , Issue.1 , pp. 75-88
    • Kaufmann, P.A.1    Camici, P.G.2
  • 2
    • 4243125329 scopus 로고    scopus 로고
    • Positron emission tomography for quantitation of myocardial perfusion
    • Rimoldi OE, Camici PG. Positron emission tomography for quantitation of myocardial perfusion. J Nucl Cardiol 2004;11(4):482-90.
    • (2004) J Nucl Cardiol , vol.11 , Issue.4 , pp. 482-490
    • Rimoldi, O.E.1    Camici, P.G.2
  • 3
    • 9144224802 scopus 로고    scopus 로고
    • Myocardial perfusion reserve and peripheral endothelial function in patients with idiopathic dilated cardiomyopathy
    • Jan
    • Stolen KQ, Kemppainen J, Kalliokoski KK, Hallsten K, Luotolahti M, Karanko H, et al. Myocardial perfusion reserve and peripheral endothelial function in patients with idiopathic dilated cardiomyopathy. Am J Cardiol 2004;93(1):64-8. Jan.
    • (2004) Am J Cardiol , vol.93 , Issue.1 , pp. 64-68
    • Stolen, K.Q.1    Kemppainen, J.2    Kalliokoski, K.K.3    Hallsten, K.4    Luotolahti, M.5    Karanko, H.6
  • 5
    • 0034997289 scopus 로고    scopus 로고
    • Quantification of regional myocardial blood flow using dynamic H2(15)O PET and factor analysis
    • Ahn JY, Lee DS, Lee JS, Kim SK, Cheon GJ, Yeo JS, et al. Quantification of regional myocardial blood flow using dynamic H2(15)O PET and factor analysis. J Nucl Med 2001;42(5):782-7.
    • (2001) J Nucl Med , vol.42 , Issue.5 , pp. 782-787
    • Ahn, J.Y.1    Lee, D.S.2    Lee, J.S.3    Kim, S.K.4    Cheon, G.J.5    Yeo, J.S.6
  • 6
    • 0034974759 scopus 로고    scopus 로고
    • Blind separation of cardiac components and extraction of input function from H(2)(15)O dynamic myocardial PET using independent component analysis
    • Lee JS, Lee DS, Ahn JY, Cheon GJ, Kim SK, Yeo JS, et al. Blind separation of cardiac components and extraction of input function from H(2)(15)O dynamic myocardial PET using independent component analysis. J Nucl Med 2001;42(6):938-43.
    • (2001) J Nucl Med , vol.42 , Issue.6 , pp. 938-943
    • Lee, J.S.1    Lee, D.S.2    Ahn, J.Y.3    Cheon, G.J.4    Kim, S.K.5    Yeo, J.S.6
  • 7
    • 0031663697 scopus 로고    scopus 로고
    • Generation of myocardial factor images directly from the dynamic oxygen-15-water scan without use of an oxygen-15-carbon monoxide blood-pool scan
    • Hermansen F, Ashburner J, Spinks TJ, Kooner JS, Camici PG, Lammertsma AA. Generation of myocardial factor images directly from the dynamic oxygen-15-water scan without use of an oxygen-15-carbon monoxide blood-pool scan. J Nucl Med 1998;39:1696-702.
    • (1998) J Nucl Med , vol.39 , pp. 1696-1702
    • Hermansen, F.1    Ashburner, J.2    Spinks, T.J.3    Kooner, J.S.4    Camici, P.G.5    Lammertsma, A.A.6
  • 8
    • 0032973757 scopus 로고    scopus 로고
    • The measurement of lung water
    • Lange NR, Schuster DP. The measurement of lung water. Crit Care 1999;3(2):R19-24.
    • (1999) Crit Care , vol.3 , Issue.2
    • Lange, N.R.1    Schuster, D.P.2
  • 9
    • 0242409499 scopus 로고    scopus 로고
    • AMIDE: A free software tool for multimodality medical image analysis
    • Loening AM, Gambhir SS. AMIDE: a free software tool for multimodality medical image analysis. Mol Imaging 2003;2(3):131-7.
    • (2003) Mol Imaging , vol.2 , Issue.3 , pp. 131-137
    • Loening, A.M.1    Gambhir, S.S.2
  • 10
    • 0022341095 scopus 로고
    • Regional lung water and hematocrit determined by positron emission tomography
    • Schuster DP, Mintun MA, Green MA, Ter-Pogossian MM. Regional lung water and hematocrit determined by positron emission tomography. J Appl Physiol 1985;59:860-8.
    • (1985) J Appl Physiol , vol.59 , pp. 860-868
    • Schuster, D.P.1    Mintun, M.A.2    Green, M.A.3    Ter-Pogossian, M.M.4
  • 11
    • 0025778293 scopus 로고
    • Regional lung water measurements with PET: Accuracy, reproducibility, and linearity
    • Velazquez M, Haller J, Amundsen T, Schuster DP. Regional lung water measurements with PET: accuracy, reproducibility, and linearity. J Nucl Med 1991;32:719-25.
    • (1991) J Nucl Med , vol.32 , pp. 719-725
    • Velazquez, M.1    Haller, J.2    Amundsen, T.3    Schuster, D.P.4
  • 12
    • 0026767631 scopus 로고
    • Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography
    • Iida H, Rhodes C, de Silva R, Araujo LI, Bloomfield PM, Lammertsma AA, et al. Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography. J Nucl Med 1992;33:1669-77.
    • (1992) J Nucl Med , vol.33 , pp. 1669-1677
    • Iida, H.1    Rhodes, C.2    de Silva, R.3    Araujo, L.I.4    Bloomfield, P.M.5    Lammertsma, A.A.6
  • 13
    • 0023693417 scopus 로고
    • 15O and dynamic positron-emission tomography: Strategy for quantification in relation to the partial-volume effect
    • 15O and dynamic positron-emission tomography: strategy for quantification in relation to the partial-volume effect. Circulation 1988;78:104-15.
    • (1988) Circulation , vol.78 , pp. 104-115
    • Iida, H.1    Kanno, I.2    Takahashi, A.3    Miura, S.4    Murakami, M.5    Takahashi, K.6
  • 14
    • 9444224399 scopus 로고    scopus 로고
    • Measurement of cardiac output with first-pass determination during rubidium-82 PET myocardial perfusion imaging
    • Chen EQ, MacIntyre WJ, Fouad FM, Brunken RC, Go RT, Wong CO, et al. Measurement of cardiac output with first-pass determination during rubidium-82 PET myocardial perfusion imaging. Eur J Nucl Med 1996;23:993-6.
    • (1996) Eur J Nucl Med , vol.23 , pp. 993-996
    • Chen, E.Q.1    MacIntyre, W.J.2    Fouad, F.M.3    Brunken, R.C.4    Go, R.T.5    Wong, C.O.6
  • 15
    • 0037226347 scopus 로고    scopus 로고
    • Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia
    • Hove JD, Kofoed KF, Wu HM, Holm S, Friberg L, Meyer C, et al. Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia. J Nucl Cardiol 2003;10(1):28-33.
    • (2003) J Nucl Cardiol , vol.10 , Issue.1 , pp. 28-33
    • Hove, J.D.1    Kofoed, K.F.2    Wu, H.M.3    Holm, S.4    Friberg, L.5    Meyer, C.6
  • 16
    • 10844288923 scopus 로고    scopus 로고
    • Simple and accurate assessment of forward cardiac output by use of 1-(11)C-acetate PET verified in a pig model
    • Sorensen J, Stahle E, Langstrom B, Frostfeldt G, Wikstrom G, Hedenstierna G. Simple and accurate assessment of forward cardiac output by use of 1-(11)C-acetate PET verified in a pig model. J Nucl Med 2003;44(7):1176-83.
    • (2003) J Nucl Med , vol.44 , Issue.7 , pp. 1176-1183
    • Sorensen, J.1    Stahle, E.2    Langstrom, B.3    Frostfeldt, G.4    Wikstrom, G.5    Hedenstierna, G.6
  • 17
    • 12744255411 scopus 로고    scopus 로고
    • Development of myocardial microcirculation and metabolism in acute ST-elevation myocardial infarction evaluated with positron emission tomography
    • Frostfeldt G, Sorensen J, Lindahl B, Valind S, Wallentin L. Development of myocardial microcirculation and metabolism in acute ST-elevation myocardial infarction evaluated with positron emission tomography. J Nucl Cardiol 2005;12(1):43-54.
    • (2005) J Nucl Cardiol , vol.12 , Issue.1 , pp. 43-54
    • Frostfeldt, G.1    Sorensen, J.2    Lindahl, B.3    Valind, S.4    Wallentin, L.5
  • 18
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part i
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part i. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1(8476):307-10.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0035088406 scopus 로고    scopus 로고
    • Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans
    • Chareonthaitawee P, Kaufmann PA, Rimoldi O, Camici PG. Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans. Cardiovasc Res 2001;50(1):151-61.
    • (2001) Cardiovasc Res , vol.50 , Issue.1 , pp. 151-161
    • Chareonthaitawee, P.1    Kaufmann, P.A.2    Rimoldi, O.3    Camici, P.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.