메뉴 건너뛰기




Volumn 33, Issue 4, 2007, Pages 411-414

Evaluation of Efficacy of a New Custom-Made Pulse Oximeter Dental Probe in Comparison With the Electrical and Thermal Tests for Assessing Pulp Vitality

Author keywords

Pulp vitality; pulse oximeter; pulse oximeter dental sensor holder

Indexed keywords

DIAGNOSTIC AGENT;

EID: 33947133705     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2006.12.003     Document Type: Article
Times cited : (88)

References (18)
  • 1
    • 0032610851 scopus 로고    scopus 로고
    • Evaluation of a laser Doppler Flowmeter to assess blood flow in human primary incisor teeth
    • Fratkin R.D., Kenny D.J., and Johnston D.H. Evaluation of a laser Doppler Flowmeter to assess blood flow in human primary incisor teeth. Pediatr Dent 21 (1999) 53-56
    • (1999) Pediatr Dent , vol.21 , pp. 53-56
    • Fratkin, R.D.1    Kenny, D.J.2    Johnston, D.H.3
  • 2
    • 0036886131 scopus 로고    scopus 로고
    • Pulse oximetry: a diagnostic instrument in pulp vitality testing
    • Munshi A.K., Hedge A.M., and Radhakrishnan S. Pulse oximetry: a diagnostic instrument in pulp vitality testing. J Clin Pediatr Dent 26 (2002) 141-145
    • (2002) J Clin Pediatr Dent , vol.26 , pp. 141-145
    • Munshi, A.K.1    Hedge, A.M.2    Radhakrishnan, S.3
  • 4
    • 13144261736 scopus 로고    scopus 로고
    • Possible application of transmitted laser light for the assessment of human pulp vitality. Part 2. Increased laser power for enhanced detection of pulpal blood flow
    • Sasano T., Onodera D., Hashimoto K., et al. Possible application of transmitted laser light for the assessment of human pulp vitality. Part 2. Increased laser power for enhanced detection of pulpal blood flow. Dent Traumatol 21 (2005) 37-41
    • (2005) Dent Traumatol , vol.21 , pp. 37-41
    • Sasano, T.1    Onodera, D.2    Hashimoto, K.3
  • 5
    • 0032135076 scopus 로고    scopus 로고
    • Subjective sensation and objective neural discharges recorded from clinically nonvital and intact teeth
    • Ikeda H., and Suda H. Subjective sensation and objective neural discharges recorded from clinically nonvital and intact teeth. J Endod 24 (1998) 552-556
    • (1998) J Endod , vol.24 , pp. 552-556
    • Ikeda, H.1    Suda, H.2
  • 6
    • 0035317266 scopus 로고    scopus 로고
    • Efficacy of laser Doppler flowmetry for the diagnosis of revascularization of reimplanted immature dog teeth
    • Yanpiset K., Vongsavan N., Sigurdsson A., and Trope M. Efficacy of laser Doppler flowmetry for the diagnosis of revascularization of reimplanted immature dog teeth. Dent Traumatol 17 (2001) 63-70
    • (2001) Dent Traumatol , vol.17 , pp. 63-70
    • Yanpiset, K.1    Vongsavan, N.2    Sigurdsson, A.3    Trope, M.4
  • 7
    • 0026247510 scopus 로고
    • Reliability of pulpal blood flow measurements using laser Doppler flowmetry
    • Ramsay D.S., Artun J., and Martinen S.S. Reliability of pulpal blood flow measurements using laser Doppler flowmetry. J Dent Res 70 (1991) 1427-1430
    • (1991) J Dent Res , vol.70 , pp. 1427-1430
    • Ramsay, D.S.1    Artun, J.2    Martinen, S.S.3
  • 8
    • 0026672631 scopus 로고
    • Dual wavelength spectrophotometry as a diagnostic test of the pulp chamber contents
    • Nisson R., Trope M., Zhang C.D., and Chance B. Dual wavelength spectrophotometry as a diagnostic test of the pulp chamber contents. Oral Surg Oral Med Oral Pathol 74 (1992) 508-514
    • (1992) Oral Surg Oral Med Oral Pathol , vol.74 , pp. 508-514
    • Nisson, R.1    Trope, M.2    Zhang, C.D.3    Chance, B.4
  • 9
    • 0038335187 scopus 로고    scopus 로고
    • Neonatal and pediatric pulse oximetry
    • Salyer J.W. Neonatal and pediatric pulse oximetry. Respir Care 48 (2003) 386-396
    • (2003) Respir Care , vol.48 , pp. 386-396
    • Salyer, J.W.1
  • 11
    • 0035216649 scopus 로고    scopus 로고
    • Preoperative hypoxia: The clinical spectrum and current oxygen monitoring methodology
    • Wilson W.C. (Ed), WB Saunders, Philadelphia
    • Wilson W.C., and Shapiro B. Preoperative hypoxia: The clinical spectrum and current oxygen monitoring methodology. In: Wilson W.C. (Ed). Anesthesiol Clin North America: Monitoring through clinical events 19 (2001), WB Saunders, Philadelphia 799-804
    • (2001) Anesthesiol Clin North America: Monitoring through clinical events , vol.19 , pp. 799-804
    • Wilson, W.C.1    Shapiro, B.2
  • 12
    • 0033088457 scopus 로고    scopus 로고
    • Pulse oximetry evaluation of vitality in primary and immature permanent teeth
    • Goho C. Pulse oximetry evaluation of vitality in primary and immature permanent teeth. Pediatr Dent 21 (1999) 125-127
    • (1999) Pediatr Dent , vol.21 , pp. 125-127
    • Goho, C.1
  • 13
    • 0026236449 scopus 로고
    • Pulse oximeter as a diagnostic tool of pulp vitality
    • Schnettler J.M., and Wallace J.A. Pulse oximeter as a diagnostic tool of pulp vitality. J Endod 17 (1991) 488-490
    • (1991) J Endod , vol.17 , pp. 488-490
    • Schnettler, J.M.1    Wallace, J.A.2
  • 14
    • 0030098120 scopus 로고    scopus 로고
    • Evaluation of a pulse oximeter and customized probe for pulp vitality testing
    • Kahan R.S., Gulabivala K., Snook M., and Setchell D.J. Evaluation of a pulse oximeter and customized probe for pulp vitality testing. J Endod 22 (1996) 105-109
    • (1996) J Endod , vol.22 , pp. 105-109
    • Kahan, R.S.1    Gulabivala, K.2    Snook, M.3    Setchell, D.J.4
  • 15
    • 33947158006 scopus 로고    scopus 로고
    • A technology overview of the Nellcor OxiMax pulse oximeter system: 1-8. Available from www.nellcor.com.
  • 16
    • 33847654725 scopus 로고    scopus 로고
    • Assessment of the efficacy of an indigenously developed pulse oximeter dental sensor holder for pulp vitality testing-an in vivo study
    • Gopikrishna V., Kandaswamy D., and Tinagupta K. Assessment of the efficacy of an indigenously developed pulse oximeter dental sensor holder for pulp vitality testing-an in vivo study. Ind J Dent Res 17 (2006) 111-113
    • (2006) Ind J Dent Res , vol.17 , pp. 111-113
    • Gopikrishna, V.1    Kandaswamy, D.2    Tinagupta, K.3
  • 17
    • 0033145268 scopus 로고    scopus 로고
    • Evaluation of the ability of thermal and electrical tests to register pulp vitality
    • Petersson K., Soderstrom C., Kiani-Anaraki M., and Levy G. Evaluation of the ability of thermal and electrical tests to register pulp vitality. Endod Dent Traumatol 15 (1999) 127-131
    • (1999) Endod Dent Traumatol , vol.15 , pp. 127-131
    • Petersson, K.1    Soderstrom, C.2    Kiani-Anaraki, M.3    Levy, G.4
  • 18
    • 0021484547 scopus 로고
    • The predictive value of endodontic diagnostic tests
    • Hyman J.J., Cohen M.E., and Lakes G. The predictive value of endodontic diagnostic tests. Oral Surg 58 (1984) 343-346
    • (1984) Oral Surg , vol.58 , pp. 343-346
    • Hyman, J.J.1    Cohen, M.E.2    Lakes, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.