메뉴 건너뛰기




Volumn 6, Issue 3, 2006, Pages 529-534

Nanostructured polymers for detecting chemical changes during engine oil degradation

Author keywords

Engine oil degradation sensor; Mass sensitive sensors; Molecular imprinting; Total base number (TBN)

Indexed keywords

DEGRADATION; FOURIER TRANSFORM INFRARED SPECTROSCOPY; LUBRICATING OILS; NANOSTRUCTURED MATERIALS; SENSORS;

EID: 33947129151     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2006.872341     Document Type: Article
Times cited : (15)

References (16)
  • 1
    • 0006298629 scopus 로고    scopus 로고
    • Oxidation behavior of base oils and their constituting hydrocarbon types
    • H. Singh and S. Swaroop, "Oxidation behavior of base oils and their constituting hydrocarbon types," Prep. ACS, Div. Petrol. Chem., vol. 42, pp. 218-220, 1997.
    • (1997) Prep. ACS, Div. Petrol. Chem , vol.42 , pp. 218-220
    • Singh, H.1    Swaroop, S.2
  • 2
    • 0026804608 scopus 로고
    • Electrical conductivity method for evaluation of oxidative degradation of oil lubricants
    • A. Sato and T. Oshika, "Electrical conductivity method for evaluation of oxidative degradation of oil lubricants," Lubr. Eng., vol. 48, pp. 539-544, 1992.
    • (1992) Lubr. Eng , vol.48 , pp. 539-544
    • Sato, A.1    Oshika, T.2
  • 3
    • 0029277031 scopus 로고
    • Remaining useful life measurements of diesel engine oils, automotive engine oils, hydraulic fluids and greases using cyclic voltammetric methods
    • R. E. Kauffman, "Remaining useful life measurements of diesel engine oils, automotive engine oils, hydraulic fluids and greases using cyclic voltammetric methods," Lubr. Eng., vol. 51, pp. 223-229, 1995.
    • (1995) Lubr. Eng , vol.51 , pp. 223-229
    • Kauffman, R.E.1
  • 4
    • 0028425145 scopus 로고
    • In situ monitoring of high-temperature degraded engine oil with microsensors
    • H. S. Lee, S. S. Wang, D. J. Smolenski, M. B. Viola, and E. E. Klusendorf, "In situ monitoring of high-temperature degraded engine oil with microsensors," Sens. Actuators B, vol. 20, pp. 49-54, 1994.
    • (1994) Sens. Actuators B , vol.20 , pp. 49-54
    • Lee, H.S.1    Wang, S.S.2    Smolenski, D.J.3    Viola, M.B.4    Klusendorf, E.E.5
  • 5
    • 2442421099 scopus 로고    scopus 로고
    • Molecularly imprinted polymers as antibody and receptor mimics for assays, sensors and drug discovery
    • L. Ye and K. Haupt, "Molecularly imprinted polymers as antibody and receptor mimics for assays, sensors and drug discovery," Anal. Bioanal. Chem., vol. 378, pp. 1887-1897, 2004.
    • (2004) Anal. Bioanal. Chem , vol.378 , pp. 1887-1897
    • Ye, L.1    Haupt, K.2
  • 7
    • 0001664891 scopus 로고    scopus 로고
    • Quality control auf automotive engine oils with mass-sensitive chemical sensors - QCM's and molecularly imprinted polymers
    • F. L. Dickert, P. Forth, P. A. Lieberzeit, and G. Voigt, "Quality control auf automotive engine oils with mass-sensitive chemical sensors - QCM's and molecularly imprinted polymers," Fresenius J. Anal. Chem., vol. 366, pp. 802-806, 2000.
    • (2000) Fresenius J. Anal. Chem , vol.366 , pp. 802-806
    • Dickert, F.L.1    Forth, P.2    Lieberzeit, P.A.3    Voigt, G.4
  • 8
    • 0035801289 scopus 로고    scopus 로고
    • Sol-gel coated quartz crystal microbalances for monitoring automotive oil degradation
    • F. L. Dickert, W. Greibl, A. Rohrer, and G. Voigt, "Sol-gel coated quartz crystal microbalances for monitoring automotive oil degradation," Adv. Mater., vol. 13, pp. 1327-1330, 2001.
    • (2001) Adv. Mater , vol.13 , pp. 1327-1330
    • Dickert, F.L.1    Greibl, W.2    Rohrer, A.3    Voigt, G.4
  • 9
    • 3342937746 scopus 로고    scopus 로고
    • Influence of viscoelasticity and interfacial slip on acoustic waves
    • G. McHale, R. Lucklum, M. I. Newton, and J. A. Cowen, "Influence of viscoelasticity and interfacial slip on acoustic waves," J. Appl. Phys., vol. 88, pp. 7304-7312, 2000.
    • (2000) J. Appl. Phys , vol.88 , pp. 7304-7312
    • McHale, G.1    Lucklum, R.2    Newton, M.I.3    Cowen, J.A.4
  • 10
    • 0034733257 scopus 로고    scopus 로고
    • Gravimetric and non-gravimetric chemical quartz resonators
    • R. Lucklum, C. Behling, and P. Hauptmann, "Gravimetric and non-gravimetric chemical quartz resonators," Sens. Actuators B, vol. 65, pp. 277-283, 2000.
    • (2000) Sens. Actuators B , vol.65 , pp. 277-283
    • Lucklum, R.1    Behling, C.2    Hauptmann, P.3
  • 11
    • 0041667793 scopus 로고    scopus 로고
    • Measuring the swelling behavior of polymer microspheres with different cross-linking densities and the medium-dependent color changes of the resulting latex crystal films
    • X. Chen, Z. Chen, G. Lu, W. Bu, and B. Yang, "Measuring the swelling behavior of polymer microspheres with different cross-linking densities and the medium-dependent color changes of the resulting latex crystal films," J. Colloid. Interf. Sci., vol. 264, pp. 266-270, 2003.
    • (2003) J. Colloid. Interf. Sci , vol.264 , pp. 266-270
    • Chen, X.1    Chen, Z.2    Lu, G.3    Bu, W.4    Yang, B.5
  • 13
    • 33947099214 scopus 로고    scopus 로고
    • Capacitor-Comprising Device for Continuous Determination of Ferromagnetic Particles and Water Content in Lubricating Oils of Gears and Engines,
    • German Patent DE 10100773
    • A. Hovestadt and B. Hewing, "Capacitor-Comprising Device for Continuous Determination of Ferromagnetic Particles and Water Content in Lubricating Oils of Gears and Engines," German Patent DE 10100773, 2001.
    • (2001)
    • Hovestadt, A.1    Hewing, B.2
  • 14
    • 20344363391 scopus 로고    scopus 로고
    • Porogen formulations for obtaining molecularly imprinted polymers with optimized binding properties
    • R. H. Schmidt, A.-S. Belmont, and K. Haupt, "Porogen formulations for obtaining molecularly imprinted polymers with optimized binding properties," Anal. Chim. Acta, vol. 542, pp. 118-124, 2005.
    • (2005) Anal. Chim. Acta , vol.542 , pp. 118-124
    • Schmidt, R.H.1    Belmont, A.-S.2    Haupt, K.3
  • 15
    • 33947121940 scopus 로고    scopus 로고
    • Electric Capacitance-Based Sensor and Monitoring System for Detection of Trace Water and Glycols in Lubricating Oils,
    • Canadian Patent Appl. CA 2128813 AA 1990214, 1995
    • M. Schoiack and P. von der Porten, "Electric Capacitance-Based Sensor and Monitoring System for Detection of Trace Water and Glycols in Lubricating Oils," Canadian Patent Appl. CA 2128813 AA 1990214, 1995.
    • Schoiack, M.1    von der Porten, P.2
  • 16
    • 33947145924 scopus 로고    scopus 로고
    • Detection of Water in Oil,
    • European Patent Appl. EP 141636 Al 19841029, 1985
    • K. Mackie, G. K. Schleyer, and R. T. Victor, "Detection of Water in Oil," European Patent Appl. EP 141636 Al 19841029, 1985.
    • Mackie, K.1    Schleyer, G.K.2    Victor, R.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.