메뉴 건너뛰기




Volumn 14, Issue SUPPL., 2007, Pages 385-388

Study on sewage-source heat pump system using in the process of sewage treatment

Author keywords

Performance simulation; Sewage treatment; Sewage source heat pump system; Three stage spray condenser; Waste heat utilization

Indexed keywords

COMPUTER SIMULATION; ENERGY UTILIZATION; HEAT PUMP SYSTEMS; SCHEMATIC DIAGRAMS; WASTE HEAT UTILIZATION;

EID: 33847796931     PISSN: 10059113     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (7)
  • 2
    • 0021816805 scopus 로고
    • Experiences with a 3.3 Mw Heat pump using sewage water as heat source
    • Lindstrom H. O.. Experiences with a 3.3 Mw Heat pump using sewage water as heat source[J]. Journal of Heat Recovery Systems. 1985, 5(1): 33-38.
    • (1985) Journal of Heat Recovery Systems , vol.5 , Issue.1 , pp. 33-38
    • Lindstrom, H.O.1
  • 3
    • 0034942234 scopus 로고    scopus 로고
    • Reuse of heat energy in wastewater; Implementation examples in Japan
    • Funamizu N. A., Iida M., Sakakura Y., Takakuwa T.. Reuse of heat energy in wastewater; Implementation examples in Japan[J]. Water Science and Technology. 2001, 43(10): 277-285.
    • (2001) Water Science and Technology , vol.43 , Issue.10 , pp. 277-285
    • Funamizu, N.A.1    Iida, M.2    Sakakura, Y.3    Takakuwa, T.4
  • 4
    • 77950592951 scopus 로고    scopus 로고
    • China: Chemistry and industry Press
    • Qin S. J., Ye W. B.. Heat exchanger[M]. China: Chemistry and industry Press. 2002: 32-35.
    • (2002) Heat Exchanger , pp. 32-35
    • Qin, S.J.1    Ye, W.B.2
  • 6
    • 0027005074 scopus 로고
    • Three-zone steady-state modelling of a mobile air-conditioning condenser
    • Kempiak M. J., Crawford R. R.. Three-Zone Steady-State Modelling of a Mobile Air-Conditioning Condenser[J]. ASHRAE Trans. 1992, 98(2): 475-488.
    • (1992) ASHRAE Trans. , vol.98 , Issue.2 , pp. 475-488
    • Kempiak, M.J.1    Crawford, R.R.2
  • 7
    • 0034187210 scopus 로고    scopus 로고
    • Evaluation of energy use in district heating and cooling plant using sewage and one using air as heat source
    • Arashi, Norio, Inaba, Atsushi. Evaluation of energy use in district heating and cooling plant using sewage and one using air as heat source[J]. Journal of Japan Institute of Energy. 2000, 79(5): 446-454.
    • (2000) Journal of Japan Institute of Energy , vol.79 , Issue.5 , pp. 446-454
    • Arashi1    Norio2    Inaba3    Atsushi4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.