Volumn I, Issue , 2005, Pages 374-377

Automatic fluoroscopic image calibration for traumatology intervention guidance

Author keywords

Automatic calibration; Computer aided orthopaedic surgery; Distal targeting; Fluoroscopic images; Intramedullary nailing

Indexed keywords

COMPUTER AIDED DESIGN; DATA PROCESSING; FLUORESCENCE; ORTHOPEDICS; VIRTUAL REALITY;

EID: 33847789950     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/eurcon.2005.1629940     Document Type: Conference Paper
Times cited : (7)

References (9)
  • 1
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an imaging means for computerassisted surgical navigation
    • Hofstetter R., Slomczykowski M., Sati M., Nolte L.P., "Fluoroscopy as an imaging means for computerassisted surgical navigation", Computer Aided Surgery, vol. 4, no. 2, pp. 65-76, 1999.
    • (1999) Computer Aided Surgery , vol.4 , Issue.2 , pp. 65-76
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, M.3    Nolte, L.P.4
  • 2
    • 0034463546 scopus 로고    scopus 로고
    • Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants
    • Suhm N., Jacob A. L., Nolte L.-P., Regazzoni P., Messmer P., Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants, Computer Aided Surgery, vol. 5, no. 6, pp 391-400, 2000.
    • (2000) Computer Aided Surgery , vol.5 , Issue.6 , pp. 391-400
    • Suhm, N.1    Jacob, A.L.2    Nolte, L.-P.3    Regazzoni, P.4    Messmer, P.5
  • 5
    • 0025907199 scopus 로고
    • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain
    • Boone J. M., Seibert J. A., Barrett W. A., Blood E. A., Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain, Medical Physics, vol. 18, no. 2, pp. 236-242, 1991.
    • (1991) Medical Physics , vol.18 , Issue.2 , pp. 236-242
    • Boone, J.M.1    Seibert, J.A.2    Barrett, W.A.3    Blood, E.A.4
  • 6
    • 0029463591 scopus 로고
    • Correction of image intensifier distortion for 3D X-ray angiography, SPIE Medical Imaging 1995 . Physics of Medical
    • Schueler B. A., Hu X., Correction of image intensifier distortion for 3D X-ray angiography, SPIE Medical Imaging 1995 . Physics of Medical Imaging, vol. 2432, pp. 272-279, 1995.
    • (1995) Imaging , vol.2432 , pp. 272-279
    • Schueler, B.A.1    Hu, X.2
  • 7
    • 0031663998 scopus 로고    scopus 로고
    • Automated detection of BB pixel clusters in digital fluoroscopic images
    • Cho P. S., Johnson R. H., Automated detection of BB pixel clusters in digital fluoroscopic images, Physics in Medicine and Biology, vol. 43, no. 9, pp. 26772683, 1998.
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.9 , pp. 26772683
    • Cho, P.S.1    Johnson, R.H.2
  • 8
    • 0031455395 scopus 로고    scopus 로고
    • The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain
    • Gronenschild E., The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain, Medical Physics, vol. 24, no. 12, pp. 1875-1888, 1997.
    • (1997) Medical Physics , vol.24 , Issue.12 , pp. 1875-1888
    • Gronenschild, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.