메뉴 건너뛰기




Volumn 63, Issue 7, 2007, Pages 997-1007

Temperature prediction for contour-insulated concrete-filled CHS subjected to fire using large time Green's function solutions

Author keywords

Concrete filled CHS; Fire; Green's function; Insulation; Large time; Temperature

Indexed keywords

CONCRETE CONSTRUCTION; CONCRETE REINFORCEMENTS; GREEN'S FUNCTION; TEMPERATURE DISTRIBUTION; THEOREM PROVING; THERMAL EXPANSION; THERMOANALYSIS;

EID: 33847608796     PISSN: 0143974X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcsr.2006.08.014     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0033872461 scopus 로고    scopus 로고
    • A simple method for calculating the fire resistance of concrete-filled CHS columns
    • Wang Y.C. A simple method for calculating the fire resistance of concrete-filled CHS columns. Journal of Constructional Steel Research 54 (2000) 365-386
    • (2000) Journal of Constructional Steel Research , vol.54 , pp. 365-386
    • Wang, Y.C.1
  • 2
    • 0041830270 scopus 로고    scopus 로고
    • Tests and analysis on the temperature field within concrete-filled steel tubes with or without protections subjected to a standard fire
    • Han L.H., Xu L., and Zhao X.L. Tests and analysis on the temperature field within concrete-filled steel tubes with or without protections subjected to a standard fire. Advances in Structural Engineering 6 2 (2003) 121-133
    • (2003) Advances in Structural Engineering , vol.6 , Issue.2 , pp. 121-133
    • Han, L.H.1    Xu, L.2    Zhao, X.L.3
  • 3
    • 0141916370 scopus 로고    scopus 로고
    • Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard
    • Han L.H., and Huo J.S. Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard. Journal of Structural Engineering-ASCE 129 1 (2003) 68-78
    • (2003) Journal of Structural Engineering-ASCE , vol.129 , Issue.1 , pp. 68-78
    • Han, L.H.1    Huo, J.S.2
  • 4
    • 0141881836 scopus 로고    scopus 로고
    • Experimental study and calculation of fire resistance of concrete-filled steel hollow columns
    • Han L.H., Zhao X.L., Yang Y.F., and Feng J.B. Experimental study and calculation of fire resistance of concrete-filled steel hollow columns. Journal of Structural Engineering-ASCE 129 3 (2003) 346-356
    • (2003) Journal of Structural Engineering-ASCE , vol.129 , Issue.3 , pp. 346-356
    • Han, L.H.1    Zhao, X.L.2    Yang, Y.F.3    Feng, J.B.4
  • 5
    • 33847690553 scopus 로고    scopus 로고
    • Lie TT, Denham EMA. Factors affecting the fire resistance of circular hollow steel columns filled with bar-reinforced concrete. NRC-CNRC internal report no. 651. 1993
  • 6
    • 33847644849 scopus 로고    scopus 로고
    • Lie TT, Chabot M. Experimental studies on the fire resistance of hollow steel columns filled with plain concrete. NRC-CNRC internal report no. 611. 1992
  • 7
    • 33847623557 scopus 로고    scopus 로고
    • prEN 1994-1-2. Eurocode 4: Design of composite steel and concrete structures - Part 1-2: Structural rules - Structural fire design, Final draft. Brussels: CEN; 2003
  • 8
    • 33847632371 scopus 로고    scopus 로고
    • ASCE//SEI/SFPE 29-99. Standard calculation methods for structural fire protection. ASCE; 2003
  • 13
    • 21044458878 scopus 로고    scopus 로고
    • Heat transfer analysis using a Green's function approach for uniformly insulated steel members subjected to fire
    • Wang Z.H., Au S.K., and Tan K.H. Heat transfer analysis using a Green's function approach for uniformly insulated steel members subjected to fire. Engineering Structures 27 10 (2005) 1551-1562
    • (2005) Engineering Structures , vol.27 , Issue.10 , pp. 1551-1562
    • Wang, Z.H.1    Au, S.K.2    Tan, K.H.3
  • 14
    • 33746078085 scopus 로고    scopus 로고
    • Green's function solution for transient heat conduction in concrete-filled steel CHS subjected to fire
    • Wang Z.H., and Tan K.H. Green's function solution for transient heat conduction in concrete-filled steel CHS subjected to fire. Engineering Structures 28 11 (2006) 1574-1585
    • (2006) Engineering Structures , vol.28 , Issue.11 , pp. 1574-1585
    • Wang, Z.H.1    Tan, K.H.2
  • 16
    • 33847634635 scopus 로고    scopus 로고
    • Sterner E, Wickstrom U. TASEF-Temperature analysis of structures exposed to fire-User's Manual. SP report 1990: 05. Boras (Sweden): Swedish National Testing and Research Institute; 1990
  • 18
    • 0030107422 scopus 로고    scopus 로고
    • Non-linear finite element model to predict temperature histories within reinforced concrete in fires
    • Huang Z., Platten A., and Roberts J. Non-linear finite element model to predict temperature histories within reinforced concrete in fires. Building and Environment 31 2 (1996) 109-118
    • (1996) Building and Environment , vol.31 , Issue.2 , pp. 109-118
    • Huang, Z.1    Platten, A.2    Roberts, J.3
  • 19
    • 33847610952 scopus 로고    scopus 로고
    • Franssen JM, Kodur VKR, Mason J. User's manual for SAFIR 2003: A computer program for analysis of structures subjected to fire. University of Liege; 2003
  • 21
    • 33847654560 scopus 로고    scopus 로고
    • prEN 1993-1-2. Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design. Stage 49 draft. Brussels: CEN; 2003
  • 22
    • 33847641289 scopus 로고    scopus 로고
    • prEN 1991-1-2, Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire. 3rd draft. Brussels: CEN; 2001
  • 23
    • 33847684163 scopus 로고    scopus 로고
    • ISO 834. Fire resistance test-elements of building construction. International Standards Organisation; 1975


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.