메뉴 건너뛰기




Volumn 40, Issue 5, 2007, Pages 1002-1010

Mechanics of bone/PMMA composite structures: An in vitro study of human vertebrae

Author keywords

Cadaver; Cancellous bone; Cement; Human; In vitro; Kyphoplasty; Material properties; Mechanical properties; PMMA; Vertebra; Vertebroplasty

Indexed keywords

BIOMECHANICS; COMPOSITE STRUCTURES; HUMAN ENGINEERING; POLYMETHYL METHACRYLATES; STRENGTH OF MATERIALS;

EID: 33847359663     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2006.04.003     Document Type: Article
Times cited : (42)

References (14)
  • 1
    • 0032803123 scopus 로고    scopus 로고
    • An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
    • Belkoff S.M., Maroney M., Fenton D.C., and Mathis J.M. An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty. Bone 25 (1999) 23S-26S
    • (1999) Bone , vol.25
    • Belkoff, S.M.1    Maroney, M.2    Fenton, D.C.3    Mathis, J.M.4
  • 2
    • 85009195610 scopus 로고    scopus 로고
    • Mechanical properties of cortical bone and cancellous bone tissue
    • Cowin S.C. (Ed), CRC Press, Boca Raton, FL
    • Guo X.E. Mechanical properties of cortical bone and cancellous bone tissue. In: Cowin S.C. (Ed). Bone Mechanics Handbook (2001), CRC Press, Boca Raton, FL 10.1-10.23
    • (2001) Bone Mechanics Handbook
    • Guo, X.E.1
  • 3
    • 0035054442 scopus 로고    scopus 로고
    • Augmentation of mechanical properties in osteoporotic vertebral bones-a biomechanical investigation of vertebroplasty efficacy with different bone cements
    • Heini P.F., Berlemann U., Kaufmann M., Lippuner K., Fankhauser C., and van Landuy P. Augmentation of mechanical properties in osteoporotic vertebral bones-a biomechanical investigation of vertebroplasty efficacy with different bone cements. European Spine Journal 10 (2001) 164-171
    • (2001) European Spine Journal , vol.10 , pp. 164-171
    • Heini, P.F.1    Berlemann, U.2    Kaufmann, M.3    Lippuner, K.4    Fankhauser, C.5    van Landuy, P.6
  • 4
    • 33645762226 scopus 로고
    • A sharper Bonferroni procedure for multiple tests of significance
    • Hochberg Y. A sharper Bonferroni procedure for multiple tests of significance. Biometrika 75 (1988) 800-803
    • (1988) Biometrika , vol.75 , pp. 800-803
    • Hochberg, Y.1
  • 5
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects
    • Jensen M.E., Evans A.J., Mathis J.M., Kallmes D.F., Cloft H.J., and Dion J.E. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. Ajnr: American Journal of Neuroradiology 18 (1997) 1897-1904
    • (1997) Ajnr: American Journal of Neuroradiology , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3    Kallmes, D.F.4    Cloft, H.J.5    Dion, J.E.6
  • 6
    • 0026045947 scopus 로고
    • Compressive behavior of human bone-cement composites
    • Jofe M.H., Takeuchi T., and Hayes W.C. Compressive behavior of human bone-cement composites. Journal of Arthroplasty 6 (1991) 213-219
    • (1991) Journal of Arthroplasty , vol.6 , pp. 213-219
    • Jofe, M.H.1    Takeuchi, T.2    Hayes, W.C.3
  • 8
    • 0031172484 scopus 로고    scopus 로고
    • Properties of acrylic bone cement: state of the art review
    • Lewis G. Properties of acrylic bone cement: state of the art review. Journal of Biomedical Materials Research 38 (1997) 155-182
    • (1997) Journal of Biomedical Materials Research , vol.38 , pp. 155-182
    • Lewis, G.1
  • 9
    • 0035055590 scopus 로고    scopus 로고
    • Dependence of yield strain of human trabecular bone on anatomic site
    • Morgan E.F., and Keaveny T.M. Dependence of yield strain of human trabecular bone on anatomic site. Journal of Biomechanics 34 (2001) 569-577
    • (2001) Journal of Biomechanics , vol.34 , pp. 569-577
    • Morgan, E.F.1    Keaveny, T.M.2
  • 11
    • 33847380920 scopus 로고    scopus 로고
    • Race, A., Miller, M.A., Ayers, D.C., Mann, K.A., 2002. Simulation of in vivo conditions during preparation and testing of cadaveric stem/cement/femur constructs. In: Proceedings of the 15th Annual Symposium of the International Society for Technology in Arthroplasty. Oxford, England, 211p.
  • 12
    • 85130087172 scopus 로고    scopus 로고
    • Rao, R.D., Singrakhia, M.D., 2003. Painful osteoporotic vertebral fracture. Pathogenesis, evaluation, and roles of vertebroplasty and kyphoplasty in its management. Journal of Bone & Joint Surgery-American Volume 85-A, 2010-2022.
  • 13
    • 0033200346 scopus 로고    scopus 로고
    • Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
    • Tohmeh A.G., Mathis J.M., Fenton D.C., Levine A.M., and Belkoff S.M. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures. Spine 24 (1999) 1772-1776
    • (1999) Spine , vol.24 , pp. 1772-1776
    • Tohmeh, A.G.1    Mathis, J.M.2    Fenton, D.C.3    Levine, A.M.4    Belkoff, S.M.5
  • 14
    • 0024428842 scopus 로고
    • Elastic constants of composites formed from PMMA bone cement and anisotropic bovine tibial cancellous bone
    • Williams J.L., and Johnson W.J. Elastic constants of composites formed from PMMA bone cement and anisotropic bovine tibial cancellous bone. Journal of Biomechanics 22 (1989) 673-682
    • (1989) Journal of Biomechanics , vol.22 , pp. 673-682
    • Williams, J.L.1    Johnson, W.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.