메뉴 건너뛰기




Volumn 82, Issue 3, 2007, Pages 355-356

In regard to Belkacémi and Vicini: High-dose brachytherapy using the MammoSite applicator "...Give me your hand, and let the subject see, to make them know"

Author keywords

[No Author keywords available]

Indexed keywords

BRACHYTHERAPY; BREAST CANCER; EXTERNAL BEAM RADIOTHERAPY; HUMAN; LETTER; POSTOPERATIVE CARE; PRIORITY JOURNAL; RADIATION DOSE; SKIN TOXICITY; TELANGIECTASIA;

EID: 33847354625     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.10.008     Document Type: Letter
Times cited : (4)

References (5)
  • 1
    • 33746374287 scopus 로고    scopus 로고
    • Clinical experience with the MammoSite radiation therapy system for brachytherapy of breast cancer: results from an international phase II trial
    • Niehoff P., Polgár C.S., Kovács G., et al. Clinical experience with the MammoSite radiation therapy system for brachytherapy of breast cancer: results from an international phase II trial. Radiother Oncol 79 (2006) 316-320
    • (2006) Radiother Oncol , vol.79 , pp. 316-320
    • Niehoff, P.1    Polgár, C.S.2    Kovács, G.3
  • 2
    • 33646251219 scopus 로고    scopus 로고
    • Thirty-nine month results with the MammoSite brachytherapy applicator: details regarding cosmesis, toxicity and local control in partial breast irradiation
    • [Abstract]
    • Keisch M., Vicini F., Scroggins T., et al. Thirty-nine month results with the MammoSite brachytherapy applicator: details regarding cosmesis, toxicity and local control in partial breast irradiation. Proc Int J Radiat Oncol Biol 63 (2005) 10 [Abstract]
    • (2005) Proc Int J Radiat Oncol Biol , vol.63 , pp. 10
    • Keisch, M.1    Vicini, F.2    Scroggins, T.3
  • 3
    • 0025302171 scopus 로고
    • The skin-source measuring bridge. A method to avoid radiation teleangiectasia in the skin after interstitial implants for breast cancer
    • Van Limbergen E., Briot E., and Drijkoningen M. The skin-source measuring bridge. A method to avoid radiation teleangiectasia in the skin after interstitial implants for breast cancer. Int J Radiat Oncol Biol Phys 18 (1990) 1239-1244
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 1239-1244
    • Van Limbergen, E.1    Briot, E.2    Drijkoningen, M.3
  • 4
    • 14844303795 scopus 로고    scopus 로고
    • The use of the source-skin distance measuring bridge indeed reduces skin teleangiectasia after interstitial boost in breast conserving therapy
    • Georg P., Georg D., and Van Limbergen E. The use of the source-skin distance measuring bridge indeed reduces skin teleangiectasia after interstitial boost in breast conserving therapy. Radiother Oncol 74 (2005) 323-330
    • (2005) Radiother Oncol , vol.74 , pp. 323-330
    • Georg, P.1    Georg, D.2    Van Limbergen, E.3
  • 5
    • 0021260046 scopus 로고
    • The influence of fraction size in radiotherapy on the late normal tissue reaction (I + II)
    • Turesson I., and Notter G. The influence of fraction size in radiotherapy on the late normal tissue reaction (I + II). Int J Radiat Oncol Biol Phys 10 (1984) 593-606
    • (1984) Int J Radiat Oncol Biol Phys , vol.10 , pp. 593-606
    • Turesson, I.1    Notter, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.