메뉴 건너뛰기




Volumn 22, Issue 5, 2006, Pages 685-693

Magnetic resonance imaging is the diagnostic tool of choice in the preoperative evaluation of patients with partial anomalous pulmonary venous return

Author keywords

Congenital heart disease; Magnetic resonance imaging; Partial anomalous pulmonary venous return

Indexed keywords

CONTRAST MEDIUM; DIAGNOSTIC AGENT; GADOLINIUM PENTETATE; GADOTERIDOL; HETEROCYCLIC COMPOUND; ORGANOMETALLIC COMPOUND;

EID: 33847309510     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-005-9070-7     Document Type: Article
Times cited : (65)

References (33)
  • 1
    • 0002175126 scopus 로고
    • Atrial septal defect and partial anomalous pulmonary venous connection
    • Kirklin JW, Barratt-Boyes BG editors, 2nd edn, New York. Churchill Linvingstone Inc, New York
    • Kirklin JW, Barratt-Boyes BG. Atrial septal defect and partial anomalous pulmonary venous connection. In: Kirklin JW, Barratt-Boyes BG editors. Cardiac Surgery 2nd edn, New York. Churchill Linvingstone Inc, New York 1993;638-640.
    • (1993) Cardiac Surgery , pp. 638-640
    • Kirklin, J.W.1    Barratt-Boyes, B.G.2
  • 2
    • 0003349471 scopus 로고    scopus 로고
    • Surgery for adults with congenital heart disease
    • Edmunds LH, Jr. New York: McGraw-Hill
    • Laks H, Marrelli D, Drinkwater DJ editors. Surgery for adults with congenital heart disease. In: Cardiac Surgery in the Adult. Edited by Edmunds LH, Jr. New York: McGraw-Hill, 1997;1366.
    • (1997) Cardiac Surgery in the Adult , pp. 1366
    • Laks, H.1    Marrelli, D.2    Drinkwater, D.J.3
  • 3
    • 0035869441 scopus 로고    scopus 로고
    • Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage
    • Ferrari VA, Scott CH, Holland GA, Axel L, St Jhon Sutton M. Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage. J Am Coll Cardiol 2001;37(4):1120-1128.
    • (2001) J Am Coll Cardiol , vol.37 , Issue.4 , pp. 1120-1128
    • Ferrari, V.A.1    Scott, C.H.2    Holland, G.A.3    Axel, L.4    St Jhon Sutton, M.5
  • 4
    • 0029112693 scopus 로고
    • Echocardiographic evaluation of partial anomalous pulmonary venous drainage
    • Wong ML, McCrindle BW, Mota C, Smallhorn JF. Echocardiographic evaluation of partial anomalous pulmonary venous drainage. J Am Coll Cardiol 1995;26(2):503-507.
    • (1995) J Am Coll Cardiol , vol.26 , Issue.2 , pp. 503-507
    • Wong, M.L.1    McCrindle, B.W.2    Mota, C.3    Smallhorn, J.F.4
  • 5
    • 0022579398 scopus 로고
    • Detection of the drainage site in anomalous pulmonary venous connection by two-dimensional Doppler color flow-mapping echocardiography
    • Satomi G, Takao A, Momma K., et al. Detection of the drainage site in anomalous pulmonary venous connection by two-dimensional Doppler color flow-mapping echocardiography. Heart Vessels 1986;2(1):41-44.
    • (1986) Heart Vessels , vol.2 , Issue.1 , pp. 41-44
    • Satomi, G.1    Takao, A.2    Momma, K.3
  • 6
    • 0031914084 scopus 로고    scopus 로고
    • Diagnosis and management of partial anomalous pulmonary venous connection. A review of 28 pediatric cases
    • Hijii T, Fukushige J, Hara T. Diagnosis and management of partial anomalous pulmonary venous connection. A review of 28 pediatric cases. Cardiology 1998;89(2):148-151.
    • (1998) Cardiology , vol.89 , Issue.2 , pp. 148-151
    • Hijii, T.1    Fukushige, J.2    Hara, T.3
  • 7
    • 0038009187 scopus 로고    scopus 로고
    • Magnetic resonance imaging of congenital heart disease in adults
    • Geva T, Sahn DJ, Powell AJ. Magnetic resonance imaging of congenital heart disease in adults. Prog Pediatr Cardiol 2003;17(1):21-39.
    • (2003) Prog Pediatr Cardiol , vol.17 , Issue.1 , pp. 21-39
    • Geva, T.1    Sahn, D.J.2    Powell, A.J.3
  • 8
    • 7744235189 scopus 로고
    • Value of MRI in the evaluation of congenital anomalies of the heart and great vessels
    • Kastler B, Livolsi A, Germain P., et al. Value of MRI in the evaluation of congenital anomalies of the heart and great vessels. J Radiol 2004;85 (10 Pt 2):1821-1850.
    • (1821) J Radiol
    • Kastler, B.1    Livolsi, A.2    Germain, P.3
  • 9
    • 0033910760 scopus 로고    scopus 로고
    • Congenital heart disease. Evaluation of anatomy and function by MRI
    • Rebergen SA, De Roos A. Congenital Heart Disease. Evaluation of Anatomy and Function by MRI. Herz 2000;25(4):365-383.
    • (2000) Herz , vol.25 , Issue.4 , pp. 365-383
    • Rebergen, S.A.1    De Roos, A.2
  • 10
    • 0037116541 scopus 로고    scopus 로고
    • Gadoliniumenhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies
    • Greil GF, Powell AJ, Gildein HP, Geva T. Gadoliniumenhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies. J Am Coll Cardiol 2002;39(2):335-341.
    • (2002) J Am Coll Cardiol , vol.39 , Issue.2 , pp. 335-341
    • Greil, G.F.1    Powell, A.J.2    Gildein, H.P.3    Geva, T.4
  • 11
    • 0026337236 scopus 로고
    • Abnormalities of the pulmonary veins-evaluation with MR imaging and comparison with cardiac angiography and echocardiography
    • Masui T, Seelos K, Kersting-Sommerhoff B, Higgins C. Abnormalities of the pulmonary veins-evaluation with MR imaging and comparison with cardiac angiography and echocardiography. Radiology 1991;181(1):645-649.
    • (1991) Radiology , vol.181 , Issue.1 , pp. 645-649
    • Masui, T.1    Seelos, K.2    Kersting-Sommerhoff, B.3    Higgins, C.4
  • 12
    • 0031894055 scopus 로고    scopus 로고
    • Anomalies of pulmonary veins: Usefulness of spin-echo and gradient-echo MR images
    • White C, Baffa J, Haney P, Campbell A, Ness Aiver M. Anomalies of pulmonary veins: usefulness of spin-echo and gradient-echo MR images. Am J Roentgenol 1998;170(5):1365-1368.
    • (1998) Am J Roentgenol , vol.170 , Issue.5 , pp. 1365-1368
    • White, C.1    Baffa, J.2    Haney, P.3    Campbell, A.4    Ness Aiver, M.5
  • 13
    • 0028271806 scopus 로고
    • Magnetic resonance angiography of congenital pulmonary vein anomalies
    • Cohen M, Hartnell G, Finn J. Magnetic resonance angiography of congenital pulmonary vein anomalies. Am Heart J 1994;127 (4 Pt 1):954-955.
    • (1994) Am Heart J , vol.127 , Issue.4 PART 1 , pp. 954-955
    • Cohen, M.1    Hartnell, G.2    Finn, J.3
  • 14
    • 0035933148 scopus 로고    scopus 로고
    • Noninvasive quantification of left-to-right shunt in pediatric patients: Phase-contrast cine magnetic resonance imaging compared with invasive oximetry
    • Beerbaum P, Korperich H, Barth P, Esdorn H, Gieseke J, Meyer H. Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry. Circulation 2001;103(20):2476-2482.
    • (2001) Circulation , vol.103 , Issue.20 , pp. 2476-2482
    • Beerbaum, P.1    Korperich, H.2    Barth, P.3    Esdorn, H.4    Gieseke, J.5    Meyer, H.6
  • 15
    • 0038201768 scopus 로고    scopus 로고
    • Comparison between phase-velocity cine magnetic resonance imaging and invasive oximetry for quantification of atrial shunts
    • A9
    • Powell AJ, Tsai-Goodman B, Prakash A, Greil GF, Geva T. Comparison between phase-velocity cine magnetic resonance imaging and invasive oximetry for quantification of atrial shunts. Am J Cardiol 2003;91(12):1523-1525, A9.
    • (2003) Am J Cardiol , vol.91 , Issue.12 , pp. 1523-1525
    • Powell, A.J.1    Tsai-Goodman, B.2    Prakash, A.3    Greil, G.F.4    Geva, T.5
  • 16
    • 0034016549 scopus 로고    scopus 로고
    • Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: In vitro and in vivo validation
    • Powell AJ, Maier SE, Chung T, Geva T. Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: in vitro and in vivo validation. Pediatr Cardiol 2000;21(2):104-110.
    • (2000) Pediatr Cardiol , vol.21 , Issue.2 , pp. 104-110
    • Powell, A.J.1    Maier, S.E.2    Chung, T.3    Geva, T.4
  • 17
    • 0026756770 scopus 로고
    • MR measurement of blood flow in the cardiovascular system
    • Mostbeck GH, Caputo GR, Higgins CB. MR measurement of blood flow in the cardiovascular system. AJR Am J Roentgenol 1992;159(3):453-461.
    • (1992) AJR Am J Roentgenol , vol.159 , Issue.3 , pp. 453-461
    • Mostbeck, G.H.1    Caputo, G.R.2    Higgins, C.B.3
  • 18
    • 0026468493 scopus 로고
    • Quantification of left to right atrial shunts with velocity-encoded cine nuclear magnetic resonance imaging
    • Brenner LD, Caputo GR, Mostbeck G., et al. Quantification of left to right atrial shunts with velocity-encoded cine nuclear magnetic resonance imaging. J Am Coll Cardiol 1992;20(5):1246-1250.
    • (1992) J Am Coll Cardiol , vol.20 , Issue.5 , pp. 1246-1250
    • Brenner, L.D.1    Caputo, G.R.2    Mostbeck, G.3
  • 19
    • 14944359147 scopus 로고    scopus 로고
    • Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: Accuracy, reproducibility and coherence study
    • Beygui F, Furber A, Delepine S., et al. Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: accuracy, reproducibility and coherence study. Int J Cardiovasc Imaging 2004;20(6):509-516.
    • (2004) Int J Cardiovasc Imaging , vol.20 , Issue.6 , pp. 509-516
    • Beygui, F.1    Furber, A.2    Delepine, S.3
  • 20
    • 0036827099 scopus 로고    scopus 로고
    • Evaluation of methods for MR imaging of human right ventricular heart volumes and mass
    • Jauhiainen T, Jarvinen VM, Hekali PE. Evaluation of methods for MR imaging of human right ventricular heart volumes and mass. Acta Radiol 2002;43(6):587-592.
    • (2002) Acta Radiol , vol.43 , Issue.6 , pp. 587-592
    • Jauhiainen, T.1    Jarvinen, V.M.2    Hekali, P.E.3
  • 21
    • 0036707979 scopus 로고    scopus 로고
    • Comparison of right ventricular volume measurement between segmented k-space gradient-echo and steady-state free precession magnetic resonance imaging
    • Alfakih K, Thiele H, Plein S, Bainbridge GJ, Ridgway JP, Sivananthan MU. Comparison of right ventricular volume measurement between segmented k-space gradient-echo and steady-state free precession magnetic resonance imaging. J Magn Reson Imaging 2002;16(3):253-258.
    • (2002) J Magn Reson Imaging , vol.16 , Issue.3 , pp. 253-258
    • Alfakih, K.1    Thiele, H.2    Plein, S.3    Bainbridge, G.J.4    Ridgway, J.P.5    Sivananthan, M.U.6
  • 22
    • 0343163497 scopus 로고
    • Shunt detection and measurement
    • Grossman W, Baim DS editors, 4th edn, Philadelphia, PA. Lea & Febiger, Philadelphia, PA
    • Grossman W. Shunt detection and measurement. In: Grossman W, Baim DS editors. Cardiac Catheterization, Angiography, and Intervention 4th edn, Philadelphia, PA. Lea & Febiger, Philadelphia, PA 1991;166-181.
    • (1991) Cardiac Catheterization, Angiography, and Intervention , pp. 166-181
    • Grossman, W.1
  • 23
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 24
    • 0023902190 scopus 로고
    • Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect
    • Dittmann H, Jacksch R, Voelker W, Karsch KR, Seipel L. Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect. J Am Coll Cardiol 1988;11(2):338-342.
    • (1988) J Am Coll Cardiol , vol.11 , Issue.2 , pp. 338-342
    • Dittmann, H.1    Jacksch, R.2    Voelker, W.3    Karsch, K.R.4    Seipel, L.5
  • 25
    • 0021324394 scopus 로고
    • Noninvasive evaluation of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography
    • Kitabatake A, Inoue M, Asao M., et al. Noninvasive evaluation of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography. Circulation 1984;69(1):73-79.
    • (1984) Circulation , vol.69 , Issue.1 , pp. 73-79
    • Kitabatake, A.1    Inoue, M.2    Asao, M.3
  • 26
    • 0019726096 scopus 로고
    • Echocardiographic assessment of Qp/Qs in children with atrial septal defect or partial anomalous pulmonary venous connection
    • Ueda T, Uesaka K, Sono K., et al. Echocardiographic assessment of Qp/Qs in children with atrial septal defect or partial anomalous pulmonary venous connection. Jpn Circ J 1981;45(6):639-645.
    • (1981) Jpn Circ J , vol.45 , Issue.6 , pp. 639-645
    • Ueda, T.1    Uesaka, K.2    Sono, K.3
  • 27
    • 0021741349 scopus 로고
    • Noninvasive determination of the ratio of pulmonary to systemic blood flow with two-dimensional Doppler echocardiography: Efficacy and limitation
    • Okamoto M, Miyatake K, Kinoshita N., et al. Noninvasive determination of the ratio of pulmonary to systemic blood flow with two-dimensional Doppler echocardiography: efficacy and limitation. J Cardiogr 1984;14(1):189-200.
    • (1984) J Cardiogr , vol.14 , Issue.1 , pp. 189-200
    • Okamoto, M.1    Miyatake, K.2    Kinoshita, N.3
  • 28
    • 0031613230 scopus 로고    scopus 로고
    • Quantification of left-to-rightshuntinatrial septal defectu singoximetry, isotopes, and Dopplerechocardiography. Isthereamethodof reference?
    • Evangelista A, Aguade S, Candell-Riera J., et al. Quantification of left-to-rightshuntinatrial septal defectu singoximetry, isotopes, and Dopplerechocardiography. Isthereamethodof reference?. Rev Esp Cardiol 1998;51 (Suppl 1):2-9.
    • (1998) Rev Esp Cardiol , vol.51 , Issue.SUPPL. 1 , pp. 2-9
    • Evangelista, A.1    Aguade, S.2    Candell-Riera, J.3
  • 29
    • 0018946124 scopus 로고
    • Blood oxygen measurements in the assessment of intracardiac left to right shunts: A critical appraisal of methodology
    • Antman EM, Marsh JD, Green LH, Grossman W. Blood oxygen measurements in the assessment of intracardiac left to right shunts: a critical appraisal of methodology. Am J Cardiol 1980;46(2):265-271.
    • (1980) Am J Cardiol , vol.46 , Issue.2 , pp. 265-271
    • Antman, E.M.1    Marsh, J.D.2    Green, L.H.3    Grossman, W.4
  • 30
    • 0018703903 scopus 로고
    • Oximetric detection of intracardiac left-to-right shunts
    • Freed MD, Miettinen OS, Nadas AS. Oximetric detection of intracardiac left-to-right shunts. Br Heart J 1979;42(6):690-694.
    • (1979) Br Heart J , vol.42 , Issue.6 , pp. 690-694
    • Freed, M.D.1    Miettinen, O.S.2    Nadas, A.S.3
  • 31
    • 0002085408 scopus 로고
    • The oxygen saturation of blood in the venea cavae, right-heart chambers, and pulmonary vessels of healthy subjects
    • Baratt-Boyes BG, Woof EH. The oxygen saturation of blood in the venea cavae, right-heart chambers, and pulmonary vessels of healthy subjects. J Lab Clin med 1957;50(1):93-106.
    • (1957) J Lab Clin Med , vol.50 , Issue.1 , pp. 93-106
    • Baratt-Boyes, B.G.1    Woof, E.H.2
  • 32
    • 0022466841 scopus 로고
    • Variability of rightsided cardiac oxygen saturationsin adults with and without left-to-right intracardiac shunting
    • Hillis LD, Firth BG, Winniford MD. Variability of rightsided cardiac oxygen saturationsin adults with and without left-to-right intracardiac shunting. Am J Cardiol 1986;1;58(1):129-132.
    • (1986) Am J Cardiol , vol.58 , pp. 129-132
    • Hillis, L.D.1    Firth, B.G.2    Winniford, M.D.3
  • 33
    • 84875545800 scopus 로고    scopus 로고
    • Congenital heart disease
    • Lombardi M editor, Springer-Verlag Italia, Milan Chapter 7.7
    • Festa P. Congenital heart disease. In: Lombardi M editor. MRI of the Heart and Vessels Milan. Springer-Verlag Italia, Milan Chapter 7.7.
    • MRI of the Heart and Vessels Milan
    • Festa, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.