메뉴 건너뛰기




Volumn 90, Issue 5, 2007, Pages 48-55

Characteristics of biological tissue equivalent phantoms applied to UWB communications

Author keywords

Broadband; FD TD method; Local SAR; Tissue equivalent phantom; UWB

Indexed keywords

BANDWIDTH; DIRECTIONAL PATTERNS (ANTENNA); ELECTRIC IMPEDANCE; ELECTROMAGNETIC WAVE SCATTERING; FREQUENCY DOMAIN ANALYSIS; NATURAL FREQUENCIES; TIME DOMAIN ANALYSIS;

EID: 33847290349     PISSN: 87566621     EISSN: 15206424     Source Type: Journal    
DOI: 10.1002/ecja.20300     Document Type: Article
Times cited : (28)

References (16)
  • 1
    • 33847253687 scopus 로고    scopus 로고
    • FCC Part 15. Radio frequency devices. FCC, USA. 2003.
    • FCC Part 15. Radio frequency devices. FCC, USA. 2003.
  • 2
    • 0029207527 scopus 로고
    • EM interaction of handset antennas and a human in personal communications
    • Jensen MA, Rahmat-Samii Y. EM interaction of handset antennas and a human in personal communications. Proc IEEE 1995;83:7-17.
    • (1995) Proc IEEE , vol.83 , pp. 7-17
    • Jensen, M.A.1    Rahmat-Samii, Y.2
  • 3
    • 33847273367 scopus 로고    scopus 로고
    • Watanabe S, Takai M, Nojima T. Effects of the interaction between a human head and a hand-held portable radio on the antenna input impedance. Trans IEICE 1996;J79-B-II:557-565. (in Japanese)
    • Watanabe S, Takai M, Nojima T. Effects of the interaction between a human head and a hand-held portable radio on the antenna input impedance. Trans IEICE 1996;J79-B-II:557-565. (in Japanese)
  • 4
    • 33847264677 scopus 로고    scopus 로고
    • Nishida Y, Ohara G, Kobayashi T. The development of UWB human electromagnetic phantom. Tech Rep IEICE 2004;A-P2003-298. (in Japanese)
    • Nishida Y, Ohara G, Kobayashi T. The development of UWB human electromagnetic phantom. Tech Rep IEICE 2004;A-P2003-298. (in Japanese)
  • 5
    • 33847278136 scopus 로고    scopus 로고
    • IECTCI06 PT62209 Part 2 (draft).
    • IECTCI06 PT62209 Part 2 (draft).
  • 6
    • 33847308388 scopus 로고    scopus 로고
    • Ishido R, Onishi T, Saito K, Uebayashi S, Ito K. A study in the solid phantom for 3-6 GHz and evaluation of SAR distribution based on the thermographic method. EMC'04, 3B3-2, Sendai.
    • Ishido R, Onishi T, Saito K, Uebayashi S, Ito K. A study in the solid phantom for 3-6 GHz and evaluation of SAR distribution based on the thermographic method. EMC'04, 3B3-2, Sendai.
  • 7
    • 33847333559 scopus 로고    scopus 로고
    • Ishido R, Onishi T, Saito K, Uebayashi S, Ito K. A study of biological tissue-equivalent phantom for 3-6 GHz and the SAR measurement. Tech Rep IEICE 2004;A-P2003-299. (in Japanese)
    • Ishido R, Onishi T, Saito K, Uebayashi S, Ito K. A study of biological tissue-equivalent phantom for 3-6 GHz and the SAR measurement. Tech Rep IEICE 2004;A-P2003-299. (in Japanese)
  • 9
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 1996;41:2251-2269.
    • (1996) Phys Med Biol , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 10
    • 33847261332 scopus 로고    scopus 로고
    • Association of Radio Industries and Businesses Standard. Specific absorption rate standard measurement method for portable wireless devices and terminals. ARIB STD-T56, Version 2.0, 2002, in Japanese
    • Association of Radio Industries and Businesses Standard. Specific absorption rate standard measurement method for portable wireless devices and terminals. ARIB STD-T56, Version 2.0, 2002. (in Japanese)
  • 11
    • 33847314892 scopus 로고    scopus 로고
    • Ito K, Furuya K, Okano Y, Hamada L. Development and the characteristics of a biological tissue-equivalent phantom for microwaves. Trans IEICE 1998;J81-B-II:1126-1135. (in Japanese)
    • Ito K, Furuya K, Okano Y, Hamada L. Development and the characteristics of a biological tissue-equivalent phantom for microwaves. Trans IEICE 1998;J81-B-II:1126-1135. (in Japanese)
  • 12
    • 33847280695 scopus 로고    scopus 로고
    • Ito K, Kawai H, Saito K. State of the art and future prospects of biological tissue-equivalent phantoms. Trans IEICE 2002;J85-B:582-596. (in Japanese)
    • Ito K, Kawai H, Saito K. State of the art and future prospects of biological tissue-equivalent phantoms. Trans IEICE 2002;J85-B:582-596. (in Japanese)
  • 13
    • 84894021661 scopus 로고
    • Numerical solution of initial boundary value problems involving Maxwell's equation in isotropic media
    • Yee KS. Numerical solution of initial boundary value problems involving Maxwell's equation in isotropic media. IEEE Trans Antennas Propag 1966; 14:302-307.
    • (1966) IEEE Trans Antennas Propag , vol.14 , pp. 302-307
    • Yee, K.S.1
  • 14
    • 28044459877 scopus 로고
    • A perfect matched layer for the absorption of electromagnetic waves
    • Berenger J-P. A perfect matched layer for the absorption of electromagnetic waves. J Comput Phys 1994; 114:185-200.
    • (1994) J Comput Phys , vol.114 , pp. 185-200
    • Berenger, J.-P.1
  • 15
    • 33847305227 scopus 로고    scopus 로고
    • COST244 WG3. Proposal for numerical canonical models in mobile communications. Proc COST244, p 1-7, Rome, 1994.
    • COST244 WG3. Proposal for numerical canonical models in mobile communications. Proc COST244, p 1-7, Rome, 1994.
  • 16
    • 33847330930 scopus 로고    scopus 로고
    • Kawai H, Yoshimura H, Ito K. Effects of inaccurate electric constants of the tissue-equivalent phantom on the local SAR and the SAR distribution. Trans IEICE 2002;J85-B:619-630. (in Japanese)
    • Kawai H, Yoshimura H, Ito K. Effects of inaccurate electric constants of the tissue-equivalent phantom on the local SAR and the SAR distribution. Trans IEICE 2002;J85-B:619-630. (in Japanese)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.