메뉴 건너뛰기




Volumn 60, Issue 6, 2006, Pages 337-342

Profiling of metal ions leached from pharmaceutical packaging materials

Author keywords

HDPE; Inorganic leachable; LDPE; Metal ions; PET; SiO 2 coated glass; Type I glass

Indexed keywords

EXCIPIENT; GLASS; ION; METAL; PLASTIC; SOLVENT;

EID: 33847287881     PISSN: 10797440     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 0035859990 scopus 로고    scopus 로고
    • Evaluation of model solvent systems for assessing the accumulation of container extractables in drug formulations
    • Jenke, D. R. Evaluation of model solvent systems for assessing the accumulation of container extractables in drug formulations. Int. J. Pharm. 2001, 224, 51-60.
    • (2001) Int. J. Pharm. , vol.224 , pp. 51-60
    • Jenke, D.R.1
  • 2
    • 0002719377 scopus 로고
    • HPLC and GC-MS determination of compounds released to mineral waters stored in plastic bottles of PET and PVC
    • Buiarelli, F.; Cartoni, G.; Coccioli, F. HPLC and GC-MS determination of compounds released to mineral waters stored in plastic bottles of PET and PVC. Anal. Chem. 1993, 83, 93-104.
    • (1993) Anal. Chem. , vol.83 , pp. 93-104
    • Buiarelli, F.1    Cartoni, G.2    Coccioli, F.3
  • 3
    • 0026682517 scopus 로고
    • Identification of caprolactam as a potential contaminant in parenteral solutions stored in overwrapped PVC bags
    • Ulsaker, G. A.; Teinen, G. Identification of caprolactam as a potential contaminant in parenteral solutions stored in overwrapped PVC bags. J. Pharm. Biomed. Anal. 1992, 10, 77-80.
    • (1992) J. Pharm. Biomed. Anal. , vol.10 , pp. 77-80
    • Ulsaker, G.A.1    Teinen, G.2
  • 4
    • 0022658196 scopus 로고
    • Studies on contamination of intravenous solutions from PVC-bags with dynamic headspace GC-MS and LC-diode array techniques
    • Arbin, A.; Jacobsson, S.; Hanninen, K.; Hagman, A.; Ostelius, J. Studies on contamination of intravenous solutions from PVC-bags with dynamic headspace GC-MS and LC-diode array techniques," Int. J. Pharm. 1986, 28, 211-221.
    • (1986) Int. J. Pharm. , vol.28 , pp. 211-221
    • Arbin, A.1    Jacobsson, S.2    Hanninen, K.3    Hagman, A.4    Ostelius, J.5
  • 5
    • 0024413109 scopus 로고
    • Capillary GC analysis of compounds leached into parenteral solutions packaged in plastic bags
    • Snell, R. P. Capillary GC analysis of compounds leached into parenteral solutions packaged in plastic bags. J. Chromatogr. Sci. 1989, 27, 524-528.
    • (1989) J. Chromatogr. Sci. , vol.27 , pp. 524-528
    • Snell, R.P.1
  • 6
    • 0027438218 scopus 로고
    • Determination of low levels of polymer additives migrating from polyprophylene to food simulated liquids by capillary SFC and solvent venting injection
    • Berg, B. E.; Hegna, D. R.; Orlien, N.; Greibrokk, T. Determination of low levels of polymer additives migrating from polypropylene to food simulated liquids by capillary SFC and solvent venting injection. Chromatographia 1993, 37, 271-276. (Pubitemid 23287910)
    • (1993) Chromatographia , vol.37 , Issue.5-6 , pp. 271-276
    • Berg, B.E.1    Hegna, D.R.2    Orlien, N.3    Greibrokk, T.4
  • 7
    • 2242424844 scopus 로고    scopus 로고
    • The simplest sample treatment techniques to assess the quality and safety of food packaging materials
    • Nerin, C.; Rubio, C.; Salafranca, J.; Batlle, R. The simplest sample treatment techniques to assess the quality and safety of food packaging materials. Anal. Chem. 2000, 19, 435-465.
    • (2000) Anal. Chem. , vol.19 , pp. 435-465
    • Nerin, C.1    Rubio, C.2    Salafranca, J.3    Batlle, R.4
  • 8
    • 0030511839 scopus 로고    scopus 로고
    • Analysis and evaluation of filter cartridge extractables for validation in pharmaceutical downstream processing
    • Reif, O. W.; Solkner, P.; Rupp, J. Analysis and evaluation of filter cartridge extractables for validation in pharmaceutical downstream processing. PDA J. Pharm. Sci. Technol. 1996, 50 (6), 399-410.
    • (1996) PDA J. Pharm. Sci. Technol. , vol.50 , Issue.6 , pp. 399-410
    • Reif, O.W.1    Solkner, P.2    Rupp, J.3
  • 9
    • 0023996445 scopus 로고    scopus 로고
    • Factors influencing the leaching of heavy metals from plastic materials used in the packaging of food and biomedical devices
    • Alam, M. S.; Srivastava, S. P.; Seth, P. K. Factors influencing the leaching of heavy metals from plastic materials used in the packaging of food and biomedical devices. Indian Journal of. Environmental Health 1998, 30, 131.
    • (1998) Indian Journal Of. Environmental Health , vol.30 , pp. 131
    • Alam, M.S.1    Srivastava, S.P.2    Seth, P.K.3
  • 10
    • 0014575592 scopus 로고
    • On heavy metal ions contamination from ampoule glass
    • Kassem, M. A.; Kassem, A. A.; Ammar, H. O. On heavy metal ions contamination from ampoule glass. Pharm. Acta Helv. 1969, 44, 535-540.
    • (1969) Pharm. Acta Helv. , vol.44 , pp. 535-540
    • Kassem, M.A.1    Kassem, A.A.2    Ammar, H.O.3
  • 11
    • 0031690202 scopus 로고    scopus 로고
    • Aluminum in large and small volume parenterals used in total parenteral nutrition: Response to the Food and Drug Administration notice of proposed rule by the North American Society for Pediatric Gastroenterology and Nutrition
    • Klein, G. L.; Leichtner, A. M.; Heyman, M. B. Aluminum in large and small volume parenterals used in total parenteral nutrition: Response to the Food and Drug Administration notice of proposed rule by the North American Society for Pediatric Gastroenterology and Nutrition. Journal of Pediatric Gastrointestinal Nutrition 1998, 27, 257.
    • (1998) Journal of Pediatric Gastrointestinal Nutrition , vol.27 , pp. 257
    • Klein, G.L.1    Leichtner, A.M.2    Heyman, M.B.3
  • 12
    • 0030996846 scopus 로고    scopus 로고
    • Aluminum in enteral nutrition formulas and parenteral solutions
    • Baydar, T.; Aydin, A.; Duru, S.; Isimer, A.; Sahin, G. Aluminum in enteral nutrition formulas and parenteral solutions. J. Toxicol. Clin. Toxicol. 1997, 35 (3), 277-281.
    • (1997) J. Toxicol. Clin. Toxicol. , vol.35 , Issue.3 , pp. 277-281
    • Baydar, T.1    Aydin, A.2    Duru, S.3    Isimer, A.4    Sahin, G.5
  • 13
    • 0007007376 scopus 로고
    • Autoxidation and Antioxidants
    • Swarbrick, J., Boylan, L. C., Eds.; Marcel Dekker, Inc.: New York
    • Johnson, D. M.; Gu, L. C. Autoxidation and Antioxidants. In Encyclopedia of Pharmaceutical Technology; Swarbrick, J., Boylan, L. C., Eds.; Marcel Dekker, Inc.: New York, 1988; pp 415-449.
    • (1988) Encyclopedia of Pharmaceutical Technology , pp. 415-449
    • Johnson, D.M.1    Gu, L.C.2
  • 14
    • 0345470142 scopus 로고
    • Antioxidants and chelating agents as stabilizers in liquid dosage forms
    • Lachman, L. Antioxidants and chelating agents as stabilizers in liquid dosage forms. Drug Cosmet. Ind. 1968, 146, 36-40.
    • (1968) Drug Cosmet. Ind. , vol.146 , pp. 36-40
    • Lachman, L.1
  • 15
    • 0345038981 scopus 로고
    • Critical factors in developing pharmaceutical formulations - An overview, Part II
    • Kumar, V.; Sunder, N.; Potdar, A. Critical factors in developing pharmaceutical formulations - An overview, Part II. Pharm. Technol. 1992, 16 (4), 86-92.
    • (1992) Pharm. Technol. , vol.16 , Issue.4 , pp. 86-92
    • Kumar, V.1    Sunder, N.2    Potdar, A.3
  • 16
    • 0032696983 scopus 로고    scopus 로고
    • Developing an injectable formula containing an oxygen-sensitive drug: A case study of danofloxacin injectable
    • Kasraian, K.; Kuzniar, A.; Wilson, G.; Wood, J. Developing an injectable formula containing an oxygen-sensitive drug: A case study of danofloxacin injectable. Pharm. Dev. Technol. 1999, 4 (4), 475-480.
    • (1999) Pharm. Dev. Technol. , vol.4 , Issue.4 , pp. 475-480
    • Kasraian, K.1    Kuzniar, A.2    Wilson, G.3    Wood, J.4
  • 17
    • 0036861462 scopus 로고    scopus 로고
    • Extractable/leachable substances from plastic materials used as pharmaceutical product containers/devices
    • Jenke, D. Extractable/leachable substances from plastic materials used as pharmaceutical product containers/devices. PDA J. Pharm. Sci. Technol. 2002, 56 (6), 332-371.
    • (2002) PDA J. Pharm. Sci. Technol. , vol.56 , Issue.6 , pp. 332-371
    • Jenke, D.1
  • 19
    • 0019952772 scopus 로고
    • Physiochemical stability of pharmaceutical phosphate buffer solutions. II. Complexation behavior of Al(III) with additives in phosphate buffer solutions
    • Hasegawa, K.; Hashi, K.; Okada, R. Physiochemical stability of pharmaceutical phosphate buffer solutions. II. Complexation behavior of Al(III) with additives in phosphate buffer solutions. J. Parenteral Sci. Technol. 1982, 36, 128.
    • (1982) J. Parenteral Sci. Technol. , vol.36 , pp. 128
    • Hasegawa, K.1    Hashi, K.2    Okada, R.3
  • 20
    • 0020180621 scopus 로고
    • Physiochemical stability of pharmaceutical phosphate buffer solutions. IV. Prevention of precipitation in phosphate buffer solutions
    • Hasegawa, K.; Hashi, K.; Okada, R. Physiochemical stability of pharmaceutical phosphate buffer solutions. IV. Prevention of precipitation in phosphate buffer solutions. J. Parenteral Sci. Technol. 1982, 36, 210.
    • (1982) J. Parenteral Sci. Technol. , vol.36 , pp. 210
    • Hasegawa, K.1    Hashi, K.2    Okada, R.3
  • 21
    • 0023263248 scopus 로고
    • Reduction of aluminum levels in dialysis fluids through the development and use of accurate and sensitive analytical methodology
    • McHalsky, M. L.; Rainbow, B. E.; Ericson, S. P.; Weltzer, J. A.; Ayd, S. W. Reduction of aluminum levels in dialysis fluids through the development and use of accurate and sensitive analytical methodology. J. Parenteral Sci. Technol. 1987, 41, 67.
    • (1987) J. Parenteral Sci. Technol. , vol.41 , pp. 67
    • McHalsky, M.L.1    Rainbow, B.E.2    Ericson, S.P.3    Weltzer, J.A.4    Ayd, S.W.5
  • 22
    • 0344874628 scopus 로고    scopus 로고
    • Aluminum in over-the-counter drugs: Risks outweigh benefits?
    • Reinke, C.; Breitkreutz, J.; Leuenberger, H. Aluminum in over-the-counter drugs: risks outweigh benefits? Drug Safety 2003, 26, 1011-1025.
    • (2003) Drug Safety , vol.26 , pp. 1011-1025
    • Reinke, C.1    Breitkreutz, J.2    Leuenberger, H.3
  • 23
    • 0022399283 scopus 로고
    • Aluminum toxicology and the aluminum containing medications
    • Lione, A. Aluminum toxicology and the aluminum containing medications. Pharmacol. Ther. 1985, 29, 255-285.
    • (1985) Pharmacol. Ther. , vol.29 , pp. 255-285
    • Lione, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.