-
2
-
-
33847294113
-
-
American Association of Physicists in Medicine Task Group 62, Rep. 87 Medical Physics Publishing, Madison, Wisc
-
American Association of Physicists in Medicine Task Group 62, "Diode in-vivo dosimetry for patients receiving external beam radiation therapy," Rep. 87 (Medical Physics Publishing, Madison, Wisc., 2005).
-
(2005)
Diode in-vivo dosimetry for patients receiving external beam radiation therapy
-
-
-
3
-
-
0026804696
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. I. Physical characteristics and theoretical considerations
-
A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. I. Physical characteristics and theoretical considerations," Phys. Med. Biol. 37, 1883-1900 (1992).
-
(1992)
Phys. Med. Biol
, vol.37
, pp. 1883-1900
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
4
-
-
0026793771
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. II. Properties and measurements
-
A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. II. Properties and measurements," Phys. Med. Biol. 37, 1901-1913 (1992).
-
(1992)
Phys. Med. Biol
, vol.37
, pp. 1901-1913
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
5
-
-
0036816479
-
Scintillating fiber dosimeter for radiation therapy accelerator
-
J. M. Fontbonne, G. Iltis, G. Ban, A. Battala, J. C. Vernhes, J. Tillier, N. Bellaize, C. Le Brun, B. Tamain, K. Mercier, and J. C. Motin, "Scintillating fiber dosimeter for radiation therapy accelerator," IEEE Trans. Nucl. Sci. 49, 2223-2227 (2002).
-
(2002)
IEEE Trans. Nucl. Sci
, vol.49
, pp. 2223-2227
-
-
Fontbonne, J.M.1
Iltis, G.2
Ban, G.3
Battala, A.4
Vernhes, J.C.5
Tillier, J.6
Bellaize, N.7
Le Brun, C.8
Tamain, B.9
Mercier, K.10
Motin, J.C.11
-
6
-
-
5644229769
-
Signal versus noise in fiber coupled radiation dosimeters for medical applications
-
I. Gannot, ed, Proc. SPIE
-
S. L. Law, N. Suchowerska, S. C. Fleming, A. S. Beddar, and D. R. McKenzie, "Signal versus noise in fiber coupled radiation dosimeters for medical applications," in Optical Fibers and Sensors for Medical Applications IV, I. Gannot, ed., Proc. SPIE 5317, 105-115 (2004).
-
(2004)
Optical Fibers and Sensors for Medical Applications IV
, vol.5317
, pp. 105-115
-
-
Law, S.L.1
Suchowerska, N.2
Fleming, S.C.3
Beddar, A.S.4
McKenzie, D.R.5
-
7
-
-
33846856915
-
Optical fiber design and the trapping of Cerenkov radiation
-
S. H. Law, S. C. Fleming, D. R. McKenzie, and N. Suchowerska, "Optical fiber design and the trapping of Cerenkov radiation," Appl. Opt. 45, 9151-9159 (2006).
-
(2006)
Appl. Opt
, vol.45
, pp. 9151-9159
-
-
Law, S.H.1
Fleming, S.C.2
McKenzie, D.R.3
Suchowerska, N.4
|