-
1
-
-
0037805223
-
Phalangeal osteochondroma: a cause of childhood trigger finger
-
Al-Harthy A., and Rayan G.M. Phalangeal osteochondroma: a cause of childhood trigger finger. British Journal of Plastic Surgery 56 (2003) 161-163
-
(2003)
British Journal of Plastic Surgery
, vol.56
, pp. 161-163
-
-
Al-Harthy, A.1
Rayan, G.M.2
-
2
-
-
0025980379
-
Trigger finger secondary to anomalous lumbrical insertion: a case report and review of the literature
-
Bartell T.H., and Shehadi S.I. Trigger finger secondary to anomalous lumbrical insertion: a case report and review of the literature. Plastic and Reconstructive Surgery 87 (1991) 354-357
-
(1991)
Plastic and Reconstructive Surgery
, vol.87
, pp. 354-357
-
-
Bartell, T.H.1
Shehadi, S.I.2
-
4
-
-
0023730595
-
Anatomy of the finger flexor tendon sheath and pulley system
-
Doyle J.R. Anatomy of the finger flexor tendon sheath and pulley system. Journal of Hand Surgery 13A (1998) 473-484
-
(1998)
Journal of Hand Surgery
, vol.13 A
, pp. 473-484
-
-
Doyle, J.R.1
-
5
-
-
0024306104
-
Triggering secondary to an untreated partially-cut flexor tendon
-
Frewin P.R., and Scheker L.R. Triggering secondary to an untreated partially-cut flexor tendon. Journal of Hand Surgery 14B (1989) 419-421
-
(1989)
Journal of Hand Surgery
, vol.14 B
, pp. 419-421
-
-
Frewin, P.R.1
Scheker, L.R.2
-
6
-
-
23344436999
-
A case of trigger finger following partial laceration of flexor digitorum superficialis and review of the literature
-
Fujiwara M. A case of trigger finger following partial laceration of flexor digitorum superficialis and review of the literature. Archives of Orthopaedic and Trauma Surgery 125 (2005) 430-432
-
(2005)
Archives of Orthopaedic and Trauma Surgery
, vol.125
, pp. 430-432
-
-
Fujiwara, M.1
-
8
-
-
0014757774
-
Distal profundus entrapment in rheumatoid disease
-
Helal B. Distal profundus entrapment in rheumatoid disease. Hand 2 (1970) 48-51
-
(1970)
Hand
, vol.2
, pp. 48-51
-
-
Helal, B.1
-
9
-
-
0029856471
-
Congenital triggering of the index finger at the A2 pulley
-
Hirata H., Fujisawa K., Sasaki H., Morita A., and Matsumoto M. Congenital triggering of the index finger at the A2 pulley. Journal of Hand Surgery 21B (1996) 609-611
-
(1996)
Journal of Hand Surgery
, vol.21 B
, pp. 609-611
-
-
Hirata, H.1
Fujisawa, K.2
Sasaki, H.3
Morita, A.4
Matsumoto, M.5
-
10
-
-
23944499340
-
Case of trigger finger related to an intertendenous connection between the flexor tendons
-
Kazuki K., Okada T., and Naka Y. Case of trigger finger related to an intertendenous connection between the flexor tendons. Journal of Hand Surgery 30B (2005) 513-514
-
(2005)
Journal of Hand Surgery
, vol.30 B
, pp. 513-514
-
-
Kazuki, K.1
Okada, T.2
Naka, Y.3
-
11
-
-
0022732219
-
A tendon tumour presenting as a trigger finger
-
Laing P.W. A tendon tumour presenting as a trigger finger. Journal of Hand Surgery 11B (1986) 275
-
(1986)
Journal of Hand Surgery
, vol.11 B
, pp. 275
-
-
Laing, P.W.1
-
13
-
-
33644676284
-
Report of an unusual case of trigger finger secondary to phalangeal exostosis
-
Lee S.J., and Pho R.W. Report of an unusual case of trigger finger secondary to phalangeal exostosis. Hand Surgery 10 (2005) 135-138
-
(2005)
Hand Surgery
, vol.10
, pp. 135-138
-
-
Lee, S.J.1
Pho, R.W.2
-
14
-
-
0343409457
-
Trigger wrist caused by a partial laceration of the flexor superficialis tendon of the ring finger
-
Minami A., and Ogino T. Trigger wrist caused by a partial laceration of the flexor superficialis tendon of the ring finger. Journal of Hand Surgery 11B (1986) 457-459
-
(1986)
Journal of Hand Surgery
, vol.11 B
, pp. 457-459
-
-
Minami, A.1
Ogino, T.2
-
15
-
-
0032981434
-
Feasibility of partial A2 and A4 pulley excision: effect on finger flexor tendon biomechanics
-
Mitsionis G., Bastidas J.A., Grewal R., Pfaeffle H.J., Fischer K.J., and Tomaino M.M. Feasibility of partial A2 and A4 pulley excision: effect on finger flexor tendon biomechanics. Journal of Hand Surgery 24A (1999) 310-314
-
(1999)
Journal of Hand Surgery
, vol.24 A
, pp. 310-314
-
-
Mitsionis, G.1
Bastidas, J.A.2
Grewal, R.3
Pfaeffle, H.J.4
Fischer, K.J.5
Tomaino, M.M.6
-
16
-
-
0034028875
-
Flexor tendon entrapment of the digits (trigger finger and trigger thumb)
-
Moore J.S. Flexor tendon entrapment of the digits (trigger finger and trigger thumb). Journal of Occupational and Environmental Medicine 42 (2000) 526-545
-
(2000)
Journal of Occupational and Environmental Medicine
, vol.42
, pp. 526-545
-
-
Moore, J.S.1
-
17
-
-
0021508461
-
A tendon sheath tumour presenting as trigger finger
-
Oni O.O. A tendon sheath tumour presenting as trigger finger. Journal of Hand Surgery 9B (1984) 340
-
(1984)
Journal of Hand Surgery
, vol.9 B
, pp. 340
-
-
Oni, O.O.1
-
18
-
-
0022321798
-
An unusual etiology of trigger finger: a case report
-
Rankin E.A., and Reid B. An unusual etiology of trigger finger: a case report. Journal of Hand Surgery 10B (1985) 904-905
-
(1985)
Journal of Hand Surgery
, vol.10 B
, pp. 904-905
-
-
Rankin, E.A.1
Reid, B.2
-
19
-
-
0025009184
-
Distal stenosing tenosynovitis
-
Rayan G.M. Distal stenosing tenosynovitis. Journal of Hand Surgery 15A (1990) 973-975
-
(1990)
Journal of Hand Surgery
, vol.15 A
, pp. 973-975
-
-
Rayan, G.M.1
-
21
-
-
0030452429
-
The palmar aponeurosis pulley as a cause of trigger finger. A report of two cases
-
Sherman P.J., and Lane L.B. The palmar aponeurosis pulley as a cause of trigger finger. A report of two cases. Journal of Bone and Joint Surgery 78A (1996) 1753-1754
-
(1996)
Journal of Bone and Joint Surgery
, vol.78 A
, pp. 1753-1754
-
-
Sherman, P.J.1
Lane, L.B.2
-
23
-
-
0025009042
-
Trigger finger secondary to soft tissue chondroma
-
Stockley I., and Norris S.H. Trigger finger secondary to soft tissue chondroma. Journal of Hand Surgery 15B (1990) 468-469
-
(1990)
Journal of Hand Surgery
, vol.15 B
, pp. 468-469
-
-
Stockley, I.1
Norris, S.H.2
-
24
-
-
0027521422
-
Triggering of the finger secondary to partial flexor tendon tear after closed direct injury
-
Takami H., Takahashi S., and Ando M. Triggering of the finger secondary to partial flexor tendon tear after closed direct injury. Journal of Hand Surgery 18A (1993) 881-882
-
(1993)
Journal of Hand Surgery
, vol.18 A
, pp. 881-882
-
-
Takami, H.1
Takahashi, S.2
Ando, M.3
-
25
-
-
4744373479
-
The effect of partial A2 pulley excision on gliding resistance and pulley strength in vitro
-
Tanaka T., Amadio P.C., Zhao C., Zobitz M.E., and An K.N. The effect of partial A2 pulley excision on gliding resistance and pulley strength in vitro. Journal of Hand Surgery 29A (2004) 877-883
-
(2004)
Journal of Hand Surgery
, vol.29 A
, pp. 877-883
-
-
Tanaka, T.1
Amadio, P.C.2
Zhao, C.3
Zobitz, M.E.4
An, K.N.5
-
26
-
-
0029057775
-
An anatomical study of the mechanical interactions of flexor digitorum superficialis and profundus and the flexor tendon sheath in zone 2
-
Walbeehm E.T., and McGrouther D.A. An anatomical study of the mechanical interactions of flexor digitorum superficialis and profundus and the flexor tendon sheath in zone 2. Journal of Hand Surgery 20B (1995) 269-280
-
(1995)
Journal of Hand Surgery
, vol.20 B
, pp. 269-280
-
-
Walbeehm, E.T.1
McGrouther, D.A.2
|